Search icon

MASTERS MASONRY OF ST. AUGUSTINE, INC. - Florida Company Profile

Company Details

Entity Name: MASTERS MASONRY OF ST. AUGUSTINE, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

MASTERS MASONRY OF ST. AUGUSTINE, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 01 May 1989 (36 years ago)
Date of dissolution: 23 Sep 2016 (8 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 23 Sep 2016 (8 years ago)
Document Number: K84256
FEI/EIN Number 592952032

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: % TIMOTHY J. MASTERS, 47 DOLPHIN DRIVE, ST. AUGUSTINE, FL, 32084, UN
Mail Address: % TIMOTHY J. MASTERS, 47 DOLPHIN DRIVE, ST. AUGUSTINE, FL, 32084
ZIP code: 32084
County: St. Johns
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MASTERS TIMOTHY J Director 47 DOLPHIN DRIVE, ST. AUGUSTINE, FL
MASTERS TIMOTHY J President 47 DOLPHIN DRIVE, ST. AUGUSTINE, FL
MASTERS TIMOTHY J Agent 47 DOLPHIN DRIVE, SAINT AUGUSTINE, FL, 32084

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2016-09-23 - -
CHANGE OF PRINCIPAL ADDRESS 2012-04-26 % TIMOTHY J. MASTERS, 47 DOLPHIN DRIVE, ST. AUGUSTINE, FL 32084 UN -
CHANGE OF MAILING ADDRESS 2011-04-29 % TIMOTHY J. MASTERS, 47 DOLPHIN DRIVE, ST. AUGUSTINE, FL 32084 UN -
REGISTERED AGENT NAME CHANGED 2010-04-27 MASTERS, TIMOTHY J -
REGISTERED AGENT ADDRESS CHANGED 2001-04-24 47 DOLPHIN DRIVE, SAINT AUGUSTINE, FL 32084 -

Documents

Name Date
ANNUAL REPORT 2015-04-27
ANNUAL REPORT 2014-04-22
ANNUAL REPORT 2013-04-24
ANNUAL REPORT 2012-04-26
ANNUAL REPORT 2011-04-29
ANNUAL REPORT 2010-04-27
ANNUAL REPORT 2009-04-30
ANNUAL REPORT 2008-08-19
ANNUAL REPORT 2007-03-02
ANNUAL REPORT 2006-07-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
337126189 0419700 2012-10-30 310 6TH STREET, ATLANTIC BEACH, FL, 32233
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-10-31
Emphasis L: EISAOF, P: EISAX, L: EISAX
Case Closed 2014-01-08

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2012-11-19
Current Penalty 1320.0
Initial Penalty 2200.0
Final Order 2012-12-11
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a. On or about October 30, 2012, employees working at ground level in close proximity to a scaffold were not wearing hard hats, exposing themselves to the hazard of being struck by falling bricks and other materials.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2012-11-19
Current Penalty 1848.0
Initial Penalty 3080.0
Final Order 2012-12-11
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a. On or about October 30, 2012, on the west side of the chimney, the scaffold legs did not have screw jacks and base plates, exposing employees to a scaffold collapse hazard.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02 I
Issuance Date 2012-11-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-12-11
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement: a. On or about October 30, 2012, on the west side of the chimney, the scaffold legs was set on concrete blocks, exposing employees to a scaffold collapse hazard.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2012-11-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-12-11
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a. On or about October 30, 2012, on the west side of the chimney, the scaffold did not have enough cross bracing, exposing employees to a scaffold collapse hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2012-11-19
Current Penalty 1848.0
Initial Penalty 3080.0
Final Order 2012-12-11
Nr Instances 4
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about October 30, 2012, on the west side of the chimney, the 4th level of the scaffold did not have guardrails on the end of the platform or on the open sides of the material platform, exposing employees to an 18 feet fall hazard. b. On or about October 30, 2012, on the south side of the chimney, the 4th level of the scaffold had a walkway platform without a guardrail, exposing employees to an 18 feet fall hazard.
311819692 0419700 2009-01-09 LOT 20A SEA COLONY, ST AUGUSTINE, FL, 32080
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2009-01-12
Emphasis S: RESIDENTIAL CONSTR, S: SILICA, S: STRUCK-BY
Case Closed 2009-08-03

Related Activity

Type Referral
Activity Nr 201357654
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2009-03-11
Abatement Due Date 2009-03-16
Current Penalty 650.0
Initial Penalty 1050.0
Nr Instances 1
Nr Exposed 1
Gravity 05
Citation ID 01001B
Citaton Type Serious
Standard Cited 19101200 G08
Issuance Date 2009-03-11
Abatement Due Date 2009-03-16
Nr Instances 1
Nr Exposed 1
Gravity 05
Citation ID 01001C
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2009-03-11
Abatement Due Date 2009-04-06
Nr Instances 1
Nr Exposed 1
Gravity 05
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2009-03-11
Abatement Due Date 2009-03-16
Current Penalty 650.0
Initial Penalty 1050.0
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 05
Citation ID 02001
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2009-03-11
Abatement Due Date 2009-04-06
Nr Instances 1
Nr Exposed 1
Gravity 01