Search icon

ECLIPSE CONSTRUCTION COMPANY - Florida Company Profile

Company Details

Entity Name: ECLIPSE CONSTRUCTION COMPANY
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

ECLIPSE CONSTRUCTION COMPANY is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 13 May 1987 (38 years ago)
Document Number: J72761
FEI/EIN Number 592818587

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 668 HOWARD AVE, LAKELAND, FL, 33815, US
Mail Address: P.O. BOX 5805, LAKELAND, FL, 33807, US
ZIP code: 33815
County: Polk
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
PETRO SCOTT M President 668 Howard Ave, LAKELAND, FL, 33815
PETRO KATHLEEN M Vice President 668 HOWARD AVE, LAKELAND, FL, 33815
Trammell Jennifer N Treasurer 668 HOWARD AVE, LAKELAND, FL, 33815
PETRO SCOTT M Agent 668 HOWARD AVE, LAKELAND, FL, 33815

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G17000100528 ECLIPSE HEATING AND AIR CONDITIONING EXPIRED 2017-09-02 2022-12-31 - P O BOX 5805, LAKELAND, FL, 33807

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2023-03-08 PETRO, SCOTT M -
CHANGE OF PRINCIPAL ADDRESS 2018-01-11 668 HOWARD AVE, LAKELAND, FL 33815 -
REGISTERED AGENT ADDRESS CHANGED 2018-01-11 668 HOWARD AVE, LAKELAND, FL 33815 -
CHANGE OF MAILING ADDRESS 1996-03-20 668 HOWARD AVE, LAKELAND, FL 33815 -

Documents

Name Date
AMENDED ANNUAL REPORT 2024-03-27
ANNUAL REPORT 2024-02-13
ANNUAL REPORT 2023-03-08
ANNUAL REPORT 2022-04-13
ANNUAL REPORT 2021-01-12
ANNUAL REPORT 2020-01-20
ANNUAL REPORT 2019-02-12
ANNUAL REPORT 2018-01-11
ANNUAL REPORT 2017-02-14
ANNUAL REPORT 2016-02-12

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341470342 0420600 2016-05-11 6720 S FLORIDA AVE, LAKELAND, FL, 33813
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-05-11
Emphasis N: TRENCH, P: TRENCH
Case Closed 2016-08-19

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260652 B
Issuance Date 2016-07-20
Abatement Due Date 2016-07-27
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2016-08-15
Nr Instances 2
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.652(b): The slopes and configurations of sloping and benching systems were not in accordance with the requirement options of 29 CFR 1926.652(b)(1), (b)(2), (b)(3), or (b)(4): a) On the south west end section of the excavation, employees were exposed to cave-in hazards While working in an excavation with side walls at heights of 6ft. 1in. and 7ft. 1in. respectively and sloped at angles from the horizontal of 54.7 degrees and 47.6 degrees respectively. The soil present was type B. Employees were installing piping at the bottom of the excavation. b) On the south east section of the excavation, employees were exposed to cave-in hazards due to inadequate benching of type B soil. The bank walls of the section were vertical and benched 22 inches back at the top of the bank. The bench height was 1 ft. 3 in. The total height of the excavation was measured to be 6ft. 1 in. resulting in a vertical, straight wall section below the benching of 4 ft. 10 in. This violates the benching requirements of table B-1 in 29 CFR 1910.652 which require the straight wall section below the benching to be no greater than 4 ft.
Citation ID 01002A
Citaton Type Other
Standard Cited 19260651 K01
Issuance Date 2016-07-20
Abatement Due Date 2016-08-08
Current Penalty 1200.0
Initial Penalty 2400.0
Final Order 2016-08-15
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems: a) For the jobsite at 6720 S Florida Ave., Lakeland, FL 33813, as observed on or about 05/11/2016, excavations were not being inspected by a competent person. The employees inspecting the excavation were not knowledgeable of excavation depth and sloping requirements for the type of soil that was present (type B soil), did not know regulations regarding how deep it was was safe to dig in the soil that was present on site, and did not measure the depth of all the excavation areas employees were working in. Employees were exposed to cave-in hazards while working in the excavation.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2016-07-20
Abatement Due Date 2016-08-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-15
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) For the jobsite at 6720 S Florida Ave., Lakeland, FL 33813, as observed on or about 05/11/2016, employees working in excavations were not instructed on excavation safety standards and hazards. Employees did not know the requisite depth before excavation cave-in protection was needed, employees did not know how soil was classified, and employees did not have a general awareness of proper sloping techniques.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
2699298303 2021-01-21 0455 PPS 668 Howard Ave, Lakeland, FL, 33815-3407
Loan Status Date 2021-11-17
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 90890
Loan Approval Amount (current) 90890
Undisbursed Amount 0
Franchise Name -
Lender Location ID 94641
Servicing Lender Name Midflorida CU
Servicing Lender Address 129 S Kentucky Ave, Ste 100, LAKELAND, FL, 33801-5059
Rural or Urban Indicator U
Hubzone N
LMI Y
Business Age Description Existing or more than 2 years old
Project Address Lakeland, POLK, FL, 33815-3407
Project Congressional District FL-15
Number of Employees 8
NAICS code 237110
Borrower Race Unanswered
Borrower Ethnicity Not Hispanic or Latino
Business Type Corporation
Originating Lender ID 94641
Originating Lender Name Midflorida CU
Originating Lender Address LAKELAND, FL
Gender Female Owned
Veteran Non-Veteran
Forgiveness Amount 91559.85
Forgiveness Paid Date 2021-10-25
8499737006 2020-04-08 0455 PPP 668 HOWARD AVE, LAKELAND, FL, 33815-3407
Loan Status Date 2021-01-13
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 90890
Loan Approval Amount (current) 90890
Undisbursed Amount 0
Franchise Name -
Lender Location ID 94641
Servicing Lender Name Midflorida CU
Servicing Lender Address 129 S Kentucky Ave, Ste 100, LAKELAND, FL, 33801-5059
Rural or Urban Indicator U
Hubzone N
LMI Y
Business Age Description Existing or more than 2 years old
Project Address LAKELAND, POLK, FL, 33815-3407
Project Congressional District FL-15
Number of Employees 8
NAICS code 236220
Borrower Race Unanswered
Borrower Ethnicity Not Hispanic or Latino
Business Type Corporation
Originating Lender ID 94641
Originating Lender Name Midflorida CU
Originating Lender Address LAKELAND, FL
Gender Female Owned
Veteran Non-Veteran
Forgiveness Amount 91503.51
Forgiveness Paid Date 2020-12-16

Date of last update: 01 Apr 2025

Sources: Florida Department of State