Search icon

PRIME ELECTRIC L.L.C. - Florida Company Profile

Company Details

Entity Name: PRIME ELECTRIC L.L.C.
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

PRIME ELECTRIC L.L.C. is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 07 May 2004 (21 years ago)
Document Number: L04000037538
FEI/EIN Number 201137443

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1229 WEST MAIN ST., LEESBURG, FL, 34748
Mail Address: P.O. BOX 491576, LEESBURG, FL, 34749
ZIP code: 34748
County: Lake
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
HAMILTON WYLIE Managing Member 429 CRESTRUN LOOP, LEESBURG, FL, 34748
HAMILTON THELMA Managing Member 429 CRESTRUN LOOP, LEESBURG, FL, 34748
HAMILTON WYLIE Agent 429 CRESTRUN LOOP, LEESBURG, FL, 34748

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2009-01-26 429 CRESTRUN LOOP, LEESBURG, FL 34748 -
CHANGE OF MAILING ADDRESS 2005-04-12 1229 WEST MAIN ST., LEESBURG, FL 34748 -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J16000028112 TERMINATED 372719227751000 ORANGE COUNTY COURT 2016-01-20 2021-01-20 $2,358.64 CITY ELECTRIC SUPPLY COMPANY, 6827 NORTH ORANGE BLOSSOM TRAIL, SUITE 2, ORLANDO, FL 32810
J13001453126 TERMINATED 1000000523512 LAKE 2013-09-10 2023-10-03 $ 4,825.70 STATE OF FLORIDA, DEPARTMENT OF REVENUE, LEESBURG SERVICE CENTER, 1904 THOMAS AVE STE 103, LEESBURG FL347483289

Documents

Name Date
ANNUAL REPORT 2024-04-01
ANNUAL REPORT 2023-04-05
ANNUAL REPORT 2022-04-25
ANNUAL REPORT 2021-03-23
ANNUAL REPORT 2020-02-03
ANNUAL REPORT 2019-04-26
ANNUAL REPORT 2018-04-27
ANNUAL REPORT 2017-04-20
ANNUAL REPORT 2016-04-06
ANNUAL REPORT 2015-04-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339493892 0420600 2013-11-19 BLOOMINGDALE AVE, BRANDON, FL, 33511
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-11-19
Emphasis L: EISAOF, L: FALL, P: FALL
Case Closed 2014-02-04

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2014-01-10
Current Penalty 688.8
Initial Penalty 1148.0
Final Order 2014-01-28
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) At the site - an employee was exposed to a 12 foot fall while installing junction boxes from a scaffold platform that was missing guardrails.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2014-01-10
Current Penalty 413.4
Initial Penalty 689.0
Final Order 2014-01-28
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) At the site - scaffold was not inspected before its use to ensure it was equipped to protect employees from a potential fall hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-01-10
Current Penalty 413.4
Initial Penalty 689.0
Final Order 2014-01-28
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) At the site - the ladder used for access was not extended 3 feet above the scaffold platform.