Search icon

NEWVILLE MASONRY LLC - Florida Company Profile

Company Details

Entity Name: NEWVILLE MASONRY LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

NEWVILLE MASONRY LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 21 May 2004 (21 years ago)
Document Number: L04000040181
FEI/EIN Number 550868856

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2121 EUGENE ST, SARASOTA, FL, 34231
Mail Address: 2121 EUGENE ST, SARASOTA, FL, 34231
ZIP code: 34231
County: Sarasota
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
NEWVILLE PATRICIA Managing Member 2121 EUGENE ST, SARASOTA, FL, 34231
NEWVILLE TIMOTHY J Agent 2121 EUGENE ST, SARASOTA, FL, 34231

Documents

Name Date
ANNUAL REPORT 2024-04-15
ANNUAL REPORT 2023-04-12
ANNUAL REPORT 2022-04-20
ANNUAL REPORT 2021-04-15
ANNUAL REPORT 2020-06-16
ANNUAL REPORT 2019-04-26
ANNUAL REPORT 2018-03-26
ANNUAL REPORT 2017-03-23
ANNUAL REPORT 2016-04-26
ANNUAL REPORT 2015-04-21

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347909657 0420600 2024-07-31 1099 BLUE SHELL LOOP LOT 152, LAKEWOOD RANCH, FL, 34240
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-07-31
Emphasis N: FALL

Related Activity

Type Referral
Activity Nr 2238385
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2024-12-26
Current Penalty 4516.4
Initial Penalty 6452.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1):Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports: a) On or about 07/31/2024, at 1099 Blue Shell Loop, Lakewood Ranch/Sarasota, Florida 34241(Lot 152), throughout the worksite, the scaffolding platforms were not fully planked, exposing employees to a 14 foot 4 inch fall hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2024-12-26
Current Penalty 4516.4
Initial Penalty 6452.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2):Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation: a) On or about 07/31/2024, at 1099 Blue Shell Loop, Lakewood Ranch/Sarasota, Florida 34241(Lot 152), throughout the worksite, the scaffolding did not have base plates, exposing employes to a scaffold collapse and a 14 foot 4 inch fall hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2024-12-26
Abatement Due Date 2025-01-23
Current Penalty 4516.4
Initial Penalty 6452.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a) On or about 07/31/2024, at 1099 Blue Shell Loop, Lakewood Ranch/Sarasota, Florida 34241(Lot 152), throughout the worksite, the scaffolding did not have an adequate ladder for safe access, exposing employees to a 14-foot 4-inch fall hazard.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2024-12-26
Current Penalty 4516.4
Initial Penalty 6452.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1):Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) On or about 07/31/2024, at 1099 Blue Shell Loop, Lakewood Ranch/Sarasota, Florida 34241(Lot 152), throughout the worksite, employees were exposed to a 14-foot 4-inch fall, in that fall protection was not utilized.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260452 C03
Issuance Date 2024-12-26
Abatement Due Date 2025-01-23
Current Penalty 4516.4
Initial Penalty 6452.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(3):Frames and panels were not joined together vertically by coupling or stacking pins or equivalent means: a) On or about 07/31/2024, at 1099 Blue Shell Loop, Lakewood Ranch/Sarasota, Florida 34241(Lot 152), throughout the worksite, the scaffolding did not have the frame sections pinned or otherwise secured, exposing employees to a scaffold collapse and a 14-foot 4-inch fall hazard.
Citation ID 01006
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2024-12-26
Abatement Due Date 2025-01-23
Current Penalty 4516.4
Initial Penalty 6452.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4):Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about 07/31/2024, at 1099 Blue Shell Loop, Lakewood Ranch/Sarasota, Florida 34241(Lot 152), the employer exposed employees to fall hazards, in that employees were improperly using A-Frame ladders in a closed position and propped up against exterior walls and scaffold while performing masonry work.
347575946 0420600 2024-06-25 1095 BLUE SHELL LOOP, LAKEWOOD RANCH, FL, 34240
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2024-06-25
Emphasis N: FALL

Related Activity

Type Inspection
Activity Nr 1792453
Safety Yes
Type Referral
Activity Nr 2178436
Safety Yes
Type Accident
Activity Nr 2178653
Type Inspection
Activity Nr 1790339
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260020 B01
Issuance Date 2024-12-23
Abatement Due Date 2025-01-21
Current Penalty 4516.4
Initial Penalty 6452.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1):The employer did not initiate and maintain such programs as may be necessary to comply with this part. a) On or about 06/25/2024, at 1095 Blue Shell Loop, Lakewood Ranch, Sarasota, Florida 34241(Lot 153), the employer did not develop and maintain a safety and health program to protect employees from fall hazards encountered at the construction site.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260050 C
Issuance Date 2024-12-23
Abatement Due Date 2025-01-21
Current Penalty 3227.0
Initial Penalty 4610.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.50(c):A person who has a valid certificate in first-aid training was not available at the worksite to render first-aid: a) On or about 06/25/2024, at 1095 Blue Shell Loop, Lakewood Ranch/Sarasota, Florida 34241(Lot 153), the employer did not ensure that accessible medical treatment was made available to an injured employee who fell 11 feet 4 inches to the lower level.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2024-12-23
Current Penalty 2580.9
Initial Penalty 3687.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a):Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 06/25/2024, at 1095 Blue Shell Loop, Sarasota, Florida 34241(Lot 153) the employer exposed employees to struck by hazards, in that a hard hat was not worn by an employee manually guiding concrete with a concrete pump hose with overhead hazards present in the form of the pump hose and boom.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2024-12-23
Current Penalty 4516.4
Initial Penalty 6452.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1):Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports: a) On or about 06/25/2024, at 1095 Blue Shell Loop, Sarasota, Florida 34241(Lot 153), throughout the worksite, the scaffolding platforms were not fully planked, exposing employees to a 10-foot 3-inch fall hazard.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2024-12-23
Current Penalty 4516.4
Initial Penalty 6452.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2):Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation: a) On or about 06/25/2024, at 1095 Blue Shell Loop, Sarasota, Florida 34241(Lot 153), throughout the worksite, the scaffolding did not have base plates, exposing employes to a scaffold collapse and a 10-foot 3-inch fall hazard.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2024-12-23
Current Penalty 4516.4
Initial Penalty 6452.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a) On or about 06/25/2024, at 1095 Blue Shell Loop, Sarasota, Florida 34241(Lot 153), throughout the worksite, the scaffolding did not have an adequate ladder for safe access, exposing employees to a 10-foot 3-inch fall hazard.
Citation ID 01007
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2024-12-23
Current Penalty 4516.4
Initial Penalty 6452.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1):Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) On or about 06/25/2024, at 1095 Blue Shell Loop, Sarasota, Florida 34241(Lot 153), throughout the worksite, the scaffolding did not have guardrails, exposing employees to a 10-foot 3-inch fall hazard.
Citation ID 01008
Citaton Type Serious
Standard Cited 19260452 C03
Issuance Date 2024-12-23
Current Penalty 4516.4
Initial Penalty 6452.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(3):Frames and panels were not joined together vertically by coupling or stacking pins or equivalent means: a) On or about 06/25/2024, at 1095 Blue Shell Loop, Sarasota, Florida 34241(Lot 153), throughout the worksite, the scaffolding did not have the frame sections pinned or otherwise secured, exposing employees to a scaffold collapse and a 10-foot 3-inch fall hazard.
Citation ID 01009
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-12-23
Current Penalty 16131.0
Initial Penalty 16131.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about 06/25/2024, at 1095 Blue Shell Loop, Sarasota, Florida 34241(Lot 153), on the North side of the house, an employee working on top of a concrete block wall was not protected from an 11-foot 4-inch fall hazard by the use of a fall protection system.
Citation ID 01010
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2024-12-23
Abatement Due Date 2025-01-21
Current Penalty 4516.4
Initial Penalty 6452.0
Final Order 2025-01-22
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1):The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about 06/25/2024, at 1095 Blue Shell Loop, Sarasota, Florida 34241(Lot 153), employees working from elevations such as on top of block walls were not trained about fall hazards and methods of protection from fall hazards.

Date of last update: 01 Apr 2025