Search icon

DECORATIVE HOME SERVICES, LLC - Florida Company Profile

Company Details

Entity Name: DECORATIVE HOME SERVICES, LLC
Jurisdiction: FLORIDA
Filing Type: Florida Limited Liability Co.

DECORATIVE HOME SERVICES, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations.
In Florida, LLCs are governed by Title XXXVI, Chapter 605, Florida Revised Limited Liability Company Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 01 Apr 2004 (21 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 27 Mar 2019 (6 years ago)
Document Number: L04000024890
FEI/EIN Number 201048191

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 6504 GRAND ESTUARY TRAIL #102, BRADENTON, FL, 34212, US
Mail Address: 6504 GRAND ESTUARY TRAIL #102, BRADENTON, FL, 34212, US
ZIP code: 34212
County: Manatee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
UNGARELLI ANTHONY Managing Member 6504 GRAND ESTUARY TRAIL #102, BRADENTON, FL, 34212
UNGARELLI BARBARA Managing Member 6504 GRAND ESTUARY TRAIL #102, BRADENTON, FL, 34212
UNGARELLI BARBARA J Agent 6504 GRAND ESTUARY TRAIL #102, BRADENTON, FL, 34212

Events

Event Type Filed Date Value Description
REINSTATEMENT 2019-03-27 - -
CHANGE OF PRINCIPAL ADDRESS 2019-03-27 6504 GRAND ESTUARY TRAIL #102, BRADENTON, FL 34212 -
CHANGE OF MAILING ADDRESS 2019-03-27 6504 GRAND ESTUARY TRAIL #102, BRADENTON, FL 34212 -
REGISTERED AGENT NAME CHANGED 2019-03-27 UNGARELLI, BARBARA J -
REGISTERED AGENT ADDRESS CHANGED 2019-03-27 6504 GRAND ESTUARY TRAIL #102, BRADENTON, FL 34212 -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2018-09-28 - -

Documents

Name Date
ANNUAL REPORT 2024-02-06
ANNUAL REPORT 2023-04-06
ANNUAL REPORT 2022-03-10
ANNUAL REPORT 2021-04-30
ANNUAL REPORT 2020-06-08
REINSTATEMENT 2019-03-27
ANNUAL REPORT 2017-03-02
ANNUAL REPORT 2016-04-19
ANNUAL REPORT 2015-01-21
ANNUAL REPORT 2014-03-06

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339277089 0420600 2013-08-15 950 CHERRY HILLS DRIVE, SUN CITY CENTER, FL, 33571
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2013-09-16
Emphasis L: FALL
Case Closed 2015-10-02

Related Activity

Type Accident
Activity Nr 838260

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19101052 K
Issuance Date 2013-12-17
Abatement Due Date 2014-02-25
Current Penalty 500.0
Initial Penalty 1600.0
Final Order 2014-01-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1052(k): Hazard communication- The Employer had not developed or implemented a written hazard communication program which included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (Construction Reference: 1926.1152) a) for employees applying and removing Klean-Strip Premium Sprayable Stripper to the sheet metal gazebo roof located at 950 Cherry Hills Drive, Sun City Center (FL), on or about 08/07/2013. As per the safety data sheet (SDS), the stripping product contained 70-85% methylene chloride, a known carcinogen.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19101052 L
Issuance Date 2013-12-17
Abatement Due Date 2014-02-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1052(l): Employee information and training - Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.1152) a) for employees applying and removing Klean-Strip Premium Sprayable Stripper to the sheet metal gazebo roof located at 950 Cherry Hills Drive, Sun City Center (FL), on or about 08/07/2013. As per the safety data sheet (SDS), the stripping product contained 70-85% methylene chloride, a known carcinogen.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19101052 D01
Issuance Date 2013-12-17
Abatement Due Date 2014-02-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1052(d)(1): Exposure monitoring - Where methylene chloride was present in the workplace, the did not determine/characterize each employees' exposure by air sampling: (Construction Reference: 1926.1152) a) for employees applying and removing Klean-Strip Premium Sprayable Stripper to the sheet metal gazebo roof located at 950 Cherry Hills Drive, Sun City Center (FL), on or about 08/07/2013. As per the safety data sheet (SDS), the stripping product contained 70-85% methylene chloride, a known carcinogen.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 A01
Issuance Date 2013-12-17
Abatement Due Date 2014-01-31
Current Penalty 3000.0
Initial Penalty 6300.0
Final Order 2014-01-15
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(1): Scaffold(s) and scaffold(s) component(s) were not capable of supporting, without failure, its own weight and at least four times the maximum intended load applied or transmitted to it: for the ladder jack scaffold system located at 950 Cherry Hills Drive, Sun City Center (FL) used by employees to strip paint from a sheet metal gazebo roof, on or about 08/07/2013. As observed on or about 08/15/2013 the ladder jack scaffold system and components had various deficiencies in the design and setup that affected the capacity of the system: a) the width of the platform was 11.25 inches instead of 12 inches as required by 29 CFR 1926.451(b)(2)(i) b) the working width of the platform was further reduced by installing the brackets on the inside of the ladder such that the platform was nearly under the edge of the roof. c) the span of the ladder jacks supports was 12 feet instead of 8 feet as per 1926 Subpart L App A - Scaffold Specifications. d) the work platform was sandwiched between the ladder jack support clamps instead of fastened and secured.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 B02 I
Issuance Date 2013-12-17
Abatement Due Date 2014-01-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-15
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2)(i): Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold was not at least 12 inches (30 cm) wide: a) at the gazebo located at 950 Cherry Hills Drive, Sun City Center (FL) - for employees stripping and scrapping paint from a sheet metal gazebo roof using a ladder jack scaffold with a platform 11.25 inches wide, on or about 08/07/2013.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2013-12-17
Abatement Due Date 2014-01-31
Current Penalty 750.0
Initial Penalty 2800.0
Final Order 2014-01-15
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; such activities were not performed only by experienced and trained employees selected for such work by the competent person: a) for the ladder jack scaffold sytem used at the gazebo located at 950 Cherry Hills Drive, Sun City Center (FL), on or about 08/07/2013. The owner, who designed and erected the scaffold system: 1) did not assure the width of the platform was at least 12-inches. 2) did not assure the platform was not under the edge of the roof. 3) did not assure the span of the ladder jacks was only 8 feet as per 1926 Subpart L App A - Scaffold Specifications. 4) did not assure the work platform was properly secured.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2013-12-17
Abatement Due Date 2014-01-31
Current Penalty 750.0
Initial Penalty 2800.0
Final Order 2014-01-15
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) for the employees stripping and scrapping paint from the sheet metal gazebo roof using a ladder jack scaffold system at the gazebo located at 950 Cherry Hills Drive, Sun City Center (FL), on or about 8/07/2013. Employees had not received training to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards, on or about 08/15/2013.