346334535
|
0420600
|
2022-11-09
|
5801 COMMERCE ST., TAMPA, FL, 33616
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-11-09
|
Case Closed |
2023-03-16
|
Related Activity
Type |
Referral |
Activity Nr |
1965807 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100147 D04 I |
Issuance Date |
2023-01-26 |
Abatement Due Date |
2023-02-07 |
Current Penalty |
15625.0 |
Initial Penalty |
15625.0 |
Final Order |
2023-02-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) On or about 11/5/2022, at 5801 West Commerce Street, concrete batch plant, an employee was exposed to an amputation hazard while lubricating the interior of a batch plant mixer, in that, lock out/tag out was not utilized. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100147 C07 IV |
Issuance Date |
2023-01-26 |
Abatement Due Date |
2023-02-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-02-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date: a. On or about 11/5/2022, at 5801 West Commerce Street, concrete batch plant, the employer did not certify that lock out tag out training was conducted for employees exposed to amputation/ crushing hazards while lubricating and climbing into the interior of a batch plant mixer. |
|
|
344885173
|
0420600
|
2020-08-17
|
5801 COMMERCE ST., TAMPA, FL, 33616
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-08-17
|
Case Closed |
2020-12-21
|
Related Activity
Type |
Complaint |
Activity Nr |
1640012 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2020-12-03 |
Current Penalty |
4626.6 |
Initial Penalty |
7711.0 |
Final Order |
2020-12-18 |
Nr Instances |
3 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On or about 08/17/2020, by the concrete form area, a 110VAC plug box used by employees was not effectively secured to its mount resulting in an opening/gap where its inner wiring was exposed to the elements. A metal wire had also been wrapped inside the exposed opening/gap and protruded out of the opening/gap. This condition exposed employees to electric shock hazards. b) On or about 08/17/2020, by the concrete form area, a 110VAC breaker box had a 7/16 inch opening next to an electrical plug exposing its inner wiring to the elements. This condition exposed employees to electrical shock hazards. c) On or about 08/17/2020, by the concrete form area, multiple 110VAC electrical boxes had unused, open knockouts on the bottom side of the boxes exposing inner wiring to the elements. This condition exposed employees to electrical shock hazards. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100305 B01 I |
Issuance Date |
2020-12-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-12-18 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: a) On or about 08/17/2020, as observed at the concrete form area, conduit entering an electrical box was not fitted to the electrical box resulting in potential abrasion to the internal wiring. |
|
|
344186184
|
0420600
|
2019-07-24
|
5801 COMMERCE ST., TAMPA, FL, 33616
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-07-24
|
Emphasis |
L: FORKLIFT, N: AMPUTATE
|
Case Closed |
2019-12-23
|
Related Activity
Type |
Complaint |
Activity Nr |
1475887 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100305 E02 |
Issuance Date |
2019-12-10 |
Abatement Due Date |
2019-12-20 |
Current Penalty |
7956.0 |
Initial Penalty |
13260.0 |
Final Order |
2019-12-20 |
Nr Instances |
1 |
Nr Exposed |
20 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(e)(2): Switches, circuit breakers and switchboards installed in wet locations were not enclosed in weatherproof enclosures: a) For employees working in the outdoor manufacturing area known as the "boneyard", at the location in Tampa, as observed on or about July 24, 2019. A clamp type non weatherproof box connector was used to connect a temporary power source for a rebar ender machine. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100305 J02 VII |
Issuance Date |
2019-12-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-12-20 |
Nr Instances |
1 |
Nr Exposed |
20 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(j)(2)(vii): A receptacle installed in a wet location where the product intended to be plugged into it was to be attended while in use (for example, portable tools) did not have an enclosure that was weatherproof when the attachment plug cap was removed: a) For employees working in the outdoor manufacturing area known as the "boneyard", at the location in Tampa, as observed on or about July 24, 2019. A 220 volt receptacle that was not in use did not have the cover attached. The receptacle was located in a standing water location with employees working in the immediate area. |
|
|
343059218
|
0420600
|
2018-04-03
|
5801 WEST COMMERCE STREET, TAMPA, FL, 33616
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-04-03
|
Case Closed |
2018-10-24
|
Related Activity
Type |
Referral |
Activity Nr |
1322633 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
5A0001 |
Issuance Date |
2018-09-28 |
Abatement Due Date |
2018-10-18 |
Current Penalty |
6467.0 |
Initial Penalty |
12934.0 |
Final Order |
2018-10-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by and crush-by hazards: a) At the Tampa Florida jobsite plant, employees were exposed to struck-by hazard while performing ground man duties near suspended loads of the 50 Ton Shuttle Lift Overhead Gantry Crane which is used to move large, heavy loads such as , but not limited to, 35 Ton pre-stressed concrete piles. These loads were elevated to be lowered and guided by ground men onto dunnage support points. The workers movement between the suspended loads and stationary piles increases the potential of exposure. |
|
|
339842098
|
0420600
|
2014-07-08
|
5801 COMMERCE STREET, TAMPA, FL, 33616
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-07-08
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2014-08-21
|
Related Activity
Type |
Complaint |
Activity Nr |
896665 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100178 P01 |
Issuance Date |
2014-07-30 |
Current Penalty |
2400.0 |
Initial Penalty |
4000.0 |
Final Order |
2014-08-20 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a) For the Standard Concrete Products facility as observed on or about 07/08/2014, a TCM forklift, model number FD70Z8T, had a missing acceleration pedal and exposed control wiring. This condition resulted in potential struck by hazards. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100178 A06 |
Issuance Date |
2014-07-30 |
Abatement Due Date |
2014-09-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-08-20 |
Nr Instances |
1 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were not maintained in a legible condition: a) For the Standard Concrete Products facility as observed on or about 07/08/2014, nameplates on a TCM forklift (model # FD70Z8T) containing load capacity information and forklift weight information were not legible. In addition, it had missing labeling for its operational controls. |
|
|
307402883
|
0420600
|
2004-02-27
|
5801 W. COMMERCE ST., TAMPA, FL, 33616
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2004-02-27
|
Emphasis |
N: SILICA, S: SILICA, L: CONCRETE
|
Case Closed |
2004-04-14
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100022 D01 |
Issuance Date |
2004-03-11 |
Abatement Due Date |
2004-04-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100212 B |
Issuance Date |
2004-03-11 |
Abatement Due Date |
2004-04-13 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
01 |
|
|
304708274
|
0420600
|
2001-08-22
|
5801 W. COMMERCE ST., TAMPA, FL, 33616
|
|
Inspection Type |
Accident
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2002-02-20
|
Case Closed |
2002-07-05
|
Related Activity
Type |
Accident |
Activity Nr |
102329828 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100212 A01 |
Issuance Date |
2002-02-20 |
Abatement Due Date |
2002-03-25 |
Current Penalty |
2125.0 |
Initial Penalty |
2125.0 |
Contest Date |
2002-03-13 |
Final Order |
2002-07-05 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
03 |
Hazard |
STRUCK BY |
|
|