Search icon

FLORES FRAMING LLC - Florida Company Profile

Company Details

Entity Name: FLORES FRAMING LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

FLORES FRAMING LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 02 Dec 2004 (20 years ago)
Date of dissolution: 16 Sep 2005 (20 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 16 Sep 2005 (20 years ago)
Document Number: L04000086971
Address: 7825 LAUREL OAK LANE, KISSIMMEE, FL, 34747
Mail Address: P O BOX 4652, HAINES CITY, FL, 33845
ZIP code: 34747
County: Osceola
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
FLORES ANICETO Managing Member 7825 LAUREL OAK LANE, KISSIMMEE, FL, 34747
FLORES ALFREDO Agent 7825 LAUREL OAK LANE, HAINES CITY, FL, 33845
FLORES ALFREDO Managing Member 7825 LAUREL OAK LANE, KISSIMMEE, FL, 34747

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2005-09-16 - -

Documents

Name Date
Florida Limited Liability 2004-12-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339560955 0419700 2014-01-13 101A ST JOHN'S DRIVE, PANAMA CITY BEACH, FL, 32407
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-01-13
Emphasis L: FALL, P: FALL
Case Closed 2016-11-09

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260102 A01
Issuance Date 2014-01-30
Current Penalty 0.0
Initial Penalty 1600.0
Final Order 2014-07-29
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about January 13, 2014, an employee was using a Hitachi pneumatic nail gun without the use of safety glasses.
Citation ID 02001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-01-30
Current Penalty 1840.0
Initial Penalty 2800.0
Final Order 2014-07-29
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about January 13, 2014, employees setting trusses were not protected from a 20 feet fall hazard by the use of a fall protection system.
Citation ID 02002
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2014-01-30
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-07-29
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support): a. On or about January 13, 2014, on the interior east side of the building, the ladder used to access the 2nd floor was not angled correctly, exposing employees to a 10 feet fall hazard.