346503287
|
0419700
|
2023-02-14
|
821 VIRGINIA STREET, JACKSONVILLE, FL, 32208
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2023-02-22
|
Emphasis |
L: HINOISE
|
Case Closed |
2023-03-13
|
Related Activity
Type |
Referral |
Activity Nr |
1998608 |
Health |
Yes |
|
|
346450687
|
0419700
|
2023-01-20
|
821 VIRGINIA STREET, JACKSONVILLE, FL, 32208
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-01-20
|
Emphasis |
L: FOODPRO, L: FORKLIFT
|
Case Closed |
2023-06-02
|
Related Activity
Type |
Complaint |
Activity Nr |
1987333 |
Safety |
Yes |
|
Violation Items
Citation ID |
11001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2023-03-20 |
Current Penalty |
3400.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-04-12 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On the box line, specifically the secondary bagger machine: On or about February 25, 2023, and at times prior, the employer exposed employees to amputation hazards, in that the safety interlock switch was missing on the right-hand door. |
|
|
345654354
|
0419700
|
2021-11-23
|
821 VIRGINIA STREET, JACKSONVILLE, FL, 32208
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-12-16
|
Emphasis |
L: FOODPRO, N: AMPUTATE
|
Case Closed |
2022-06-26
|
Related Activity
Type |
Referral |
Activity Nr |
1835922 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I A |
Issuance Date |
2022-05-17 |
Abatement Due Date |
2022-07-06 |
Current Penalty |
4821.7 |
Initial Penalty |
5706.0 |
Final Order |
2022-06-10 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i)(A):Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: a. Production area: On or about November 29, 2021, the employer had not trained the sanitation supervisor and sanitation crew employees that performed cleaning and sanitation of the process equipment as authorized users, on the recognition of applicable hazardous energy sources, exposing employees to amputation hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2022-05-17 |
Abatement Due Date |
2022-07-06 |
Current Penalty |
0.0 |
Initial Penalty |
7133.0 |
Final Order |
2022-06-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(4)(i):Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees: a. Production mixing area at the MTC ribbon mixer blender : On or about November 29, 2021, the employer exposed an employee to amputation hazards, in that the employee had not affixed lockout tagout devices while performing cleaning and sanitation of the machine. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2022-05-17 |
Abatement Due Date |
2022-07-06 |
Current Penalty |
4821.7 |
Initial Penalty |
5706.0 |
Final Order |
2022-06-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c):Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a. Chemical storage area: On or about November 29, 2021, the employer exposed employees to chemical hazards, in that the Speakman eye wash and shower was obstructed and had not been maintained. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100147 C06 II |
Issuance Date |
2022-05-17 |
Abatement Due Date |
2022-07-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-06-10 |
Nr Instances |
1 |
Nr Exposed |
14 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(ii):The employer did not certify that periodic inspections of the energy control procedures had been performed: a. At the establishment: On or about November 23, 2021, the employer had not conducted a periodic inspection of the energy control procedures at least annually to ensure the procedures were adequate and being followed by the authorized employees. |
|
|
343036398
|
0419700
|
2018-03-23
|
821 VIRGINIA STREET, JACKSONVILLE, FL, 32208
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-04-05
|
Emphasis |
N: CHEMNEP
|
Case Closed |
2018-05-09
|
Related Activity
Type |
Referral |
Activity Nr |
1320981 |
Safety |
Yes |
|
|
340927342
|
0419700
|
2015-09-15
|
821 VIRGINIA STREET, JACKSONVILLE, FL, 32208
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2015-10-27
|
Emphasis |
L: HINOISE, N: CHROME6
|
Case Closed |
2016-01-06
|
Related Activity
Type |
Inspection |
Activity Nr |
1092036 |
Safety |
Yes |
|
Type |
Complaint |
Activity Nr |
1018417 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100095 I02 I |
Issuance Date |
2015-11-27 |
Abatement Due Date |
2015-12-23 |
Current Penalty |
6300.0 |
Initial Penalty |
6300.0 |
Final Order |
2015-12-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(i)(2)(i): The employer did not ensure that hearing protectors are worn by an employee who is required by 29 CFR 1910.95(b)(1) to wear personal protective equipment: a. A carton former operator, working on the Box Line nearest the weigh and bagger machine, was exposed to a noise dose of 161.1%, or an equivalent dBA of 93.2 dBA, which was capable of causing permanent hearing loss. The sampling was performed for 475 minutes during one shift on September 17, 2015. The employer did not require the use of hearing protection. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100095 I03 |
Issuance Date |
2015-11-27 |
Abatement Due Date |
2015-12-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-12-29 |
Nr Instances |
1 |
Nr Exposed |
28 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(i)(3): Employees were not given the opportunity to select their hearing protectors from a variety of suitable hearing protectors provided by the employer: a. On or about September 15, 2015, employees working in the Box Line and New Room were included in the hearing conservation program but were only offered Howard Leight Laser Trak ear plugs. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101026 D01 |
Issuance Date |
2015-11-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-12-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): a. On or about September 15, 2015, the employer did not perform initial exposure monitoring for chromium (VI) on an employee who welded materials made of stainless steel. |
|
|
340920362
|
0419700
|
2015-09-15
|
821 VIRGINIA STREET, JACKSONVILLE, FL, 32208
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-10-19
|
Emphasis |
L: FOODPRO, L: FORKLIFT, N: PSMPQV, N: AMPUTATE, L: FALL
|
Case Closed |
2015-12-28
|
Related Activity
Type |
Complaint |
Activity Nr |
1018417 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1092734 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100146 C02 |
Issuance Date |
2015-11-10 |
Abatement Due Date |
2015-11-23 |
Current Penalty |
2160.0 |
Initial Penalty |
3600.0 |
Final Order |
2015-12-16 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: a. On or about September 16, 2015, at the west side of the production room, employees were not warned of the danger posed by the permit-required confined space within the Frigoscandia spiral freezer by posting danger signs or by any other equally effective means . b. On or about September 16, 2015, in the hand packing room, employees were not warned of the danger posed by the permit-required confined space within the mini-spiral freezer by posting danger signs or by any other equally effective means. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100146 D03 |
Issuance Date |
2015-11-10 |
Abatement Due Date |
2015-11-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-12-16 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(d)(3): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations: a. On or about September 16, 2015, in the production room, procedures were not developed or implemented to provide safe entry for employees performing maintenance, cleaning, and sanitation of the Frigoscandia spiral freezer. b. On or about September 16, 2015, in the hand packing room, procedures were not developed or implemented to provide safe entry for employees performing maintenance, cleaning, and sanitation of the mini-spiral freezer. |
|
|
313881278
|
0419700
|
2011-01-25
|
821 VIRGINIA STREET, JACKSONVILLE, FL, 32208
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2011-02-22
|
Emphasis |
N: PSMPQV
|
Case Closed |
2011-08-11
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100119 E05 |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-08-01 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Nr Instances |
2 |
Nr Exposed |
87 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100119 O01 |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-08-01 |
Current Penalty |
2000.0 |
Initial Penalty |
3500.0 |
Nr Instances |
2 |
Nr Exposed |
87 |
Gravity |
05 |
|
|
313880031
|
0419700
|
2010-11-17
|
821 VIRGINIA STREET, JACKSONVILLE, FL, 32208
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2011-03-14
|
Emphasis |
S: NOISE, N: FLAVRING
|
Case Closed |
2011-06-09
|
Related Activity
Type |
Referral |
Activity Nr |
201359155 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100095 C01 |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-05-18 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Nr Instances |
3 |
Nr Exposed |
9 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19101030 C01 I |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-05-18 |
Current Penalty |
2000.0 |
Initial Penalty |
3500.0 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
05 |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-05-18 |
Current Penalty |
400.0 |
Initial Penalty |
700.0 |
Nr Instances |
1 |
Nr Exposed |
87 |
Gravity |
03 |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19101200 H03 II |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-05-18 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
01 |
|
|
313879975
|
0419700
|
2010-11-16
|
821 VIRGINIA STREET, JACKSONVILLE, FL, 32208
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2010-12-01
|
Emphasis |
L: FOODPRO, N: SSTARG10
|
Case Closed |
2011-06-06
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-04-06 |
Current Penalty |
1150.0 |
Initial Penalty |
2100.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100132 D01 |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-04-06 |
Current Penalty |
1150.0 |
Initial Penalty |
2100.0 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-04-13 |
Current Penalty |
1150.0 |
Initial Penalty |
2100.0 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
01 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-05-18 |
Current Penalty |
2000.0 |
Initial Penalty |
3500.0 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
05 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-05-18 |
Current Penalty |
2000.0 |
Initial Penalty |
3500.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
05 |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 IA |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-05-18 |
Current Penalty |
2000.0 |
Initial Penalty |
3500.0 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
05 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040029 B03 |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-04-13 |
Current Penalty |
400.0 |
Initial Penalty |
700.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
00 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19040032 B03 |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-04-13 |
Current Penalty |
400.0 |
Initial Penalty |
700.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
00 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19040032 B03 |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-04-13 |
Current Penalty |
400.0 |
Initial Penalty |
700.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
00 |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19040032 B03 |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-04-13 |
Current Penalty |
400.0 |
Initial Penalty |
700.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
00 |
|
Citation ID |
02005 |
Citaton Type |
Other |
Standard Cited |
19100147 C05 IID |
Issuance Date |
2011-04-01 |
Abatement Due Date |
2011-04-06 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
01 |
|
|
306751462
|
0419700
|
2004-06-23
|
821 VIRGINIA STREET, JACKSONVILLE, FL, 32208
|
|
Inspection Type |
Prog Other
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2004-06-23
|
Case Closed |
2004-07-19
|
|