Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2018-12-13
|
Emphasis |
N: LEAD, P: LEAD
|
Case Closed |
2019-04-03
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100215 A04 |
Issuance Date |
2019-02-28 |
Abatement Due Date |
2019-03-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-03-26 |
Nr Instances |
1 |
Nr Exposed |
14 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: a) On or about December 13, 2018, in the mechanical shop area, the employer failed to provide a work rest on the Blue-Point BG-333G bench grinder to support off-hand grinding work, exposing the employees to struck-by hazards. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100215 B09 |
Issuance Date |
2019-02-28 |
Abatement Due Date |
2019-03-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-03-26 |
Nr Instances |
1 |
Nr Exposed |
14 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: a) On or about December 13, 2018, in the mechanical shop area, the employer failed to ensure that the employees using the Blue-Point BG-333G bench grinder were protected from injuries by an adjustable tongue guard in case the grinding wheel breaks and the pieces strike hands of the operator. |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19100303 G01 |
Issuance Date |
2019-02-28 |
Abatement Due Date |
2019-04-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-03-26 |
Nr Instances |
1 |
Nr Exposed |
14 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) On or about December 13, 2018, in the mechanical shop area, the employer failed to ensure that the working space in front of the electrical breakers panels were clear of obstructions. The space in front of the electrical breakers panels in the shop area was used to store a plastic bin and boxes. |
|
Citation ID |
01004A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2019-02-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-03-26 |
Nr Instances |
1 |
Nr Exposed |
14 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about December 13, 2018, in the shop area, the employer failed to develop, implement and maintain a written Hazard Communication Program for the protection of the employees using hazardous chemicals, including but not limited to Auto Extra Break and Parts cleaner and CRC white Lithium Grease. |
|
Citation ID |
01004B |
Citaton Type |
Other |
Standard Cited |
19101200 E01 I |
Issuance Date |
2019-02-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-03-26 |
Nr Instances |
1 |
Nr Exposed |
14 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet. a) On or about December 13, 2018, in the shop area, the employer failed to a list of all hazardous chemicals used and stored in the workplace, such as solvents, cleaners and lubricants, including but not limited to NAPA ATF, Auto Extra Break and Parts cleaner and CRC White Lithium Grease. |
|
|