346620800
|
0419700
|
2023-04-07
|
2550 GILMORE STREET CENTRAL RIVERSIDE ELEMENTARY SCHOOL, JACKSONVILLE, FL, 32205
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-04-07
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2023-05-09
|
Related Activity
Type |
Inspection |
Activity Nr |
1662082 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2023-04-18 |
Current Penalty |
1366.2 |
Initial Penalty |
2277.0 |
Final Order |
2023-05-12 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: a. On the roof of a temporary commercial worksite, located at 2550 Gilmore Street (Central Riverside Elementary School) Jacksonville, FL 32205: On or about April 7, 2023, the employer Thomas May Construction Company failed to ensure that its sub-contractor D. R. Roof, Inc. protected its employees from eye injury hazards caused by airborne debris and flying objects, in that eye protection was not utilized by the employee, while using pneumatic nail guns to install roofing shingles. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2023-04-18 |
Current Penalty |
3750.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-05-12 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels were not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a. On a 6:12 pitched roof of a commercial worksite, located at 2550 Gilmore Street, (Central Riverside Elementary School) Jacksonville, FL 32205: On or about April 7, 2023, the employer Thomas May Construction Company failed to ensure that its sub-contractor D.R. Roof, Inc. protected its employees from fall hazards ranging from 10 feet to 30 feet, in that fall protection was not utilized by employees while installing roofing shingles. |
|
|
341945574
|
0419700
|
2016-11-30
|
76500 CURIOSITY AVENUE, YULEE, FL, 32097
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-11-30
|
Emphasis |
L: FALL, L: FORKLIFT, N: CTARGET, P: CTARGET
|
Case Closed |
2017-03-15
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 I |
Issuance Date |
2017-02-15 |
Current Penalty |
5323.8 |
Initial Penalty |
8873.0 |
Final Order |
2017-03-06 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary: a. On or about November 30, 2016, north side exterior of building #2, second and third level of the scaffold, the platform units were not fully planked leaving a space of more than 1 inch between adjacent units, exposing employees installing concrete form work to an 13-foot 5-inch and 19-foot 7-inch fall hazards. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2017-02-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-03-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a. On or about November 30, 2016, employee working on the northeast scaffold used the end frames to access the 2nd and 3rd platform levels, being exposed to fall hazards from 10-foot to 19-foot 7-inch. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2017-02-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-03-06 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a. On or about November 30, 2016, employees installing concrete form work on the north side exterior of building 2 from the 2nd and 3rd levels of the scaffolds without a complete fall protection system, being exposed to 13-foot 5-inch and 19-foot 7-inch fall hazards. |
|
|
308428739
|
0419700
|
2005-02-09
|
6345 CR 218 WEST, JACKSONVILLE, FL, 32224
|
|
Inspection Type |
Unprog Rel
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2005-02-09
|
Emphasis |
L: FALL
|
Case Closed |
2005-03-15
|
Related Activity
Type |
Referral |
Activity Nr |
201355252 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260701 B |
Issuance Date |
2005-03-03 |
Abatement Due Date |
2005-03-08 |
Current Penalty |
675.0 |
Initial Penalty |
1125.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
03 |
|
|
308428440
|
0419700
|
2005-02-02
|
2625 SPENCER PLANTATION BLVD., ORANGE PARK, FL, 32073
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2005-02-02
|
Emphasis |
L: FALL
|
Case Closed |
2005-02-10
|
|
306749490
|
0419700
|
2004-03-03
|
11600 NW 39TH AVENUE, GAINESVILLE, FL, 32605
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2004-03-04
|
Emphasis |
L: FALL
|
Case Closed |
2004-03-18
|
|
303993455
|
0419700
|
2003-05-29
|
1630 WOODPECKER LANE, MIDDLEBURG, FL, 32068
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2003-05-29
|
Emphasis |
L: FALL, S: CONSTRUCTION
|
Case Closed |
2003-08-20
|
|
303983332
|
0419700
|
2001-02-12
|
3176 OLD JENNINGS ROAD, MIDDLEBURG, FL, 32068
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2001-02-15
|
Emphasis |
L: FALL, L: FLCARE, S: CONSTRUCTION
|
Case Closed |
2001-02-16
|
|