Entity Name: | TENANT CONTRACTORS, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
TENANT CONTRACTORS, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 08 Sep 1988 (37 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 17 Aug 1992 (33 years ago) |
Document Number: | K33200 |
FEI/EIN Number |
592908871
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 5120 SUBEAM RD, JACKSONVILLE, FL, 32257, US |
Mail Address: | P. O. BOX 23010, JACKSONVILLE, FL, 32241 |
ZIP code: | 32257 |
County: | Duval |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
SAMECK, JACOB | President | 5120 SUBEAM RD, JACKSONVILLE, FL, 32257 |
SAMECK, JACOB | Treasurer | 5120 SUBEAM RD, JACKSONVILLE, FL, 32257 |
SAMECK, JACOB | Director | 5120 SUBEAM RD, JACKSONVILLE, FL, 32257 |
SAMECK, JACOB | Agent | 5120 SUNBEAM RD, JACKSONVILLE, FL, 32257 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT NAME CHANGED | 2013-03-18 | SAMECK, JACOB | - |
REGISTERED AGENT ADDRESS CHANGED | 2013-03-18 | 5120 SUNBEAM RD, JACKSONVILLE, FL 32257 | - |
CHANGE OF PRINCIPAL ADDRESS | 2001-01-08 | 5120 SUBEAM RD, JACKSONVILLE, FL 32257 | - |
REINSTATEMENT | 1992-08-17 | - | - |
CHANGE OF MAILING ADDRESS | 1992-08-17 | 5120 SUBEAM RD, JACKSONVILLE, FL 32257 | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 1991-10-11 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-02-03 |
ANNUAL REPORT | 2023-01-18 |
ANNUAL REPORT | 2022-01-31 |
ANNUAL REPORT | 2021-01-12 |
ANNUAL REPORT | 2020-01-16 |
ANNUAL REPORT | 2019-06-17 |
ANNUAL REPORT | 2018-01-30 |
ANNUAL REPORT | 2017-03-31 |
ANNUAL REPORT | 2016-04-11 |
ANNUAL REPORT | 2015-04-17 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340511807 | 0419700 | 2015-04-02 | 2345 FL-16, SAINT AUGUSTINE, FL, 32084 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1051157 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2015-06-22 |
Current Penalty | 1540.0 |
Initial Penalty | 2800.0 |
Final Order | 2015-07-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about April 2, 2015, at a Starbucks brand commercial restaurant construction site, two subcontracted employees working in areas where there was the possibility of falling objects were not protected by a helmet and exposed to struck-by type head injuries. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2015-06-22 |
Current Penalty | 2695.0 |
Initial Penalty | 4900.0 |
Final Order | 2015-07-15 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface having an unprotected side or edge which was six or more feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, fall arrest systems: a. On or about April 2, 2015, at a Starbucks brand commercial restaurant construction site, two subcontracted employees were installing metal type framing materials from the unprotected edge of a rooftop without fall protection systems in place and exposed to a 17-foot fall hazard. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261051 A |
Issuance Date | 2015-06-22 |
Current Penalty | 0.0 |
Initial Penalty | 2400.0 |
Final Order | 2015-07-15 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: a. On or about April 2, 2015, at a Starbucks brand commercial restaurant construction site, the employer did not provide a stairway or ladder from the lower rooftop to the upper rooftop, therefore two subcontracted employees had to climb a 48-inch break in vertical elevation and were exposed to slip, trip, and fall hazards to the lower level below and exposed to a vertical opening between the two roof tops that had a 13-foot fall hazard to the lower level. |
Citation ID | 01004A |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2015-06-22 |
Current Penalty | 0.0 |
Initial Penalty | 2800.0 |
Final Order | 2015-07-15 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. On or about April 2, 2015, at the Starbucks store commercial construction site, two subcontracted employees used a portable ladder with side rails that did not extend at least 3 feet (.9 m) above the upper landing surface of the lower rooftop, exposing the employees to a 13-foot fall hazard. |
Citation ID | 01004B |
Citaton Type | Serious |
Standard Cited | 19261053 B08 |
Issuance Date | 2015-06-22 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-07-15 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder: a. On or about April 2, 2015, at a Starbucks brand commercial restaurant construction site, two subcontracted employees used a portable ladder that was not secured to prevent accidental displacement by workplace activities or traffic, exposing the employees to a 13-foot fall hazard. |
Inspection Type | Complaint |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 1994-04-26 |
Case Closed | 1994-07-07 |
Related Activity
Type | Complaint |
Activity Nr | 77006138 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19260059 H01 |
Issuance Date | 1994-05-16 |
Abatement Due Date | 1994-05-20 |
Nr Instances | 1 |
Gravity | 01 |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 1994-01-26 |
Case Closed | 1994-04-25 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260500 C01 |
Issuance Date | 1994-03-09 |
Abatement Due Date | 1994-03-15 |
Current Penalty | 975.0 |
Initial Penalty | 975.0 |
Nr Instances | 3 |
Nr Exposed | 6 |
Gravity | 10 |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260500 D01 |
Issuance Date | 1994-03-09 |
Abatement Due Date | 1994-03-15 |
Current Penalty | 975.0 |
Initial Penalty | 975.0 |
Nr Instances | 3 |
Nr Exposed | 6 |
Gravity | 10 |
Inspection Type | Unprog Rel |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 1991-10-29 |
Case Closed | 1992-05-05 |
Related Activity
Type | Referral |
Activity Nr | 901208710 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260020 B02 |
Issuance Date | 1991-11-20 |
Abatement Due Date | 1991-11-26 |
Current Penalty | 100.0 |
Initial Penalty | 300.0 |
Nr Instances | 1 |
Nr Exposed | 9 |
Gravity | 02 |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260059 E01 |
Issuance Date | 1991-11-20 |
Abatement Due Date | 1992-01-31 |
Current Penalty | 225.0 |
Initial Penalty | 225.0 |
Nr Instances | 1 |
Nr Exposed | 9 |
Gravity | 01 |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260451 D06 |
Issuance Date | 1991-11-20 |
Abatement Due Date | 1991-11-26 |
Current Penalty | 225.0 |
Initial Penalty | 300.0 |
Nr Instances | 1 |
Nr Exposed | 9 |
Gravity | 02 |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260451 E04 |
Issuance Date | 1991-11-20 |
Abatement Due Date | 1991-11-26 |
Current Penalty | 225.0 |
Initial Penalty | 300.0 |
Nr Instances | 1 |
Nr Exposed | 9 |
Gravity | 02 |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19260451 E05 |
Issuance Date | 1991-11-20 |
Abatement Due Date | 1991-11-26 |
Initial Penalty | 300.0 |
Nr Instances | 1 |
Nr Exposed | 9 |
Gravity | 02 |
Citation ID | 01006 |
Citaton Type | Serious |
Standard Cited | 19260451 E10 |
Issuance Date | 1991-11-20 |
Abatement Due Date | 1991-11-26 |
Current Penalty | 225.0 |
Initial Penalty | 300.0 |
Nr Instances | 1 |
Nr Exposed | 9 |
Gravity | 02 |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100212 A05 |
Issuance Date | 1991-11-20 |
Abatement Due Date | 1991-11-26 |
Nr Instances | 1 |
Nr Exposed | 9 |
Gravity | 01 |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19260020 B01 |
Issuance Date | 1991-11-20 |
Abatement Due Date | 1992-01-31 |
Nr Instances | 1 |
Nr Exposed | 9 |
Gravity | 01 |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4701877107 | 2020-04-13 | 0491 | PPP | 5120 Sunbeam Road N/A, JACKSONVILLE, FL, 32257-6132 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 01 May 2025
Sources: Florida Department of State