Search icon

SAFE ZONE, LLC - Florida Company Profile

Company Details

Entity Name: SAFE ZONE, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

SAFE ZONE, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 02 Feb 2006 (19 years ago)
Last Event: LC STMNT OF RA/RO CHG
Event Date Filed: 25 Jan 2021 (4 years ago)
Document Number: L06000012280
FEI/EIN Number 204355430

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3705-2 WESTVIEW DRIVE, NAPLES, FL, 34104, US
Mail Address: 3705-2 WESTVIEW DRIVE, NAPLES, FL, 34104, US
ZIP code: 34104
County: Collier
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
Willard Ashley E Secretary 3705-2 WESTVIEW DRIVE, NAPLES, FL, 34104
Ortwein Steve Vice President 5601 S. 122nd East Avenue, Tulsa, OK, 74146
Tinkler Robert Treasurer 5601 S. 122nd East Avenue, Tulsa, OK, 74146
NOLEN DUSTIN President 3705-2 WESTVIEW DRIVE, NAPLES, FL, 34104
BUSINESS FILINGS INCORPORATED Agent -

Events

Event Type Filed Date Value Description
LC STMNT OF RA/RO CHG 2021-01-25 - -
REGISTERED AGENT NAME CHANGED 2021-01-25 BUSINESS FILINGS INCORPORATED -
REGISTERED AGENT ADDRESS CHANGED 2021-01-25 1200 SOUTH PINE ISLAND RD, PLANTATION, FL 33324 -
CHANGE OF PRINCIPAL ADDRESS 2014-02-12 3705-2 WESTVIEW DRIVE, NAPLES, FL 34104 -
CHANGE OF MAILING ADDRESS 2014-02-12 3705-2 WESTVIEW DRIVE, NAPLES, FL 34104 -

Documents

Name Date
ANNUAL REPORT 2024-02-29
ANNUAL REPORT 2023-04-25
ANNUAL REPORT 2022-04-01
ANNUAL REPORT 2021-04-28
CORLCRACHG 2021-01-25
ANNUAL REPORT 2020-03-06
ANNUAL REPORT 2019-04-24
ANNUAL REPORT 2018-04-02
ANNUAL REPORT 2017-03-23
ANNUAL REPORT 2016-04-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345588149 0420600 2021-10-20 2109 GULF OF MEXICO DR. BUILDING 3, LONGBOAT KEY, FL, 34228
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2021-10-20
Case Closed 2022-04-18

Related Activity

Type Referral
Activity Nr 1821260
Safety Yes
339067589 0418800 2013-05-14 6190 SHIRLEY STREET, NAPLES, FL, 34109
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2013-05-14
Emphasis L: EISAOF, N: AMPUTATE, N: SSTARG12, P: SSTARG12
Case Closed 2013-07-30

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2013-07-01
Abatement Due Date 2013-07-16
Current Penalty 2100.0
Initial Penalty 3500.0
Final Order 2013-07-22
Nr Instances 3
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about May 14, 2013, at the above addressed jobsite, an employee was exposed to a caught-by hazard while working with a drill press (Central Machinery, Serial Number 0310060056) which lacked a guard on its point of operation. b) On or about May 14, 2013, at the above addressed jobsite, an employee was exposed to a caught-by hazard while working with a drill press (Delta, Model No. 17-950L) which lacked a guard on its point of operation. c) On or about May 14, 2013, at the above addressed jobsite, employees were exposed to a caught-by hazard while working with an ironworker (Piranha, Serial Number 4717) which lacked a guard on its point of operation.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 B
Issuance Date 2013-07-01
Abatement Due Date 2013-07-08
Current Penalty 1680.0
Initial Penalty 2100.0
Final Order 2013-07-22
Nr Instances 2
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) On or about May 14, 2013, at the above addressed jobsite, an employee was exposed to a struck-by hazard while working with a drill press (Central Machinery, Serial Number 0310060056) that was not anchored. b) On or about May 14, 2013, at the above addressed jobsite, an employee was exposed to a struck-by hazard while working with a bench grinder (Ryobi, Serial Number W06323) that was not anchored.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100215 A04
Issuance Date 2013-07-01
Abatement Due Date 2013-07-08
Current Penalty 1260.0
Initial Penalty 2800.0
Final Order 2013-07-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) On or about May 14, 2013, at the above addressed jobsite, an employee was exposed to a struck-by hazard while working with a bench grinder (Ryobi, Serial Number W06323) that lacked a workrest on its right side.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 2013-07-01
Abatement Due Date 2013-07-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-07-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) On or about May 14, 2013, at the above addressed jobsite, an employee was exposed to a struck-by hazard while working with a bench grinder (Ryobi, Serial Number W06323) that had its right side tongue guard placed at 1/2" from the wheel periphery.