Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-06-11
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-02-07
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2015-07-08 |
Abatement Due Date |
2015-07-20 |
Current Penalty |
2400.0 |
Initial Penalty |
2400.0 |
Final Order |
2015-08-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. Employees engaged in roof decking where the roof slope was 5:12, were exposed to a fall of 10 feet to the ground, in that, no fall protection method was being used, on or about 06/11/2015. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2015-07-08 |
Abatement Due Date |
2015-07-20 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2015-08-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; a. Employees were using a portable extension ladder to access the roof, in that, the ladder only extended 2 feet above the roof edge, on or about 06/11/2015. |
|
|