Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2016-03-10
|
Emphasis |
N: SILICA
|
Case Closed |
2016-08-23
|
Related Activity
Type |
Inspection |
Activity Nr |
1127965 |
Safety |
Yes |
|
Type |
Referral |
Activity Nr |
1069063 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100134 C01 |
Issuance Date |
2016-04-29 |
Abatement Due Date |
2016-06-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. On or about March 10, 2016, an employee was required to wear a N95 dust respirator when dry cutting a kitchen sink template in granite countertop and the employer did not establish and implement a written respiratory protection program that addressed the worksite-specific procedures such as but not limited to employee medical evaluations, fit testing, and training on the use, maintenance and care of the respirators. |
|
Citation ID |
01002A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2016-04-29 |
Abatement Due Date |
2016-06-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a. On or about March 10, 2016, the employer did not develop and implement the written hazard communication program which described hazardous materials such as but not limited to Omicron Quick Set Transparent Knife Grade Adhesives, Omicron Quick Set Transparent Flowing Adhesives, and Crystalline Silica. |
|
Citation ID |
01002B |
Citaton Type |
Other |
Standard Cited |
19101200 G01 |
Issuance Date |
2016-04-29 |
Abatement Due Date |
2016-06-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: a, On or about March 10, 2016, the employer did not have material safety data sheets for the hazardous materials such as but not limited to Omicron Quick Set Adhesives Transparent Knife Grade, Omicron Quick Set Transparent Flowing Adhesives, and Crystalline Silica. |
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-02-25
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2018-09-13
|
Related Activity
Type |
Complaint |
Activity Nr |
1060454 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1131254 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100141 D01 |
Issuance Date |
2016-04-15 |
Abatement Due Date |
2016-05-11 |
Current Penalty |
800.0 |
Initial Penalty |
1600.0 |
Final Order |
2016-05-04 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.141(d)(1): Washing facilities were not maintained in a sanitary condition: a. On or about February 25, 2016, at the front building, the lavatory designated for employee use was not maintained in good sanitary condition. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100141 D02 IV |
Issuance Date |
2016-04-15 |
Abatement Due Date |
2016-05-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-05-04 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.141(d)(2)(iv): Lavatories were not provided with individual hand towels or sections thereof, of cloth or paper, warm air blowers or clean individual sections of continuous cloth toweling: a. On or about February 25, 2016, at the front building, the lavatory used by employees was not provided with individual hand towels or sections thereof, of cloth or paper, warm air blowers or clean individual sections of continuous cloth toweling. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100178 P01 |
Issuance Date |
2016-04-15 |
Abatement Due Date |
2016-05-11 |
Current Penalty |
800.0 |
Initial Penalty |
1600.0 |
Final Order |
2016-05-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a. On or about February 25, 2016, at the fabrication shop, the Caterpillar 60 forklift being used at the site to unload granite slabs and move them inside the shop was defective and unsafe in that the backup alarm was not operational, there was an hydraulic leak on the mast and the right rear wheel was worn out and did not balance evenly with the new left rear wheel, exposing employees to struck-by hazards. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100243 C01 |
Issuance Date |
2016-04-15 |
Abatement Due Date |
2016-05-11 |
Current Penalty |
800.0 |
Initial Penalty |
1600.0 |
Final Order |
2016-05-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4): a. On or about February 25, 2016, at the fabrication shop, the Makita hand grinder with a 6 metal cutting wheel being used to cut granite slabs was missing a protective guard, exposing employees to struck-by and amputation hazards. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100305 D02 |
Issuance Date |
2016-04-15 |
Abatement Due Date |
2016-05-11 |
Current Penalty |
1400.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-05-04 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures approved for the purpose and were not dead front: a. On or about February 25, 2016, at the fabrication shop office, the main electrical panelboard did not have the dead front installed, exposing employees to electrical hazards. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2016-04-15 |
Abatement Due Date |
2016-05-11 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-05-04 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. On or about February 25, 2016, at the fabrication shop office, a flexible 110-V cord installed on the main electrical panelboard was used as a substitute for the fixed wiring, exposing employees to electrical hazards. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100133 A03 |
Issuance Date |
2016-04-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-05-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(3): The employer did not ensure that each affected employee, who wore prescription lenses while engaged in operations that involved eye hazards, used protection that incorporated the prescription in its design, or wore eye protection over the prescription glasses or protective lenses with side shields: a. On or about February 25, 2016, at the fabrication shop, an employee cutting stone with a powered tool was not wearing proper eye protection in that he was only wearing prescription glasses, exposing himself to an eye injury. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100178 L01 I |
Issuance Date |
2016-04-15 |
Abatement Due Date |
2016-05-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-05-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a. On or about February 25, 2016, at the work site, employees were not provided with training that consisted in formal instruction, practical exercises and evaluation on the operation of power industrial trucks to prevent a struck-by accident. |
|
|