347095465
|
0420600
|
2023-11-09
|
14055 US HWY 19 N., CLEARWATER, FL, 33764
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-11-09
|
Case Closed |
2024-05-09
|
Related Activity
Type |
Complaint |
Activity Nr |
2098776 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2024-02-27 |
Abatement Due Date |
2024-04-12 |
Current Penalty |
4977.6 |
Initial Penalty |
8296.0 |
Final Order |
2024-04-05 |
Nr Instances |
1 |
Nr Exposed |
125 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Effective chip guarding and personal protective equipment was not used when compressed air was used for cleaning purposes and the compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. a. At the 14055 US Hwy 19 N. Clearwater, FL: On or about November 11, 2023, the employer exposed employees to eye hazards, in that, an employee was using a pneumatic gun to blow built-up debris while the stamping machine was running, during which time the compressed air supplied to the pneumatic gun from the air compressor was set to 80 PSI and the air gun was not equipped with a safety tip nozzle nor was effective chip guarding used on the gun therefore exposing the employee to the hazards of the release of the compressed air and flying debris. |
|
|
341040509
|
0420600
|
2015-11-06
|
14055 US HWY 19 NORTH, CLEARWATER, FL, 33764
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-11-06
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2016-01-20
|
Related Activity
Type |
Complaint |
Activity Nr |
1034856 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A05 |
Issuance Date |
2015-12-22 |
Current Penalty |
2970.0 |
Initial Penalty |
4950.0 |
Final Order |
2016-01-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(5): When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the fan's blades were not guarded by a guard which had openings no larger than one-half (1/2) inch. a) Stamping Area Near Press 28 - employees were exposed to an amputation hazard, in that, a floor fan had openings of 1 inch by 2 inch, on or about November 6, 2015. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100219 B01 |
Issuance Date |
2015-12-22 |
Abatement Due Date |
2016-01-20 |
Current Penalty |
2970.0 |
Initial Penalty |
4950.0 |
Final Order |
2016-01-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv): a) Stamping Area - Press 28, bottom of the unguarded flywheel was 6 feet 3 inches above the floor, on or about November 6, 2015. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100219 B02 |
Issuance Date |
2015-12-22 |
Abatement Due Date |
2016-01-20 |
Current Penalty |
1782.0 |
Initial Penalty |
2970.0 |
Final Order |
2016-01-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(b)(2): Crank(s) or connecting rod(s) exposed to contact were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o) or by guardrail(s) as described in CFR 1910.219(o)(5): a) Stamping Area - Press 28, an approximately 2 1/2 to 3 foot long rod that connected the flywheel to a piece of equipment was unguarded, on or about November 6, 2015. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100217 C01 I |
Issuance Date |
2015-12-22 |
Abatement Due Date |
2016-01-20 |
Current Penalty |
8316.0 |
Initial Penalty |
13860.0 |
Final Order |
2016-01-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es): a) Stamping Area, Press 40 - Precision Industries part-revolution 32-ton mechanical power press was missing the plastic side guard and metal chute guard, on or about October 13, 2015. E.S. Investments, LLC dba Sun Microstamping Technologies was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.217(c)(1)(i), which was contained in OSHA inspection number 580879, citation number 1, item number 2a, and was affirmed as a final order on 12/27/12, with respect to a workplace located at 14055 US Hwy 19 N., Clearwater, FL 33764. |
|
Citation ID |
02002A |
Citaton Type |
Repeat |
Standard Cited |
19100219 D01 |
Issuance Date |
2015-12-22 |
Abatement Due Date |
2016-01-20 |
Current Penalty |
5940.0 |
Initial Penalty |
9900.0 |
Final Order |
2016-01-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Stamping Area, Near Press 28 - A floor fan had an inadequately guarded pulley 1 to 2 feet from the floor, on or about November 6, 2015. E.S. Investments, LLC dba Sun Microstamping Technologies was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.219(d)(1), which was contained in OSHA inspection number 580879, citation number 1, item number 3a, and was affirmed as a final order on 12/27/12, with respect to a workplace located at 14055 US Hwy 19 N., Clearwater, FL 33764. |
|
Citation ID |
02002B |
Citaton Type |
Repeat |
Standard Cited |
19100219 E03 I |
Issuance Date |
2015-12-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-01-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a) Stamping Area, Near Press 28 - A floor fan had an inadequately guarded vertical belt 1 to 2 feet from the floor, on or about November 6, 2015. E.S. Investments, LLC dba Sun Microstamping Technologies was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.219(e)(3)(i), which was contained in OSHA inspection number 580879, citation number 1, item number 3b, and was affirmed as a final order on 12/27/12, with respect to a workplace located at 14055 US Hwy 19 N., Clearwater, FL 33764. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2015-12-22 |
Abatement Due Date |
2016-01-20 |
Current Penalty |
594.0 |
Initial Penalty |
990.0 |
Final Order |
2016-01-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours: a) An employee suffered an amputation on October 13, 2015. The employer was aware of the amputation on October 13, 2015. OSHA was notified of the incident by a complaint filed on November 3, 2015. |
|
|
335808796
|
0420600
|
2012-08-15
|
14055 US HWY 19 N., CLEARWATER, FL, 33764
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2012-11-08
|
Emphasis |
L: EISAOF, N: AMPUTATE, L: FORKLIFT, L: EISAX
|
Case Closed |
2013-05-08
|
Related Activity
Type |
Complaint |
Activity Nr |
488790 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100095 C01 |
Issuance Date |
2012-11-20 |
Abatement Due Date |
2012-12-17 |
Current Penalty |
2700.0 |
Initial Penalty |
4500.0 |
Final Order |
2012-12-14 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: a) Stamping Area - An effective program was not maintained and an employee was exposed to noise levels at 88.8 % of the allowable 8-hour weighted average (TWA) sound level (80 dBA), on or about August 15, 2012. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100095 G01 |
Issuance Date |
2012-11-20 |
Abatement Due Date |
2012-12-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-14 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels: a) Stamping Area - An audiogram was not provided for a press operator hired in March 2012 and who was exposed to noise levels at 88.8 % of the allowable 8-hour weighted average (TWA) sound level (80 dBA), on or about November 9, 2012. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100095 K01 |
Issuance Date |
2012-11-20 |
Abatement Due Date |
2012-12-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-14 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(k)(1): The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k): a) Stamping Area - Training was not provided to a press operator, who was exposed to noise levels at 88.8 % of the allowable 8-hour weighted average (TWA) sound level (80 dBA), on or about October 17, 2012. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100217 C01 I |
Issuance Date |
2012-11-20 |
Abatement Due Date |
2012-12-03 |
Current Penalty |
3780.0 |
Initial Penalty |
6300.0 |
Final Order |
2012-12-14 |
Nr Instances |
2 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es) a) Press 46, Stamping Area - Inadequate guarding existed on the front and back of Minster partial revolution power press, model P2-60-32, serial number 19275, 60-ton, on or about August 15, 2012. b) Press 46, Stamping Area - A 12 inch by 13 inch unguared opening existed on the side of Minster partial revolution power press, model P2-60-32, serial number 19275, 60-ton, on or about August 15, 2012. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100217 D09 I |
Issuance Date |
2012-11-20 |
Abatement Due Date |
2012-12-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-14 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(d)(9)(i): The employer did not establish a die setting procedure for mechanical power presses that would ensure compliance with 29 CFR 1910.217(c): a) Press 46, Stamping Area - No procedure was developed for a Minster partial revolution power press, model P2-60-32, serial number 19275, 60-ton, on or about August 15, 2012. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100217 D09 IV |
Issuance Date |
2012-11-20 |
Abatement Due Date |
2012-12-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-14 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(d)(9)(iv): Safety blocks were not used when mechanical power press dies were being adjusted or repaired in the press: a) Press 46, Stamping Area - No blocks were used for a Minster partial revolution power press, model P2-60-32, serial number 19275, 60-ton, on or about August 15, 2012. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2012-11-20 |
Current Penalty |
2700.0 |
Initial Penalty |
4500.0 |
Final Order |
2012-12-14 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Press 46, Stamping Area - Four pulleys, the lowest of which was 57 inches above the floor, were not guarded, on or about August 15, 2012. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100219 E03 I |
Issuance Date |
2012-11-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-14 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a) Press 46, Stamping Area - A vertical belt was not guarded, on or about August 15, 2012. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2012-11-20 |
Abatement Due Date |
2012-11-27 |
Current Penalty |
1620.0 |
Initial Penalty |
2700.0 |
Final Order |
2012-12-14 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Press 46, Stamping Area - A nozzle provided 62 p.s.i., on or about Auguest 15, 2012. |
|
|