Search icon

IRONCLAD WELDING, INC. - Florida Company Profile

Company Details

Entity Name: IRONCLAD WELDING, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

IRONCLAD WELDING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 20 Mar 1987 (38 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 02 Dec 1991 (33 years ago)
Document Number: J62753
FEI/EIN Number 650002070

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: % N. SANDY KONIGSBERG, 314 SW 4th Court, DANIA, FL, 33004, US
Mail Address: % N. SANDY KONIGSBERG, 314 SW 4th Court, DANIA, FL, 33004, US
ZIP code: 33004
County: Broward
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
STAMM, WILLIAM J., JR. President 314 SW 4th Court, DANIA, FL
STAMM ELISE Treasurer 314 SW 4th Court, DANIA, FL, 33004
STAMM WILLIAM Agent 744 SW 12TH AVE, FORT LAUDERDALE, FL, 33312

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2019-03-24 % N. SANDY KONIGSBERG, 314 SW 4th Court, DANIA, FL 33004 -
CHANGE OF MAILING ADDRESS 2019-03-24 % N. SANDY KONIGSBERG, 314 SW 4th Court, DANIA, FL 33004 -
REGISTERED AGENT ADDRESS CHANGED 2000-05-03 744 SW 12TH AVE, FORT LAUDERDALE, FL 33312 -
REGISTERED AGENT NAME CHANGED 1994-04-15 STAMM, WILLIAM -
REINSTATEMENT 1991-12-02 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 1990-11-09 - -

Documents

Name Date
ANNUAL REPORT 2024-01-29
ANNUAL REPORT 2023-02-11
ANNUAL REPORT 2022-04-06
ANNUAL REPORT 2021-02-02
ANNUAL REPORT 2020-03-23
ANNUAL REPORT 2019-03-24
ANNUAL REPORT 2018-01-23
ANNUAL REPORT 2017-03-21
ANNUAL REPORT 2016-01-29
ANNUAL REPORT 2015-01-12

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339410862 0418800 2013-09-12 3301 WEST OAKLAND PARK BLVD, LAUDERDALE LAKES, FL, 33311
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-09-12
Emphasis L: FALL, P: FALL
Case Closed 2015-07-28

Related Activity

Type Inspection
Activity Nr 941001
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2013-11-07
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2013-11-22
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a. On or about September 12, 2013, at the above addressed job site, an employee was allowed to operate a JLG scissor lift without being properly trained.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260701 B
Issuance Date 2013-11-07
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2013-11-22
Nr Instances 1
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: a. On or about September 12, 2013, at the above addressed job site, employees were exposed to impalement hazards while walking near unprotected reinforced steel.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260760 A01
Issuance Date 2013-11-07
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2013-11-22
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems: a. On or about September 12, 2013, at the above addressed job site, employees were allowed to perform initial installment of metal decking on a steel structure without having proper fall protection.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260761 B
Issuance Date 2013-11-07
Abatement Due Date 2013-11-20
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2013-11-22
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.761(b): Fall hazard training. The employer shall train each employee exposed to a fall hazard in accordance with the requirements of this section. The employer shall institute a training program and ensure employee participation in the program: a. On or about September 12, 2013, at the above addressed job site, employees were allowed to perform initial installment of metal decking on a steel structure without being trained on fall hazards.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2013-11-07
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2013-11-22
Nr Instances 5
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. On or about September 12, 2013, at the above addressed job site, employees were allowed to use an extension ladder that did not extend at least 3 feet past the landing surface.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19261053 B15
Issuance Date 2013-11-07
Abatement Due Date 2013-11-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-11-22
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use: a. On or about September 12, 2013, at the above addressed job site, employees were allowed to use an extension ladder that was not inspected prior to use by a competent person.
Citation ID 01005C
Citaton Type Serious
Standard Cited 19261053 B16
Issuance Date 2013-11-07
Abatement Due Date 2013-11-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-11-22
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a. On or about September 12, 2013, at the above addressed job site, employees were allowed to use an extension ladder that had bent cleats and or footpads.
Citation ID 01005D
Citaton Type Serious
Standard Cited 19261060 A01 II
Issuance Date 2013-11-07
Abatement Due Date 2013-11-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-11-22
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a)(1)(ii): The employer did not ensure that each employee using ladders and stairways had been trained by a competent person in the correct procedures for erecting, maintaining, and disassembling the fall protection systems to be used: a. On or about September 12, 2013, at the above addressed job site, employees were not trained on how to inspect, erect, secure, and or properly use an extension ladder prior to its use.