Search icon

THE GLASS PROFESSIONALS, INC. - Florida Company Profile

Company Details

Entity Name: THE GLASS PROFESSIONALS, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

THE GLASS PROFESSIONALS, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 03 May 1989 (36 years ago)
Document Number: K85569
FEI/EIN Number 650124751

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3570 SE DIXIE HIGHWAY, STUART, FL, 34997, US
Mail Address: 3570 SE DIXIE HIGHWAY, STUART, FL, 34997, US
ZIP code: 34997
County: Martin
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
LAPRADE WILLIAM K Vice President 5332 SW LANDING CREEK DR, PALM CITY, FL, 34990
LAPRADE DAVID A President 17017 NW 294th Street, Okeechobee, FL, 34972
CONLON & ASSOCIATES, LLC Agent -

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G19000067089 GP WINDOW & DOOR DISTRUBUTORS EXPIRED 2019-06-12 2024-12-31 - 3572 SE DIXIE HWY., STUART, FL, 34997
G18000084752 GP DISTRIBUTORS ACTIVE 2018-08-02 2028-12-31 - 3570 SE DIXIE HWY, STUART, FL, 34997

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2024-02-05 Conlon & Associates LLC -
REGISTERED AGENT ADDRESS CHANGED 2024-02-05 850 NW Federal Hwy, Suite 101, STUART, FL 34994 -
CHANGE OF PRINCIPAL ADDRESS 2009-01-14 3570 SE DIXIE HIGHWAY, STUART, FL 34997 -
CHANGE OF MAILING ADDRESS 2009-01-14 3570 SE DIXIE HIGHWAY, STUART, FL 34997 -

Documents

Name Date
ANNUAL REPORT 2025-01-31
ANNUAL REPORT 2024-02-05
ANNUAL REPORT 2023-03-01
ANNUAL REPORT 2022-02-02
ANNUAL REPORT 2021-02-23
ANNUAL REPORT 2020-01-21
ANNUAL REPORT 2019-02-07
ANNUAL REPORT 2018-01-18
ANNUAL REPORT 2017-03-15
ANNUAL REPORT 2016-03-29

USAspending Awards. Financial Assistance

FAIN Awarding Agency Assistance Listings Start Date End Date Description
3685785008 Small Business Administration 59.057 - AMERICA'S RECOVERY CAPITAL LOANS - - ARC GUAR LOANS
Recipient THE GLASS PROFESSIONALS INC.
Recipient Name Raw THE GLASS PROFESSIONALS INC.
Recipient DUNS 611785791
Recipient Address 3570 SE DIXIE HIGHWAY, STUART, MARTIN, FLORIDA, 34997-0000, UNITED STATES
Obligated Amount 0.00
Non-Federal Funding 0.00
Original Subsidy Cost 25130.00
Face Value of Direct Loan 33000.00
Link View Page

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344523071 0418800 2019-12-20 1005 NE DOUBLOON DRIVE, STUART, FL, 34996
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2019-12-23
Case Closed 2020-06-30

Related Activity

Type Inspection
Activity Nr 1452366
Safety Yes
Type Referral
Activity Nr 1528418
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260405 G02 IV
Issuance Date 2020-06-06
Current Penalty 2699.0
Initial Penalty 5398.0
Final Order 2020-06-29
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: On or about December 19, 2019, at an elevator inside a concrete poured residential structure under construction located at 1005 NE Doubloon Drive in Stuart, Florida, employees were exposed to a shock hazard when using an elevator control pendant that did not have the flexible power cord provided with strain relief.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B03
Issuance Date 2020-06-06
Current Penalty 4048.0
Initial Penalty 8096.0
Final Order 2020-06-29
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling: On or about December 19, 2019, adjacent to an elevator inside a concrete poured residential structure under construction located at 1005 NE Doubloon Drive in Stuart, Florida, employees were exposed to a fall hazard of approximately 8-feet, 11-inches when performing glass installation work on a fabricated platform scaffold while the work platform was approximately 19-inches away from the face of the elevator glass.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 B04
Issuance Date 2020-06-06
Current Penalty 4048.0
Initial Penalty 8096.0
Final Order 2020-06-29
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(4): Each end of a platform, not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches (15 cm): On or about December 19, 2019, adjacent to an elevator inside a concrete poured residential structure under construction located at 1005 NE Doubloon Drive in Stuart, Florida, employees were exposed to a fall hazard of approximately 8-feet, 11-inches when performing glass installation work on a fabricated platform scaffold where the work platform did not extend at least 6-inches past the centerline of the support beam.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2020-06-06
Current Penalty 4048.0
Initial Penalty 8096.0
Final Order 2020-06-29
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities were not performed only by experienced and trained employees selected for such work by the competent person: On or about December 19, 2019, adjacent to an elevator inside a concrete poured residential structure under construction located at 1005 NE Doubloon Drive in Stuart, Florida, employees were exposed to fall hazards when performing glass installation work from a fabricated platform scaffold that was no erected by a person competent in scaffold erection.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2020-06-06
Abatement Due Date 2020-06-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-29
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: On or about December 19, 2019, on site of a concrete poured residential structure under construction located at 1005 NE Doubloon Drive in Stuart, Florida, employees were exposed to fall hazards when performing glass installation work from a fabricated platform scaffold prior to being provided with a training program that would enable them to recognize the hazards associated with scaffolds.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2020-06-06
Current Penalty 4723.0
Initial Penalty 9446.0
Final Order 2020-06-29
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about December 19, 2019, adjacent to an elevator inside a concrete poured residential structure under construction located at 1005 NE Doubloon Drive in Stuart, Florida, employees were exposed to a fall hazard of approximately 26-feet, 8-inches when performing glass installation work on a fabricated platform scaffold while not being protected from falling to the lower level.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
4648147209 2020-04-27 0455 PPP 3570 SE DIXIE HWY, STUART, FL, 34997
Loan Status Date 2021-08-05
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 283562
Loan Approval Amount (current) 283562
Undisbursed Amount 0
Franchise Name -
Lender Location ID 17616
Servicing Lender Name Seacoast National Bank
Servicing Lender Address 815 Colorado Ave, STUART, FL, 34994-3053
Rural or Urban Indicator U
Hubzone Y
LMI Y
Business Age Description Existing or more than 2 years old
Project Address STUART, MARTIN, FL, 34997-0019
Project Congressional District FL-21
Number of Employees 42
NAICS code 238150
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 17616
Originating Lender Name Seacoast National Bank
Originating Lender Address STUART, FL
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 287050.2
Forgiveness Paid Date 2021-07-29

Date of last update: 03 Apr 2025

Sources: Florida Department of State