Search icon

COVENANT CONSTRUCTION, LLC - Florida Company Profile

Company Details

Entity Name: COVENANT CONSTRUCTION, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

COVENANT CONSTRUCTION, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 20 Jun 2005 (20 years ago)
Date of dissolution: 26 Sep 2008 (17 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 26 Sep 2008 (17 years ago)
Document Number: L05000062859
FEI/EIN Number 203007842

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 512 THORNILL ROAD, FORT WALTON BEACH, FL, 32547
Mail Address: 512 THORNILL ROAD, FORT WALTON BEACH, FL, 32547
ZIP code: 32547
County: Okaloosa
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
WILDES KEITH Managing Member 512 THORNILL ROAD, FORT WALTON BEACH, FL, 32547
WILDES KEITH Agent 512 THORNILL ROAD, FORT WALTON BEACH, FL, 32547

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2008-09-26 - -

Documents

Name Date
ANNUAL REPORT 2007-02-16
ANNUAL REPORT 2006-02-15
Florida Limited Liabilites 2005-06-20

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341033454 0418800 2015-11-03 3016 S. JOG RD, GREEN ACRES, FL, 33413
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2015-11-03
Emphasis L: FALL
Case Closed 2017-03-27

Related Activity

Type Referral
Activity Nr 1034368
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2016-01-29
Current Penalty 6720.0
Initial Penalty 2800.0
Final Order 2016-03-25
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) On or about November 3, 2015, at the jobsite located at 3016 S. Jog Rd., Green Acres, FL 33413, an employee was exposed to a fall of approximately 12 feet while working from a scaffold that was not fully planked while performing plastering operations.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E09 I
Issuance Date 2016-01-29
Abatement Due Date 2016-02-10
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2016-03-25
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(9)(i): The employer did not provide safe means of access for each employee erecting or dismantling a scaffold: On or about November 3, 2015, at the jobsite located above, an employee erected a frame scaffold without safe means of access while erecting the scaffold.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2016-01-29
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2016-03-25
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: On or about November 3, 2015, at the jobsite located at 3016 S. Jog Rd, Green Acres, FL 33467, an employee was performing plastering operations without the use of fall protection or guardrails was exposed to a fall hazard of approximately 12 feet.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2016-01-29
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2016-03-25
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in. On or about November 3, 2015, at the above location 3016 S. Jog Rd, Green Acres, FL 33413, an employee was not properly trained on the erection and moving of a scaffold creating a 15 foot fall hazard for the employee working on the scaffold.