345690549
|
0419730
|
2021-12-14
|
1500 W. CHURCH STREET, ORLANDO, FL, 32805
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-12-14
|
Case Closed |
2022-04-12
|
Related Activity
Type |
Complaint |
Activity Nr |
1840840 |
Safety |
Yes |
Health |
Yes |
|
|
340745090
|
0420600
|
2015-06-30
|
1500 W. CHURCH STREET, ORLANDO, FL, 32805
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-06-30
|
Case Closed |
2015-12-30
|
Related Activity
Type |
Referral |
Activity Nr |
995514 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1074673 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2015-12-02 |
Current Penalty |
2520.0 |
Initial Penalty |
4200.0 |
Final Order |
2015-12-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. On or about 06/24/2015, the pretzel line - employees were permitted to clean the pretzel machine while the electric cord was connected to the power source exposing the employee to an amputation hazard. One employee was injured while the machine was running during the cleaning process. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I |
Issuance Date |
2015-12-02 |
Abatement Due Date |
2015-12-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-12-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a. On or about 06/24/2015, the pretzel line - employees required to clean the pretzel line machine were not provided with authorize employee training. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2015-12-02 |
Abatement Due Date |
2015-12-14 |
Current Penalty |
2100.0 |
Initial Penalty |
3500.0 |
Final Order |
2015-12-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. On or about 06/24/2015, the pretzel line - employees are permitted to clean the pretzel machine while energized, exposing them to an amputation hazard, in that, the safety guards were not installed. Employees are required to remove the die press which is near the bandcutter section. |
|
|
338953532
|
0420600
|
2013-03-13
|
1500 W. CHUCH ST., ORLANDO, FL, 32805
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-03-13
|
Emphasis |
L: EISAOF, L: EISAX, L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2013-05-08
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100036 D01 |
Issuance Date |
2013-04-25 |
Abatement Due Date |
2013-05-07 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-05-08 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) On or about 03-13-2013 in the shipping and receiving area, exit doors were secured with locks, exposing employees to a fire hazard. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100037 A03 |
Issuance Date |
2013-04-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-05-08 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) On or about 03-13-2013 at the shipping/receiving dock area, a exit door was not maintained free and unobstructed from wooden pallets exposing employees to a fire hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 III |
Issuance Date |
2013-04-25 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-05-08 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least: a) On or about 03-13-2013 in the maintenance department, oxygen and acetylene cylinders were stored together. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100303 G01 |
Issuance Date |
2013-04-25 |
Current Penalty |
1260.0 |
Initial Penalty |
2100.0 |
Final Order |
2013-05-08 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) On or about 03-13-2013 in building 1500, electrical panels in the shipping/receiving area and the production area were blocked by pallets with boxes or carts with bread, making the panels inaccessible. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100176 B |
Issuance Date |
2013-04-25 |
Abatement Due Date |
2013-05-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-05-08 |
Nr Instances |
1 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a) On or about 03-13-2013 in the warehouse, metal racks used to store baking products were not secured to the floor exposing employees to a struck-by hazard. |
|
|
310421433
|
0420600
|
2006-08-28
|
1500 W. CHURCH STREET, ORLANDO, FL, 32805
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2006-08-29
|
Case Closed |
2006-11-27
|
Related Activity
Type |
Referral |
Activity Nr |
202666947 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2006-11-02 |
Abatement Due Date |
2006-11-20 |
Current Penalty |
2625.0 |
Initial Penalty |
3500.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100219 F03 |
Issuance Date |
2006-11-02 |
Abatement Due Date |
2006-11-07 |
Current Penalty |
2625.0 |
Initial Penalty |
3500.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
|
303155790
|
0420600
|
2000-01-25
|
1500 W. CHURCH STREET, ORLANDO, FL, 32805
|
|
Inspection Type |
Planned
|
Scope |
Records
|
Safety/Health |
Safety
|
Close Conference |
2000-01-25
|
Emphasis |
S: FOOD PROCESSING, N: SSINTARG
|
Case Closed |
2000-02-01
|
|
106497852
|
0420600
|
1992-04-07
|
1500 W. CHURCH STREET, ORLANDO, FL, 32805
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1992-04-08
|
Case Closed |
1992-06-12
|
Related Activity
Type |
Referral |
Activity Nr |
901166306 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
1992-05-20 |
Abatement Due Date |
1992-06-22 |
Current Penalty |
750.0 |
Initial Penalty |
750.0 |
Nr Instances |
10 |
Nr Exposed |
12 |
Related Event Code (REC) |
Referral |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
1992-05-20 |
Abatement Due Date |
1992-06-02 |
Current Penalty |
750.0 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100263 C03 |
Issuance Date |
1992-05-20 |
Abatement Due Date |
1992-05-25 |
Current Penalty |
2500.0 |
Initial Penalty |
2500.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100303 F |
Issuance Date |
1992-05-20 |
Abatement Due Date |
1992-06-02 |
Current Penalty |
750.0 |
Initial Penalty |
750.0 |
Nr Instances |
10 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 |
Issuance Date |
1992-05-20 |
Abatement Due Date |
1992-05-25 |
Current Penalty |
750.0 |
Initial Penalty |
750.0 |
Nr Instances |
7 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
1992-05-20 |
Abatement Due Date |
1992-06-22 |
Current Penalty |
750.0 |
Initial Penalty |
750.0 |
Nr Instances |
6 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19101200 G01 |
Issuance Date |
1992-05-20 |
Abatement Due Date |
1992-06-22 |
Current Penalty |
750.0 |
Initial Penalty |
750.0 |
Nr Instances |
6 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19101200 H |
Issuance Date |
1992-05-20 |
Abatement Due Date |
1992-06-22 |
Current Penalty |
750.0 |
Initial Penalty |
750.0 |
Nr Instances |
6 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040002 A |
Issuance Date |
1992-05-20 |
Abatement Due Date |
1992-06-06 |
Nr Instances |
5 |
Nr Exposed |
48 |
Gravity |
00 |
|
|