Entity Name: | HENDERSON PRESTRESS CONCRETE, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
HENDERSON PRESTRESS CONCRETE, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 25 Jun 1987 (38 years ago) |
Document Number: | J79744 |
FEI/EIN Number |
592829365
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 822 ANCLOTE RD., TARPON SPRINGS, FL, 34689 |
Mail Address: | 822 ANCLOTE RD., TARPON SPRINGS, FL, 34689, US |
ZIP code: | 34689 |
County: | Pinellas |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
HENDERSON DIRK | President | 822 ANCLOTE RD., TARPON SPRINGS, FL, 34684 |
HENDERSON DIRK | Agent | 822 ANCLOTE RD., TARPON SPRINGS, FL, 34689 |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G22000083555 | HENDERSON PRESTRESSED CONCRETE, INC. | ACTIVE | 2022-07-14 | 2027-12-31 | - | 822 ANCLOTE ROAD, TARPON SPRINGS, FL, 34689 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF MAILING ADDRESS | 2013-01-26 | 822 ANCLOTE RD., TARPON SPRINGS, FL 34689 | - |
REGISTERED AGENT NAME CHANGED | 2013-01-26 | HENDERSON, DIRK | - |
CHANGE OF PRINCIPAL ADDRESS | 2009-05-20 | 822 ANCLOTE RD., TARPON SPRINGS, FL 34689 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-01-15 |
ANNUAL REPORT | 2023-01-24 |
ANNUAL REPORT | 2022-01-26 |
ANNUAL REPORT | 2021-01-29 |
ANNUAL REPORT | 2020-01-14 |
ANNUAL REPORT | 2019-01-07 |
ANNUAL REPORT | 2018-01-24 |
ANNUAL REPORT | 2017-01-17 |
ANNUAL REPORT | 2016-03-07 |
ANNUAL REPORT | 2015-01-22 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345181614 | 0420600 | 2021-03-04 | 822 ANCLOTE RD., TARPON SPRINGS, FL, 34689 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1739110 |
Safety | Yes |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Health |
Close Conference | 2021-03-01 |
Emphasis | N: RCS-NEP |
Case Closed | 2021-04-15 |
Related Activity
Type | Referral |
Activity Nr | 1672908 |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19100134 C02 II |
Issuance Date | 2021-03-11 |
Abatement Due Date | 2021-04-06 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-04-07 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(c)(2)(ii):The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) Henderson Prestressed Concrete - A written respiratory protection program was not developed and employees were allowed to voluntarily wear 3M half-face respirators, on or about January 25, 2021. The employees had not been given a respirator medical evaluation. |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2020-09-23 |
Emphasis | L: FORKLIFT |
Case Closed | 2020-12-29 |
Related Activity
Type | Complaint |
Activity Nr | 1661099 |
Safety | Yes |
Health | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100178 L02 II |
Issuance Date | 2020-11-12 |
Abatement Due Date | 2020-12-09 |
Current Penalty | 3856.0 |
Initial Penalty | 3856.0 |
Final Order | 2020-12-14 |
Nr Instances | 1 |
Nr Exposed | 8 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. a. On or about September, 23, 2020, at 822 Anclote Road, Tarpon Springs, FL. 34689, employees were operating forklifts with a frontend attachment-modification/addition, to lift/move concrete piles, during which the employer failed to ensure that the operators of the forklifts had received initial operator/mechanic training and/or had not been trained by an Experienced person; therefore exposing the operator and the employees/pedestrians in the work area/yard to a roll-over/crushed-by, and struck-by hazard. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100178 L06 |
Issuance Date | 2020-11-12 |
Abatement Due Date | 2020-12-09 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2020-12-14 |
Nr Instances | 1 |
Nr Exposed | 8 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l) and/or The certification did not include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation: a. On or about September, 23, 2020, at 822 Anclote Road, Tarpon Springs, FL. 34689, employees were operating forklifts with a with a frontend attachment/modification, to lift/move concrete piles, during which the employer failed to certify and/or the employers certification of the operators training and performance evaluation did not include the name of the operator, the date of the training, the date of the evaluation, and the identity of the experienced person(s) performing the training and evaluation. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100178 A04 |
Issuance Date | 2020-11-12 |
Abatement Due Date | 2020-12-09 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2020-12-14 |
Nr Instances | 1 |
Nr Exposed | 8 |
Related Event Code (REC) | Complaint |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval and Capacity, operation, and maintenance instruction plates, tags or decals of the powered industrial truck were not changed accordingly: a. On or about September, 23, 2020, at 822 Anclote Road, Tarpon Springs, FL. 34689, employees were operating a forklift without the use of an approved lifting attachment, but rather via utilization of Free rigging (direct attachment to or placement of rigging equipment; slings, shackles, rings, spreader bars etc. onto the tines of a powered industrial truck for a below-the-tines lift) to lift/move concrete piles, during which the employer failed to obtain prior written approval from a qualified registered professional engineer or from the forklift manufacturer for the use of the modification/addition, nor were the trucks durable corrosion resistant capacity, operation, and maintenance instruction plates, tags, and decals changed as required; therefore exposing the operator and the employee on the elevating platform and employees in the work area to a load stability/roll-over and subsequent crush-by, fall and struck-by hazard. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5627768503 | 2021-03-01 | 0455 | PPS | 822 Anclote Rd, Tarpon Springs, FL, 34689-6603 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
8204547306 | 2020-05-01 | 0455 | PPP | 822 ANCLOTE RD, TARPON SPRINGS, FL, 34689-6603 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|