Entity Name: | FEASTERCO CONSTRUCTION, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
FEASTERCO CONSTRUCTION, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 21 Feb 1986 (39 years ago) |
Last Event: | AMENDMENT |
Event Date Filed: | 06 Feb 2020 (5 years ago) |
Document Number: | J00537 |
FEI/EIN Number |
592637762
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 1000 SW 33RD AVENUE, OCALA, FL, 34474, US |
Mail Address: | 1000 SW 33RD AVENUE, OCALA, FL, 34474, US |
ZIP code: | 34474 |
County: | Marion |
Place of Formation: | FLORIDA |
Type | Company Name | Company Number | State |
---|---|---|---|
Headquarter of | FEASTERCO CONSTRUCTION, INC., MISSISSIPPI | 590963 | MISSISSIPPI |
Headquarter of | FEASTERCO CONSTRUCTION, INC., ALABAMA | 000-941-917 | ALABAMA |
Plan Name | Plan Year | EIN/PN | Received | Sponsor | Total number of participants | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FEASTERCO CONSTRUCTION, INC. 401K PROFIT SHARING PLAN | 2011 | 592637762 | 2012-06-18 | FEASTERCO CONSTRUCTION, INC. | 9 | |||||||||||||||||||||||||||||||||||||||||
|
Administrator’s EIN | 592637762 |
Plan administrator’s name | FEASTERCO CONSTRUCTION, INC. |
Plan administrator’s address | 1000 SW 33RD AVENUE, OCALA, FL, 344742859 |
Administrator’s telephone number | 3523511976 |
Signature of
Role | Plan administrator |
Date | 2012-06-18 |
Name of individual signing | CARMEN M. VARDIS |
Valid signature | Filed with authorized/valid electronic signature |
File | View Page |
Three-digit plan number (PN) | 001 |
Effective date of plan | 1999-07-01 |
Business code | 236200 |
Sponsor’s telephone number | 3523511976 |
Plan sponsor’s address | 1000 SW 33RD AVENUE, OCALA, FL, 344742859 |
Plan administrator’s name and address
Administrator’s EIN | 592637762 |
Plan administrator’s name | FEASTERCO CONSTRUCTION, INC. |
Plan administrator’s address | 1000 SW 33RD AVENUE, OCALA, FL, 344742859 |
Administrator’s telephone number | 3523511976 |
Signature of
Role | Plan administrator |
Date | 2011-05-17 |
Name of individual signing | CARMEN M. VARDIS |
Valid signature | Filed with authorized/valid electronic signature |
File | View Page |
Three-digit plan number (PN) | 001 |
Effective date of plan | 1999-07-01 |
Business code | 236200 |
Sponsor’s telephone number | 3523511976 |
Plan sponsor’s address | 1000 SW 33RD AVENUE, OCALA, FL, 344742859 |
Plan administrator’s name and address
Administrator’s EIN | 592637762 |
Plan administrator’s name | FEASTERCO CONSTRUCTION, INC. |
Plan administrator’s address | 1000 SW 33RD AVENUE, OCALA, FL, 344742859 |
Administrator’s telephone number | 3523511976 |
Signature of
Role | Plan administrator |
Date | 2010-05-05 |
Name of individual signing | TERRY HUDGENS |
Valid signature | Filed with authorized/valid electronic signature |
Role | Employer/plan sponsor |
Date | 2010-05-05 |
Name of individual signing | TERRY HUDGENS |
Valid signature | Filed with authorized/valid electronic signature |
Name | Role | Address |
---|---|---|
FEASTER Donna L | Exec | 1000 SW 33RD AVENUE, OCALA, FL, 34474 |
FEASTER MADISON T | Secretary | 1000 SW 33RD AVENUE, OCALA, FL, 34474 |
FEASTER MADISON T | Treasurer | 1000 SW 33RD AVENUE, OCALA, FL, 34474 |
FEASTER THEODORE W | Vice President | 1000 SW 33RD AVENUE, OCALA, FL, 34474 |
FEASTER T W | Agent | 1000 SW 33RD AVENUE, OCALA, FL, 34474 |
FEASTER, T.W. | President | 1000 SW 33RD AVENUE, OCALA, FL, 34474 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
AMENDMENT | 2020-02-06 | - | - |
REGISTERED AGENT ADDRESS CHANGED | 2019-02-08 | 1000 SW 33RD AVENUE, SUITE 100, OCALA, FL 34474 | - |
CHANGE OF PRINCIPAL ADDRESS | 2019-02-08 | 1000 SW 33RD AVENUE, SUITE 100, OCALA, FL 34474 | - |
CHANGE OF MAILING ADDRESS | 2019-02-08 | 1000 SW 33RD AVENUE, SUITE 100, OCALA, FL 34474 | - |
AMENDMENT | 2015-02-27 | - | - |
AMENDMENT | 2012-12-17 | - | - |
NAME CHANGE AMENDMENT | 2006-10-09 | FEASTERCO CONSTRUCTION, INC. | - |
REGISTERED AGENT NAME CHANGED | 1998-02-05 | FEASTER, T W | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-02-01 |
ANNUAL REPORT | 2023-02-01 |
ANNUAL REPORT | 2022-01-20 |
ANNUAL REPORT | 2021-01-11 |
Amendment | 2020-02-06 |
ANNUAL REPORT | 2020-01-15 |
ANNUAL REPORT | 2019-02-08 |
ANNUAL REPORT | 2018-01-09 |
ANNUAL REPORT | 2017-01-10 |
ANNUAL REPORT | 2016-03-02 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346516677 | 0419700 | 2023-02-21 | 4142 PERIMETER INDUSTRIAL PARKWAY, JACKSONVILLE, FL, 32219 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1999417 |
Safety | Yes |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2015-06-12 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2015-11-25 |
Related Activity
Type | Complaint |
Activity Nr | 990432 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2015-08-31 |
Current Penalty | 2500.0 |
Initial Penalty | 1785.0 |
Final Order | 2015-09-16 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Scaffold rungs were used as a means of access: a. On or about June 10, 2015, 4th floor, employees of LL & J Concrete, Inc. were climbing the scaffold rungs to gain access and exit from a one-buck high scaffold system because there was no ladder. Employees were exposed to a 4 foot fall hazard. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260451 G01 VI |
Issuance Date | 2015-08-31 |
Current Penalty | 0.0 |
Initial Penalty | 4900.0 |
Final Order | 2015-09-16 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(vi): Each employee performing overhand bricklaying operations from a supported scaffold was not protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity): a. On or about June 10, 2015, 4th floor, employees of LL & J Concrete, Inc. were performing overhand bricklaying operations. The ends of the scaffolds did not have guardrails and employees were not protected from falling 35 feet by the use of a guardrail system, safety net system, personal fall arrest system or any other type of fall protection method. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2015-08-31 |
Current Penalty | 4900.0 |
Initial Penalty | 4900.0 |
Final Order | 2015-09-16 |
Nr Instances | 1 |
Nr Exposed | 10 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about June 10, 2015, 4th floor, employees of LL & J Concrete, Inc. were erecting scaffold, installing guardrail systems, moving cinder blocks and the mud barrel outside the warning line near the edge of the building were not protected from falling 35 feet by the use of a guardrail system, safety net system, personal fall arrest system or any other type of fall protection. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260502 I03 |
Issuance Date | 2015-08-31 |
Current Penalty | 0.0 |
Initial Penalty | 4900.0 |
Final Order | 2015-09-16 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees: a. On or about June 10, 2015, 2nd through 4th floors, covers over the duct work and linen chutes were not secured to prevent accidental displacement. Employees of LL & J Concrete and temporary laborers working for Feasterco Construction, Inc., working near these areas were exposed to an 8 feet 8-inch fall hazard. |
Citation ID | 01002C |
Citaton Type | Serious |
Standard Cited | 19260502 I04 |
Issuance Date | 2015-08-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-09-16 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: a. On or about June 10, 2015, 2nd through 4th floors, the covers did not have the word "hole" and employees of LL& J Concrete and temporary laborers of Feasterco Construction working around these areas were exposed to an 8 feet 8-inch fall hazard. |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2006-12-14 |
Emphasis | S: COMMERCIAL CONSTR, L: FALL, S: FALL FROM HEIGHT |
Case Closed | 2007-01-08 |
Related Activity
Type | Complaint |
Activity Nr | 206141624 |
Safety | Yes |
Type | Complaint |
Activity Nr | 206162711 |
Safety | Yes |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2005-10-21 |
Emphasis | L: FALL |
Case Closed | 2005-11-15 |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6839138302 | 2021-01-27 | 0491 | PPS | 1000 SW 33rd Ave, Ocala, FL, 34474-2804 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2815567205 | 2020-04-16 | 0491 | PPP | 1000 SW 33rd Ave,, Ocala, FL, 34474-2804 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 02 Apr 2025
Sources: Florida Department of State