Search icon

G&R MINERAL SERVICES, INC. - Florida Company Profile

Company Details

Entity Name: G&R MINERAL SERVICES, INC.
Jurisdiction: FLORIDA
Filing Type: Foreign Profit
Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 30 Apr 1998 (27 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 06 Jan 2000 (25 years ago)
Document Number: F98000002465
FEI/EIN Number 630972149

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2355 ALTON RD., BIRMINGHAM, AL, 35210
Mail Address: P.O. BOX 100939, BIRMINGHAM, AL, 35210-0939
Place of Formation: ALABAMA

Key Officers & Management

Name Role Address
LOVE JIM President 2355 ALTON RD., BIRMINGHAM, AL, 35210
WASHBURN BEVERLY A Secretary 2355 ALTON RD., BIRMINGHAM, AL, 35210
HADDAD THOMAS Vice President 2355 ALTON RD., BIRMINGHAM, AL, 35210
Kressly Timothy P Agent 7993 NW 60th Street, Miami, FL, 33166

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2017-01-04 Kressly , Timothy P -
REGISTERED AGENT ADDRESS CHANGED 2017-01-04 7993 NW 60th Street, Miami, FL 33166 -
CHANGE OF MAILING ADDRESS 2006-01-23 2355 ALTON RD., BIRMINGHAM, AL 35210 -
REINSTATEMENT 2000-01-06 - -
REVOKED FOR ANNUAL REPORT 1999-09-24 - -

Documents

Name Date
ANNUAL REPORT 2024-02-06
ANNUAL REPORT 2023-01-25
ANNUAL REPORT 2022-01-24
ANNUAL REPORT 2021-01-12
ANNUAL REPORT 2020-01-14
ANNUAL REPORT 2019-02-07
ANNUAL REPORT 2018-01-15
ANNUAL REPORT 2017-01-04
ANNUAL REPORT 2016-01-21
ANNUAL REPORT 2015-01-12

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346888159 0418800 2023-08-04 2600 EISENHOWER BLVD., FORT LAUDERDALE, FL, 33316
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2023-08-04

Related Activity

Type Inspection
Activity Nr 1688816
Safety Yes
Type Accident
Activity Nr 2063860
Type Inspection
Activity Nr 1688814
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C04 II
Issuance Date 2024-02-01
Abatement Due Date 2024-02-28
Current Penalty 11292.0
Initial Penalty 11292.0
Contest Date 2024-03-04
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: (a) On or about August 4, 2023, and at times prior to, at 2600 Eisenhower Blvd., Fort Lauderdale, FL 33316, South Cross Screw area, employees were exposed to amputation and electrical hazards, in that the employer did not ensure that the lockout/tagout procedure(s) for the south screw described the scope, the type and magnitude of the participating hazardous energies, the location and identity of the disconnecting means, and the specific steps for shutting down and controlling hazardous energy, the placement and removal of lockout/tagout devices, and the testing of equipment during assembly and adjustment.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100147 F01 II
Issuance Date 2024-02-01
Abatement Due Date 2024-03-20
Current Penalty 16131.0
Initial Penalty 16131.0
Contest Date 2024-03-04
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(f)(1)(ii): When lockout or tagout devices were temporarily removed from the energy isolating device and the machine or equipment was energized to test or position the machine, equipment, or component thereof, the employees were not removed from the machine or equipment area in accordance with paragraph (e)(2) of this section: a) On or about August 4, 2023, at 2600 Eisenhower Blvd., Fort Lauderdale, FL 33316, South Cross Screw area, employees were exposed to caught-in and amputation hazards, in that the employer did not ensure employees were removed from the unguarded screw area at the time locks were removed and the screw was re-energized and rotated.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100147 F02 I
Issuance Date 2024-02-01
Abatement Due Date 2024-03-20
Current Penalty 11292.0
Initial Penalty 11292.0
Contest Date 2024-03-04
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(f)(2)(i): When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures: a) On or about August 4, 2023, at 2600 Eisenhower Blvd., Fort Lauderdale, FL 33316, South Cross Screw area, employees were exposed to caught-in and amputation hazards, in that the onsite employer and the outside employer did not review and coordinate in advance the lockout or tagout procedures and the methods for lock removal, power reconnection, and controlled rotation of the unguarded screw.

Date of last update: 02 Apr 2025

Sources: Florida Department of State