Search icon

YOUNG'S MASONRY, INC. - Florida Company Profile

Company Details

Entity Name: YOUNG'S MASONRY, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

YOUNG'S MASONRY, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 07 Jun 1989 (36 years ago)
Last Event: AMENDMENT
Event Date Filed: 05 Aug 2016 (9 years ago)
Document Number: K93530
FEI/EIN Number 592952248

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 235 State Road 207, ST. AUGUSTINE, FL, 32084, US
Mail Address: 3889 WINTERHAWK CT, ST. AUGUSTINE, FL, 32086, US
ZIP code: 32084
County: St. Johns
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
YOUNG ANGELA K President 3889 WINTERHAWK CT, ST. AUGUSTINE, FL, 32086
YOUNG ANGELA K Secretary 3889 WINTERHAWK CT, ST. AUGUSTINE, FL, 32086
YOUNG JEREMY J Vice President 3889 WINTERHAWK CT, ST. AUGUSTINE, FL, 32086
YOUNG MICHAEL C Secretary 3889 WINTERHAWK CT, ST. AUGUSTINE, FL, 32086
YOUNG ANGELA K Agent 3889 WINTERHAWK CT, ST. AUGUSTINE, FL, 32086

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2021-01-11 235 State Road 207, ST. AUGUSTINE, FL 32084 -
AMENDMENT 2016-08-05 - -
REGISTERED AGENT NAME CHANGED 2016-08-05 YOUNG, ANGELA K -
AMENDMENT 2016-07-27 - -

Documents

Name Date
ANNUAL REPORT 2024-01-29
ANNUAL REPORT 2023-01-24
ANNUAL REPORT 2022-01-11
ANNUAL REPORT 2021-01-11
ANNUAL REPORT 2020-01-16
ANNUAL REPORT 2019-02-11
ANNUAL REPORT 2018-02-16
ANNUAL REPORT 2017-01-10
Amendment 2016-08-05
Amendment 2016-07-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341232999 0419700 2016-02-04 333 SOUTH PONCE DE LEON, BLVD., SAINT AUGUSTINE, FL, 32084
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-02-04
Emphasis L: FALL, P: FALL
Case Closed 2016-03-17

Related Activity

Type Inspection
Activity Nr 1123315
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2016-02-16
Current Penalty 2940.0
Initial Penalty 4900.0
Final Order 2016-03-11
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about February 4, 2016, on exterior block wall, an employee filling cells was not protected from a 37 feet fall hazard by the use of a fall protection system. b. On or about February 4, 2016, in the interior stairwell, an employee holding the slack to the concrete hose working on the edge of the stairwell was not protected from a 28 feet fall hazard by the use of a fall protection system.
Citation ID 02001
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2016-02-16
Abatement Due Date 2016-04-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-03-11
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1): A safety and health program was not initiated and maintained to provide compliance with the general safety and health provisions of the standard: a. On or about February 4, 2016, at the worksite, a safety and health program had not been initiated and maintained which addressed the following basic elements: 1. Management Commitment and Leadership a. Policy statement: goals established, issued, and communicated to employees. b. Program Reviewed Annually. c. Participation in safety meetings, inspections; agenda item in meetings. d. Adequate commitment of resources. e. Safety rules and procedures incorporated into site operations. f. Management observations of safety rules. 2. Assignment of Responsibility a. Safety designee on site, knowledgeable, and accountable. b. Supervisors' (including foremen) safety and health responsibilities understood. c. Employees adherence to safety rules. 3. Identification and Control of Hazards a. Periodic site inspection program involving supervisors. b. Preventive controls in place (PPE, Maintenance, Engineering Controls). c. Action taken to address hazards. d. Safety Committee, where appropriate. e. Technical reference materials available. 4. Training and Education a. Supervisors receive basic safety and health training. b. Specialized training taken when needed. c. Existence of an employee training program, which is ongoing and effective. 5. Recordkeeping and Hazard Analysis
335350385 0419700 2012-07-09 600 S. PLANTATION DR., SAINT AUGUSTINE, FL, 32080
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2012-07-09
Emphasis L: FALL, L: EISAX, L: EISAOF, P: FALL
Case Closed 2013-11-22

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01 I
Issuance Date 2012-12-19
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2013-01-15
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. a. On or about July 9, 2012, on the north side of the building, the scaffold platform was not fully planked, exposing employees to a 10 feet 10 inches fall hazard.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2012-12-19
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2013-01-15
Nr Instances 2
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): The supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a. On or about July 9, 2012, on the north side of the building, the scaffold poles, legs, and frames were bearing directly on wood or concrete blocks and not base plates, exposing the employees to a fall hazard of 10 feet 10 inches. b. On or about July 9, 2012, on the north side of the building, the scaffold poles, legs, and frames were bearing directly on wood or concrete blocks and not base plates, exposing the employees to a fall hazard of 6 feet 8 inches.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02 II
Issuance Date 2012-12-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-01-15
Nr Instances 2
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: a. On or about July 9, 2012, on the north side of the building, the scaffold was supported by concrete blocks, exposing employees to a fall hazard of 10 feet 10 inches. b. On or about July 9, 2012, on the east side of the building, the scaffold was supported by concrete blocks, exposing employees to a fall hazard of 6 feet 8 inches.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2012-12-19
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2013-01-15
Nr Instances 2
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6m) above or below the point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface were not used: a. On or about July 9, 2012, on the north side of the building, a safe means of access was not provided to the second level working platfom, exposing employees to a 10 feet 10 inches fall hazard. b. On or about July 9, 2012, on the east side of the building, a safe means of access was not provided to the first level working platform, exposing employees to a 6 feet 8 inches fall hazard.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2012-12-19
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2013-01-15
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about July 9, 2012, on the north side of the building, the scaffold did not have a guardail on all open sides and ends, exposing emplyees to a 10 feet 10 inches fall hazard.
302733308 0419700 1999-08-31 1357 WILDWOOD DR., ST AUGUSTINE, FL, 32086
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 1999-08-31
Emphasis L: FLCARE, S: CONSTRUCTION
Case Closed 2000-01-27

Related Activity

Type Referral
Activity Nr 201351848
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 1999-09-03
Abatement Due Date 1999-09-10
Current Penalty 600.0
Initial Penalty 600.0
Nr Instances 1
Nr Exposed 1
Gravity 02
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260602 C01 VIIIA
Issuance Date 1999-09-03
Abatement Due Date 1999-09-10
Nr Instances 1
Nr Exposed 1
Gravity 02