Search icon

QUALITY METAL FABRICATORS, INC. - Florida Company Profile

Company Details

Entity Name: QUALITY METAL FABRICATORS, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

QUALITY METAL FABRICATORS, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 15 Mar 1983 (42 years ago)
Last Event: AMENDMENT
Event Date Filed: 25 Apr 2005 (20 years ago)
Document Number: G28026
FEI/EIN Number 592264091

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2610 E 5TH AVE, TAMPA, FL, 33605, US
Mail Address: 2610 E 5TH AVE, TAMPA, FL, 33605, US
ZIP code: 33605
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
Roberts Earl RIII President 2610 E 5TH AVE, TAMPA, FL, 33605
ROBERTS STEPHEN President 2610 E 5TH AVE, TAMPA, FL, 33605
JONAS, BRUCE Agent 16017 N. FLORIDA STE#125, LUTZ, FL, 33549
BURGESS JASON President 2610 E 5TH AVE, TAMPA, FL, 33605

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2009-01-14 JONAS, BRUCE -
REGISTERED AGENT ADDRESS CHANGED 2005-08-25 16017 N. FLORIDA STE#125, LUTZ, FL 33549 -
AMENDMENT 2005-04-25 - -
CHANGE OF PRINCIPAL ADDRESS 2003-04-28 2610 E 5TH AVE, TAMPA, FL 33605 -
CHANGE OF MAILING ADDRESS 2003-04-28 2610 E 5TH AVE, TAMPA, FL 33605 -

Documents

Name Date
ANNUAL REPORT 2024-02-08
ANNUAL REPORT 2023-01-31
ANNUAL REPORT 2022-02-01
ANNUAL REPORT 2021-04-28
ANNUAL REPORT 2020-03-17
ANNUAL REPORT 2019-02-07
ANNUAL REPORT 2018-02-19
ANNUAL REPORT 2017-02-07
ANNUAL REPORT 2016-03-01
ANNUAL REPORT 2015-01-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344543152 0420600 2020-01-02 2610 EAST 5TH AVE, TAMPA, FL, 33605
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2020-01-02
Emphasis L: HINOISE
Case Closed 2020-06-29

Related Activity

Type Referral
Activity Nr 1526857
Health Yes
Type Inspection
Activity Nr 1450674
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100095 C01
Issuance Date 2020-05-13
Abatement Due Date 2020-06-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-10
Nr Instances 2
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: For employees working in the fabrication area they were over exposed to noise levels over 85 decibels for the OSHA TWA, as observed on or about February 11, 2020: a) For the employee exposed to noise at 66% dose of the permissible daily noise exposure limit (8-hour time-weighted-average level 0f 85 dBA), or an equivalent sound level of 88.1 dBA for the 411 minute sampling period. This exposure calculation included a zero increment for the 57 minutes not sampled. b) For the employee exposed to noise at 60% dose of the permissible daily noise exposure limit (8-hour time-weighted-average level 0f 85 dBA), or an equivalent sound level of 87.6 dBA during the 400 minute sampling period. This exposure calculation included a zero increment for the 60 minutes not sampled.
Citation ID 01002
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2020-05-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-10
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) For employees fabricating Carbon and Alloy Steel Rebar at the production bay, as noted on or about 01/02/2020. No written hazard communication program was in place for employees cutting, bending and bundling rebar containing metal such as but not limited to lead, manganese and iron.
Citation ID 01003
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2020-05-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-10
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) For employees fabricating Carbon and Alloy Steel Rebar at the production bay, training was not conducted on the hazards associated to rebar which amongst other compounds contains lead, chromium and manganese, as observed on or about January 02, 2020.
344506746 0420600 2019-12-12 2610 EAST 5TH AVE, TAMPA, FL, 33605
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2020-05-08
Emphasis N: AMPUTATE, L: FORKLIFT, P: AMPUTATE
Case Closed 2022-07-26

Related Activity

Type Inspection
Activity Nr 1454315
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100147 C04 II D
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 2024.0
Initial Penalty 4048.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures: a. On or about 12/12/2019, at the fabrication area, employees were exposed to the inadvertent start-up or release of energy during maintenance of equipment such as but not limited to the Shear Lines and conveyor tables, cutting, bending and coil machines, in that, the energy control procedures did not have steps for testing machines or equipment to determine that the isolation for the control of an energy source such as electrical, hydraulic and pneumatic was effective.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. On or about 12/12/2019, at the fabrication area, employees were exposed to the inadvertent start-up or release of energy during maintenance of equipment such as but not limited to the Shear Lines and conveyor tables, cutting, bending and coil machines, in that, the energy control procedures were not inspected at least annually as required.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100147 D01
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(d)(1): The authorized employee did not have knowledge of the magnitude of the energy before the authorized or affected employee turned off a machine or equipment: a. On or about 12/12/2019, at the fabrication area, employees were exposed to the inadvertent start-up or release of energy during maintenance of equipment such as but not limited to the Shear Lines and conveyor tables, cutting, bending and coil machines, in that, the energy control procedures did not include the magnitude of all energy sources.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100178 L01 II
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 2024.0
Initial Penalty 4048.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck: a. On or about 12/12/2019, at the yard area, employees were exposed to the hazard of being crushed by the load during forklift operations, in that, employees operating forklifts were not provided training since 2008.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100178 L04 III
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a. On or about 12/12/2019, at the yard area, employees were exposed to the hazard of being crushed by the load during forklift operations, in that, an evaluation of the forklift operator's performance was not conducted since 2008.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2020-05-19
Abatement Due Date 2020-07-22
Current Penalty 4723.0
Initial Penalty 9446.0
Final Order 2020-06-15
Nr Instances 7
Nr Exposed 25
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. On or about 12/12/2019, at the fabrication area, employees were exposed to the point of operation, in that, the Concept 91 MEP Bending Machine did not have a guard at the point of operation. b. On or about 12/12/2019, at the fabrication area, employees were exposed to the point of operation, in that, the small MEP bending machine (mini max 85 V machine), did not have a guard at the point of operation. c. On or about 12/12/2019, at the fabrication area, employees were exposed to the point of operation, in that, the 3 RMS 11 rebar bending machines did not have a guard at the point of operation. d. On or about 12/12/2019, at the fabrication area, employees were exposed to the point of operation, in that, the Arnold 8 rebar bending machine did not have a guard at the point of operation. e. On or about 12/12/2019, at the fabrication area, employees were exposed to the point of operation, in that, the RMS 14 rebar bending machine did not have a guard at the point of operation. f. On or about 12/12/2019, at the fabrication area, employees were exposed to the point of operation, in that, the CRS 18 rebar bending machine did not have a guard at the point of operation. g. On or about 12/12/2019, at the fabrication area shear line "1", employees were exposed to the point of operation, in that, the guard at the point of operation was tied in the up position exposing employees to the moving parts.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2020-05-19
Abatement Due Date 2020-07-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 3
Nr Exposed 25
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points and rotating parts: a. On or about 12/12/2019, at the fabrication area near the small MEP bending machine, employees were exposed to the rotating guide pulleys, in that, a guard was not provided over the rotating parts. b. On or about 12/12/2019, at the fabrication area under RMS 14 bending machine, employees were exposed to rotating parts under the machine at the operator's side, in that, the guard enclosing the front of the machine was removed and not replaced. c. On or about 12/12/2019, at the fabrication area shear line 1, employees were exposed to a struck by hazard, in that, at the side of the shear line table two guards were missing exposing employees to the rotating parts at the side of the table.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100219 D01
Issuance Date 2020-05-19
Abatement Due Date 2020-07-22
Current Penalty 2024.0
Initial Penalty 4048.0
Final Order 2020-06-15
Nr Instances 3
Nr Exposed 25
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a. On or about 12/12/2019, at the fabrication area shear line 1, employees were exposed to a struck by hazard, in that, a series of pulleys at the side of the shear line table did not have a guard to fully enclose the moving parts. b. On or about 12/12/2019, at the fabrication area shear line 2, employees were exposed to a struck by hazard, in that, two pulleys at the side of the shear line table below the point of operation guard did not have a guard to fully enclose the moving parts. c. On or about 12/12/2019, at the fabrication area shear line 2, employees were exposed to a struck by hazard, in that, a series of pulleys at the side of the shear line table did not have a guard to fully enclose the moving parts.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100219 E01 I
Issuance Date 2020-05-19
Abatement Due Date 2020-07-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 2
Nr Exposed 25
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): a. On or about 12/12/2019, at the fabrication area shear line 1, employees were exposed to caught-in and struck by hazards, in that, a series of belts at the side of the shear line table did not have a guard to fully enclose the moving parts. b. On or about 12/12/2019, at the fabrication area shear line 2, employees were exposed to caught-in and struck by hazards, in that, a series of belts at the side of the shear line table did not have a guard to fully enclose the moving parts.
Citation ID 01004C
Citaton Type Serious
Standard Cited 19100219 E03 I
Issuance Date 2020-05-19
Abatement Due Date 2020-07-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a. On or about 12/12/2019, at the fabrication area shear line 2, employees were exposed to a caught-in and struck by hazards, in that, a vertical belt at the side of the shear line below the point of operation guard did not have a guard to fully enclose the moving parts.
Citation ID 01004D
Citaton Type Serious
Standard Cited 19100219 F03
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: a. On or about 12/12/2019, at the fabrication area, under the CRS 18 bending machine, employees were exposed to caught in and struck by hazards, in that, a chain and sprocket under the bending machine were not enclosed with a guard as required.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19100303 B01 II
Issuance Date 2020-05-19
Abatement Due Date 2021-12-01
Current Penalty 2699.0
Initial Penalty 5398.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: a. On or about 12/12/2019, at the fabrication area, S-11 column, employees were exposed to electrical hazards, in that, a breaker panel with 14 breakers and a breaker panel with 7 breakers were not provided with a cover door, were corroded, and were subject to getting wet. The panel with 14 breakers was damaged and bent on the left side.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19100303 B02
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 2
Nr Exposed 25
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. On or about 12/12/2019, at the fabrication break area, employees were exposed to electrical hazards, in that, a six outlet extension strip was used by being mounted on the exterior I beams at a location where it could get wet. The multi-outlet strip is not designed for exterior use at wet locations. b. On or about 12/12/2019, at the fabrication area shear line 3, employees were exposed to electrical hazards, in that, a 4-way outlet box without a cover was used while mounted at a location where it could get wet. The multi-outlet box did not have a cover as designed to keep the live conductors from getting wet during inclement weather conditions.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100303 F02
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 2024.0
Initial Penalty 4048.0
Final Order 2020-06-15
Nr Instances 5
Nr Exposed 25
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a. On or about 12/12/2019, at the fabrication area near the MEP bending machines, employees were exposed to electrical hazards, in that, a breaker panel with 9 breakers did not have labels to indicate their purpose. b. On or about 12/12/2019, at the fabrication area S-11 column, employees were exposed to electrical hazards, in that, a breaker panel with 14 breakers did not have labels to indicate their purpose. c. On or about 12/12/2019, at the fabrication area S-11 column, employees were exposed to electrical hazards, in that, a breaker panel with 7 breakers did not have labels to indicate their purpose. d. On or about 12/12/2019, at the fabrication area S-17 column, employees were exposed to electrical hazards, in that, two main disconnects did not have labels to indicate their purpose. e. On or about 12/12/2019, at the fabrication area east wall S-21 column, employees were exposed to electrical hazards, in that, two breaker panes had a total of 15 breakers without a label to indicate their purpose.
Citation ID 01007
Citaton Type Serious
Standard Cited 19100305 B01 II
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 2699.0
Initial Penalty 5398.0
Final Order 2020-06-15
Nr Instances 3
Nr Exposed 25
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. On or about 12/12/2019, at the fabrication area near the MEP bending machines, employees were exposed to electrical hazards, in that, a 240 volts main power disconnect was missing a panel cover and had 3 breaker openings without a cover. b. On or about 12/12/2019, at the fabrication area near column N-11, employees were exposed to electrical hazards, in that, a 240 volts control panel had an opening of 3 inches by 2 inches without a cover. c. On or about 12/12/2019, at the fabrication area near MEP 91, employees were exposed to electrical hazards, in that, a 240 volt red breaker box had a knockout missing from the side of the box.
Citation ID 01008
Citaton Type Serious
Standard Cited 19100305 G02 III
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 2024.0
Initial Penalty 4048.0
Final Order 2020-06-15
Nr Instances 5
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a. On or about 12/12/2019, at the fabrication area near the Concept 91 MEP Bending Machine workstation, employees were exposed to electrical hazards, in that, the wiring to the machine from the main disconnect was without strain relief. b. On or about 12/12/2019, at the fabrication area main control panel, S-14 column, employees were exposed to electrical hazards, in that, wiring at the top of the panel inside a conduit had the conduit broken off and out of the panel and pull could be transmitted to the wiring's terminal screws. c. On or about 12/12/2019, at the fabrication area, employees were exposed to machine hazards, in that, the wiring to the foot pedal control for the RMS 14 rebar bending machine did not have strain relief. d. On or about 12/12/2019, at the fabrication area, employees were exposed to machine hazards, in that, the wiring to the foot pedal control for the RMS 11 rebar bending machine did not have strain relief. e. On or about 12/12/2019, at the fabrication area Shear line 2 control panel, employees were exposed to electrical hazards, in that, the wiring entering the power control panel at the side of the shear line was not provided with strain relief.
Citation ID 02001
Citaton Type Other
Standard Cited 19100022 A01
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces were kept in a clean, orderly, and sanitary condition: a. On or about 12/12/2019, at the fabrication area, around the various types of machines and equipment, good housekeeping was not maintained, in that, metal dust and scaling as well as pieces of scrap metal were allowed to accumulate.
Citation ID 02002
Citaton Type Other
Standard Cited 19100025 B03
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.25(b)(3): The employer did not ensure that the stairs had uniform riser heights and tread depths between the landings: a. On or about 12/12/2019, at the fabrication area loading door platform, employees were exposed to a fall hazard when gaining access to the platform, in that, two mobile stairways were permanently installed at the ends of the platform for access which were in disrepair and bent and had uneven stair risers ranging from 8 inches to 12.5 inches high.
Citation ID 02003
Citaton Type Other
Standard Cited 19100025 C02
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.25(c)(2): The employer did not ensure standard stairs have a maximum riser height of 9.5 inches (24 cm): a. On or about 12/12/2019, at the fabrication area loading door platform, employees were exposed to a fall hazard when gaining access to the platform, in that, two mobile stair ways were permanently installed at the ends of the platform for access which were in disrepair and bent and had uneven stair risers with a maximum riser height of 12.5 inches high.
Citation ID 02004
Citaton Type Other
Standard Cited 19100028 B03 II
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.28(b)(3)(ii): The employer did not ensure each employee is protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems: a. On or about 12/12/2019, at the fabrication area loading door platform, employees were exposed to a tripping hazard, in that, a floor hole at the west side of the platform measured to be 8 inches by 6 inches located in front of the stairway was not covered.
Citation ID 02005
Citaton Type Other
Standard Cited 19100028 B11 II
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.28(b)(11)(ii): Each flight of stairs having at least 3 treads and at least 4 risers was not equipped with stair rail systems and handrails as required in Table D-2 of this standard: a. On or about 12/12/2019, at the fabrication area loading door platform, employees were exposed to a fall hazard when gaining access to the platform, in that, two mobile stair ways were permanently installed at the ends of the platform for access which were in disrepair and bent and had a single railing designed for a mobile stairway.
Citation ID 02006
Citaton Type Other
Standard Cited 19100157 E02
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a. On or about 12/12/2019, at the fabrication area, fire extinguishers were not inspected monthly as required.
Citation ID 02007
Citaton Type Other
Standard Cited 19100157 E03
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a. On or about 12/12/2019, at the fabrication area, fire extinguishers were not inspected annually as required.
Citation ID 02008
Citaton Type Other
Standard Cited 19100178 A04
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a. On or about 12/12/2019, at the yard area where forklift operations were conducted, employees were exposed to the hazard of operating a Ring forklift with extension attachments to the forks without having the manufacturer approval to assure the safe operation and use of the forklift.
Citation ID 02009
Citaton Type Other
Standard Cited 19100179 J02 III
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier of the hook inspected, were not performed: a. On or about 12/12/2019, at the fabrication area, employees were exposed to a struck by hazard, in that, the crane hoists used to handle material were not inspected frequently as required. Frequent inspections to include daily and monthly inspections of the cranes and lifting apparatus were not conducted to include the lifting hooks and assure the hook safety latches were operational.
Citation ID 02010
Citaton Type Other
Standard Cited 19100219 C04 I
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) projected more than one half the diameter of the shaft: a. On or about 12/12/2019, at the fabrication area shear line 2, employees were expose to a struck by hazard, in that, a one inch in diameter rotating shaft end protruded 2 inches without a guard.
Citation ID 02011
Citaton Type Other
Standard Cited 19100253 A03
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(a)(3): Apparatus such as torches, regulators or pressure-reducing valves, acetylene generators, and manifolds used in an oxygen-fuel gas system had not been approved: a. On or about 12/12/2019, at the fabrication area, employees were exposed to a fire hazard, in that, the oxygen-acetylene manifold was not equipped with an approved gauge. The acetylene gauge used was broken and not replaced.
Citation ID 02012
Citaton Type Other
Standard Cited 19100303 B08 I
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 378.5
Initial Penalty 757.0
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(8)(i): Electrical equipment was not firmly secured to the surface on which it was mounted: a. On or about 12/12/2019, at the fabrication area CRS 18 bending machine, employees were exposed to electrical hazards, in that, the operating console for the machine was broken off its support post and was loosely suspended by having a wire wrapped around it.
Citation ID 02013
Citaton Type Other
Standard Cited 19100304 G05
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 2
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. On or about 12/12/2019, at the fabrication area near the small MEP bending machine, employees were exposed to electrical hazards, in that, the wiring to the fan had a prong that was missing the ground prong. b. On or about 12/12/2019, at the fabrication area employees were exposed to electrical hazards, in that, the wiring to the welder had a prong that was missing the ground prong.
Citation ID 02014
Citaton Type Other
Standard Cited 19100305 G01 IV A
Issuance Date 2020-05-19
Abatement Due Date 2020-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-15
Nr Instances 3
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. On or about 12/12/2019, at the fabrication area near the Concept 91 MEP Bending Machine workstation, employees were exposed to electrical hazards, in that an extension cord was used in place of fixed wiring to run a fan and a speaker. b. On or about 12/12/2019, at the fabrication area near the small MEP Bending Machine workstation, employees were exposed to electrical hazards, in that an extension cord was used in place of fixed wiring to run a fan. c. On or about 12/12/2019, south-east side of the fabrication area, employees were exposed to electrical hazards, in that, two extension cords were plugged on a receptacle mounted on an exterior beam and were used in place of fixed wiring.
109201210 0420600 1995-04-26 5353 W. TYSON RD, TAMPA, FL, 33611
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 1995-05-01
Case Closed 1995-06-14

Related Activity

Type Referral
Activity Nr 901678441
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100095 C01
Issuance Date 1995-05-12
Abatement Due Date 1995-06-13
Current Penalty 750.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 6
Gravity 01
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100095 D01
Issuance Date 1995-05-12
Abatement Due Date 1995-06-14
Nr Instances 3
Nr Exposed 6
Related Event Code (REC) Referral
Gravity 01
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100095 G01
Issuance Date 1995-05-12
Abatement Due Date 1995-06-14
Nr Instances 6
Nr Exposed 6
Related Event Code (REC) Referral
Gravity 01
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100095 K01
Issuance Date 1995-05-12
Abatement Due Date 1995-06-14
Nr Instances 6
Nr Exposed 6
Related Event Code (REC) Referral
Gravity 01
Citation ID 01001E
Citaton Type Serious
Standard Cited 19100095 I02 I
Issuance Date 1995-05-12
Abatement Due Date 1995-06-14
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 01
109711929 0420600 1995-03-31 5353 W. TYSON RD, TAMPA, FL, 33611
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 1995-04-12
Case Closed 1995-09-06

Related Activity

Type Complaint
Activity Nr 77060754
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100133 A01
Issuance Date 1995-06-29
Abatement Due Date 1995-07-06
Current Penalty 500.0
Initial Penalty 525.0
Nr Instances 1
Nr Exposed 28
Related Event Code (REC) Complaint
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 1995-06-29
Abatement Due Date 1995-08-02
Current Penalty 500.0
Initial Penalty 875.0
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 03
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100178 L
Issuance Date 1995-06-29
Abatement Due Date 1995-08-16
Current Penalty 500.0
Initial Penalty 1750.0
Nr Instances 1
Gravity 10
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100178 P01
Issuance Date 1995-06-29
Abatement Due Date 1995-08-01
Nr Instances 2
Nr Exposed 28
Gravity 10
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 1995-06-29
Abatement Due Date 1995-07-12
Current Penalty 500.0
Initial Penalty 875.0
Nr Instances 2
Nr Exposed 4
Gravity 03
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100219 B01
Issuance Date 1995-06-29
Abatement Due Date 1995-07-12
Nr Instances 1
Nr Exposed 3
Gravity 03
Citation ID 01005A
Citaton Type Serious
Standard Cited 19100305 A01 I
Issuance Date 1995-06-29
Abatement Due Date 1995-07-19
Current Penalty 500.0
Initial Penalty 875.0
Nr Instances 4
Nr Exposed 28
Gravity 03
Citation ID 01005B
Citaton Type Serious
Standard Cited 19100305 B01
Issuance Date 1995-06-29
Abatement Due Date 1995-07-19
Nr Instances 2
Nr Exposed 28
Gravity 03
Citation ID 01005C
Citaton Type Serious
Standard Cited 19100305 B02
Issuance Date 1995-06-29
Abatement Due Date 1995-07-19
Nr Instances 2
Nr Exposed 28
Gravity 03
Citation ID 01005D
Citaton Type Serious
Standard Cited 19100305 G02 III
Issuance Date 1995-06-29
Abatement Due Date 1995-07-19
Nr Instances 2
Nr Exposed 28
Gravity 03
Citation ID 01006A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 1995-06-29
Abatement Due Date 1995-08-16
Current Penalty 500.0
Initial Penalty 875.0
Nr Instances 1
Nr Exposed 28
Gravity 03
Citation ID 01006B
Citaton Type Serious
Standard Cited 19101200 F05 I
Issuance Date 1995-06-29
Abatement Due Date 1995-08-16
Nr Instances 1
Nr Exposed 28
Gravity 03
Citation ID 01006C
Citaton Type Serious
Standard Cited 19101200 G01
Issuance Date 1995-06-29
Abatement Due Date 1995-08-16
Nr Instances 1
Nr Exposed 28
Gravity 03
Citation ID 01006D
Citaton Type Serious
Standard Cited 19101200 H
Issuance Date 1995-06-29
Abatement Due Date 1995-08-16
Nr Instances 1
Nr Exposed 28
Gravity 03
Citation ID 02001A
Citaton Type Other
Standard Cited 19040002 A
Issuance Date 1995-06-29
Abatement Due Date 1995-08-16
Nr Instances 1
Nr Exposed 28
Gravity 01
Citation ID 02001B
Citaton Type Other
Standard Cited 19040007
Issuance Date 1995-06-29
Abatement Due Date 1995-08-16
Nr Instances 1
Nr Exposed 28
Gravity 01
106313513 0420600 1988-11-18 5811 10TH AVE., TAMPA,, FL, 33619
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 1988-11-18
Case Closed 1989-02-10

Related Activity

Type Complaint
Activity Nr 72469752
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100133 A01
Issuance Date 1989-01-17
Abatement Due Date 1989-01-23
Current Penalty 50.0
Initial Penalty 60.0
Nr Instances 1
Nr Exposed 1
Gravity 03
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 1989-01-17
Abatement Due Date 1989-01-30
Current Penalty 50.0
Initial Penalty 100.0
Nr Instances 1
Nr Exposed 1
Gravity 05
Citation ID 01003A
Citaton Type Other
Standard Cited 19100219 D01
Issuance Date 1989-01-17
Abatement Due Date 1989-01-30
Current Penalty 50.0
Initial Penalty 60.0
Nr Instances 1
Nr Exposed 2
Gravity 02
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100219 E01 I
Issuance Date 1989-01-17
Abatement Due Date 1989-01-30
Nr Instances 1
Nr Exposed 2
Citation ID 02001
Citaton Type Other
Standard Cited 19030002 A01
Issuance Date 1989-01-17
Abatement Due Date 1989-01-19
Nr Instances 1
Nr Exposed 7
Citation ID 02002
Citaton Type Other
Standard Cited 19100157 D03 I
Issuance Date 1989-01-17
Abatement Due Date 1989-01-30
Nr Instances 2
Nr Exposed 4
Citation ID 02003
Citaton Type Other
Standard Cited 19100309 B
Issuance Date 1989-01-17
Abatement Due Date 1989-01-23
Nr Instances 1
Nr Exposed 4

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
2871767102 2020-04-11 0455 PPP 2610 East 5th Avenue, TAMPA, FL, 33605-5504
Loan Status Date 2021-05-14
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 442602
Loan Approval Amount (current) 442602
Undisbursed Amount 0
Franchise Name -
Lender Location ID 45120
Servicing Lender Name Valley National Bank
Servicing Lender Address 615 Main Ave, PASSAIC, NJ, 07055-5066
Rural or Urban Indicator U
Hubzone Y
LMI Y
Business Age Description Existing or more than 2 years old
Project Address TAMPA, HILLSBOROUGH, FL, 33605-5504
Project Congressional District FL-14
Number of Employees 34
NAICS code 332312
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Subchapter S Corporation
Originating Lender ID 45120
Originating Lender Name Valley National Bank
Originating Lender Address PASSAIC, NJ
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 446819.01
Forgiveness Paid Date 2021-03-31
3945158809 2021-04-15 0455 PPS 2610 E 5th Ave, Tampa, FL, 33605-5504
Loan Status Date 2022-01-14
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 295030
Loan Approval Amount (current) 295030
Undisbursed Amount 0
Franchise Name -
Lender Location ID 45120
Servicing Lender Name Valley National Bank
Servicing Lender Address 615 Main Ave, PASSAIC, NJ, 07055-5066
Rural or Urban Indicator U
Hubzone Y
LMI Y
Business Age Description Existing or more than 2 years old
Project Address Tampa, HILLSBOROUGH, FL, 33605-5504
Project Congressional District FL-14
Number of Employees 19
NAICS code 332312
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Subchapter S Corporation
Originating Lender ID 45120
Originating Lender Name Valley National Bank
Originating Lender Address PASSAIC, NJ
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 297021.45
Forgiveness Paid Date 2021-12-16

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
1023510 Intrastate Non-Hazmat 2023-10-23 60000 2022 0 2 Private(Property)
Legal Name QUALITY METAL FABRICATORS INC
DBA Name -
Physical Address 2610 E 5TH AVE, TAMPA, FL, 33605, US
Mailing Address 2610 E 5TH AVE, TAMPA, FL, 33605, US
Phone (813) 831-7320
Fax (813) 831-3436
E-mail HDIXSON@QMFGROUP.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 02 May 2025

Sources: Florida Department of State