346861693
|
0419700
|
2023-07-24
|
7167 OLD KINGS N ROAD, JACKSONVILLE, FL, 32219
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-07-25
|
Emphasis |
L: FORKLIFT, N: AMPUTATE
|
Case Closed |
2024-10-29
|
Related Activity
Type |
Complaint |
Activity Nr |
2056878 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2023-10-17 |
Abatement Due Date |
2023-12-05 |
Current Penalty |
5333.34 |
Initial Penalty |
7813.0 |
Final Order |
2023-11-16 |
Nr Instances |
2 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. At 7167 Old Kings N Road, Jacksonville, FL, on or about July 24, 2023 the employer exposed employees to potential hazardous energies in that employees were required to work on equipment to include but not limited to the American Maplan's Vacuum Chamber which had multiple energy sources such as electric and thermal, without those employees having been provided with written machine specific lock out procedure(s) to utilize to ensure that those energy sources were controlled while the employees were performing maintenance or servicing on the machine. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 II |
Issuance Date |
2023-10-17 |
Abatement Due Date |
2023-12-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-11-16 |
Nr Instances |
2 |
Nr Exposed |
9 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a. At 7167 Old Kings N Road, Jacksonville, FL, on or about July 24, 2023: the employer exposed employees to electric shock and thermal burns hazards, in that the employer's Lockout/Tagout Procedures for production line #4 did not specifically outline the rules and steps for the control the hazardous energy for equipment with more than one source of hazardous energy, such as the Krauss Maffei's Extruder, which had also thermal energy. b. At 7167 Old Kings N Road, Jacksonville, FL, on or about July 24, 2023: the employer exposed employees to electric shock and thermal burns hazards, in that the employer's Lockout/Tagout Procedures for production line #4 did not specifically outline the scope, purpose, rules and steps for the control of hazardous energy for equipment with more than one source of hazardous energy, such as the American Maplan's Vacuum Chamber, among other machinery. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2023-10-17 |
Abatement Due Date |
2023-12-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-11-16 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a. At 7167 Old Kings N Road, Jacksonville, FL, on or about July 24, 2023: the employer exposed employees to electric shock and thermal burns hazards, in that periodic inspections of the energy control procedures were not being conducted as required. |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19100303 F02 |
Issuance Date |
2023-10-17 |
Abatement Due Date |
2023-11-13 |
Current Penalty |
5333.33 |
Initial Penalty |
7813.0 |
Final Order |
2023-11-16 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a. At the Southwest wall of the Production building (Bld #2) located at7167 Old Kings N Road, Jacksonville, FL, on or about July 24, 2023: the employer exposed employees to electrical hazards in that the Square D Company 480-V electrical switchboard had circuit breakers in the ON position that were not marked to indicate their purpose. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2023-10-17 |
Current Penalty |
5333.33 |
Initial Penalty |
7813.0 |
Final Order |
2023-11-16 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. At the Southwest wall of the Production building (Bld #2) located at7167 Old Kings N Road, Jacksonville, FL, on or about July 24, 2023: the employer exposed employees to electrical hazards in that the Square D Company 480-V electrical switchboard had a circuit breakers in the ON position that was missing a cover. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100178 L01 I |
Issuance Date |
2023-10-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-11-16 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a. At 7167 Old Kings N Road, Jacksonville, FL, on or about July 24, 2023: the employer exposed employees to struck-by hazards, in that, forklift operators had not been trained and evaluated on the performance to ensure that they had the necessary knowledge and skills for the safe operation of the vehicle. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100303 B07 IV |
Issuance Date |
2023-10-17 |
Abatement Due Date |
2023-11-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-11-16 |
Nr Instances |
2 |
Nr Exposed |
9 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(7)(iv): There were damaged parts that adversely affected safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: a. At 7167 Old Kings N Road, Jacksonville, FL, on or about July 24, 2023: the employer exposed employees to electrical shock hazards and arc-flash hazards, in that the main power disconnect switch of the electric panel that fed the blue hammer mill was broken and the door of the panel could not effectively closed. b. At 7167 Old Kings N Road, Jacksonville, FL, on or about July 24, 2023: the employer exposed employees to electrical shock hazards, in that the main power disconnect switch for the electric panel of the vacuum tank in production line #4 was broken. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100303 G01 II |
Issuance Date |
2023-10-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-11-16 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a. At the Southwest wall of the Production building located at7167 Old Kings N Road, Jacksonville, FL, on or about July 24, 2023: the working space required in front of the Square D Company 480-V electrical switchboard was being used for storage, obstructing the access for equipment emergency shutdown, examination, adjustment, servicing or maintenance. |
|
|
340498005
|
0419700
|
2015-03-30
|
300 ALTON BOX ROAD WEST, ORANGE PARK, FL, 32073
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-04-17
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2017-06-02
|
Related Activity
Type |
Complaint |
Activity Nr |
971300 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2015-06-10 |
Current Penalty |
2820.0 |
Initial Penalty |
4900.0 |
Final Order |
2015-06-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: a. On or about March 30, 2015, at the catwalk over the machine production line, employees cleaning canisters filters were exposed to an 11 feet 6 inches fall hazard to the ground level, when the platform was not guarded with guardrail system. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100036 G02 |
Issuance Date |
2015-06-10 |
Abatement Due Date |
2015-07-07 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2015-06-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points: a. On or about March 30, 2015, on the east side of the Plant, the employer did not ensure that exit access was at least 28 inches wide exposing employees to tripping/falling and fire hazard. The exit access was reduced to a 23 inches by a metal frame from a machine. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2015-06-10 |
Abatement Due Date |
2015-08-31 |
Current Penalty |
1500.0 |
Initial Penalty |
2000.0 |
Final Order |
2015-06-24 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. On or about March 30, 2015, throughout the Plant, employees conducted repair and maintenance work on machinery such as, but not limited to, Grinder, Cincinnati Extruder, W-600 Compounder (Blender), Smoot Rotary Airlock and MWRS 212.2 Rotary Saw which are capable of storing energy, and the employer did not develop, document and utilize lockout/tagout procedures for the control of potentially hazardous energy. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I A |
Issuance Date |
2015-06-10 |
Current Penalty |
1500.0 |
Initial Penalty |
1600.0 |
Final Order |
2015-06-24 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: a. On or about March 30, 2015, in the Plant, electrician and maintenance employees conducting maintenance and repair work of the Grinder, Cincinnati Extruder, W-600 Compounder (Blender), Smoot Rotary Airlock and MWRS 212.2 Rotary Saw, had not been train by the employer to recognize hazardous energy sources and the methods for that energy isolation and control, exposing employees to electrical, thermal, caught-in and amputation hazards. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I B |
Issuance Date |
2015-06-10 |
Abatement Due Date |
2015-06-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-06-24 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: a. On or about March 30, 2015, in the Plant, affected employees such as equipment operators had not been instructed in the purpose and use of the energy control procedure. |
|
Citation ID |
01005 |
Citaton Type |
Other |
Standard Cited |
19100305 B02 I |
Issuance Date |
2015-06-10 |
Current Penalty |
0.0 |
Initial Penalty |
2000.0 |
Final Order |
2015-06-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a. On or about March 30, 2015, in Silo #2, the employer did not ensure that a plate was being installed to cover wire and wire nuts on motor. The lack of plate fails to prevent any electrical arching which would be a source of ignition exposing employees to electrical and fire hazards. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100219 F03 |
Issuance Date |
2015-06-10 |
Abatement Due Date |
2015-06-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-06-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: a. On or about March 30, 2015, in Silo #2, the employer did not ensure the chain and sprocket wheel on the smoot rotary airlock were enclosed exposing employees to crush hazards. |
|
|
338145014
|
0419700
|
2013-01-08
|
300 ALTON BOX ROAD WEST, JACKSONVILLE, FL, 32218
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2013-01-08
|
Emphasis |
L: FORKLIFT, L: HINOISE, N: DUSTEXPL
|
Case Closed |
2013-01-09
|
Related Activity
Type |
Inspection |
Activity Nr |
619279 |
Health |
Yes |
|
|
336192794
|
0419700
|
2012-09-07
|
300 ALTON BOX ROAD WEST, JACKSONVILLE, FL, 32218
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2012-09-07
|
Emphasis |
N: DUSTEXPL, L: HINOISE, L: EISAOF, L: FORKLIFT
|
Case Closed |
2013-01-03
|
Related Activity
Type |
Complaint |
Activity Nr |
543130 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100095 C01 |
Issuance Date |
2012-11-27 |
Abatement Due Date |
2012-12-21 |
Current Penalty |
1071.0 |
Initial Penalty |
1785.0 |
Final Order |
2012-12-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: a. An employee working as a grinder operator was exposed to a noise dose of 104.2%, or an equivalent dBA of 90.3 dBA, which was capable of causing permanent hearing loss. The sampling was performed for 327 minutes during one shift on September 19, 2012. The employer did not have a continuing, effective hearing conservation program. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2012-11-27 |
Abatement Due Date |
2012-12-21 |
Current Penalty |
1428.0 |
Initial Penalty |
2380.0 |
Final Order |
2012-12-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a. On or about September 7, 2012, employees that operated the powered industrial truck throughout the workplace were not provided the required training and evaluation. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2012-11-27 |
Abatement Due Date |
2012-12-21 |
Current Penalty |
1071.0 |
Initial Penalty |
1785.0 |
Final Order |
2012-12-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. On or about September 7, 2012, the employer did not develop and implement the written hazard communication program which described how requirements of 29 CFR 1910.1200(f), (g), and (h) would be met for employees who have exposure to hazardous materials such as but not limited to polyvinyl chloride resin, hydrocarbon wax, and calcium stearate. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2012-11-27 |
Abatement Due Date |
2012-12-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area: a. On or about September 7, 2012, the employer did not provide information and training to employees who have exposure to hazardous materials such as but not limited to polyvinyl chloride resin, hydrocarbon wax, and calcium stearate. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100134 C01 |
Issuance Date |
2012-11-27 |
Abatement Due Date |
2012-12-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. On or about September 7, 2012, the blending unit supervisor was required to wear a respirator and the employer did not establish and implement a written respiratory protection program that addressed the worksite-specific procedures such as but not limited to employee medical evaluation, fit testing, and training on the use, maintenance and care of the respirator. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19100134 E01 |
Issuance Date |
2012-11-27 |
Abatement Due Date |
2012-12-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. On or about September 7, 2012, an employee who was required to wear a NIOSH approved N95 dust mask respirator had not been provided with a medical evaluation prior to wearing the respirator. |
|
Citation ID |
02001C |
Citaton Type |
Other |
Standard Cited |
19100134 F01 |
Issuance Date |
2012-11-27 |
Abatement Due Date |
2012-12-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a. On or about September 7, 2012, an employee who was required to wear a NIOSH approved N95 dust mask respirator had not been fit tested prior to initial use of the respirator. |
|
Citation ID |
02001D |
Citaton Type |
Other |
Standard Cited |
19100134 K03 |
Issuance Date |
2012-11-27 |
Abatement Due Date |
2012-12-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: a. On or about September 7, 2012, an employee who was required to wear a NIOSH approved N95 dust mask respirator had not received respirator training. |
|
|