Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-04-14
|
Emphasis |
L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2017-07-14
|
Related Activity
Type |
Inspection |
Activity Nr |
1057195 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2015-08-19 |
Nr Instances |
8 |
Nr Exposed |
50 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: the employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck by hazard: a. At the perimeter of the refurbishing building, employees were exposed to a struck by hazard, in that, the canopies constructed around the building were supported by a stack of pallets and were constructed by splicing pallet wood and other scrap wood causing them to have sagging roofs which were leaning, on or about 03/18/2015. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100023 C03 |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-24 |
Current Penalty |
2100.0 |
Initial Penalty |
3500.0 |
Final Order |
2015-08-19 |
Nr Instances |
3 |
Nr Exposed |
50 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board: a. At the de-stacking line, employees were exposed to falling on the live roller conveyor, in that, two catwalks located one at 51 inches and the other at 91 inches directly over the conveyor were not provided with standard railings to include a midrail and a toe board, on or about 03/18/2015. b. At the end of the refurbishing line near the stacking area, employees were exposed to falling on the live roller conveyor, in that, the catwalk directly over the conveyor was not provided with standard railings to include a midrail and a toe board, on or about 03/18/2015. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100132 D01 |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
2520.0 |
Initial Penalty |
4200.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
50 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment: a. At the pallet refurbishing areas, a personal protective equipment hazard assessment was not conducted to evaluate and establish the use of required personal protective equipment such as gloves, on or about 03/18/2015. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100138 A |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
50 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes: a. At the pallet refurbishing area, employees were exposed to cuts, lacerations, abrasions and puncture wounds while handling pallets during refurbishing which had protruding nails, splinters and broken wooden parts, on or about 03/18/2015. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-24 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
50 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. At the site, employees were exposed to the hazard of inadvertent energization or release of stored energy during maintenance operations on equipment such as, but not limited to, pallet refurbishing saws, a notcher, a bailer, transfer conveyor systems which were operated using electrical power, compressed air and hydraulic power. Equipment specific lockout/tagout procedures were not developed and implemented to include at a minimum the following: 1. A specific statement of the intended use of the procedure. 2. Specific procedural steps for shutting down, isolating, blocking, and securing machines or equipment to control hazardous energy. 3. Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. 4. Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices and other energy control measures. 5. The magnitude of hazardous energy. on or about 03/18/2015. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100176 B |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a. At the maintenance shop, employees were exposed to a struck by hazard, in that, old saw blades were stacked 6 feet high without being secured from sliding or collapse, on or about 03/18/2015. |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19100178 L02 III |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-17 |
Current Penalty |
2100.0 |
Initial Penalty |
3500.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
50 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(2)(iii): All operator training and evaluation was not conducted by persons who had the knowledge, training, and experience to train powered industrial truck operators and evaluate their performance: a. At the site, employees were required to operate forklifts daily without being trained by a qualified trainer, on or about 03/18/2015. |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19100178 L04 I |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
50 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(i): The powered industrial truck (PITs) operators were not trained and evaluated at least once every three years: a. At the site, employees required to operate forklifts and handle stacks of pallets had not been trained as required, on or about 03/18/2015. |
|
Citation ID |
01007A |
Citaton Type |
Serious |
Standard Cited |
19100178 M06 |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-24 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(m)(6): The employer did not ensure that safe distance was maintained from the edge of ramps or platforms while on any elevated dock, or platform or freight car: a. At the loading dock, employees were exposed to a struck by and a caught in hazard, in that, a safe distance from the loading dock edge was not maintained while operating forklifts. The curb at the west side of the loading dock was knocked off twice and the curb at the east side of the dock was damaged after being hit by the forklifts. No other means were implemented to prevent the forklifts from inadvertently being driven off the dock sides, on or about 03/18/2015. |
|
Citation ID |
01007B |
Citaton Type |
Serious |
Standard Cited |
19100178 M07 |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(m)(7): Brakes were not set and/or wheel blocks were not in place to prevent movement of trucks, trailers, or railroad cars while loading and unloading: a. At the loading dock, employees were exposed to a struck by and a caught in hazard, in that, measures to prevent the displacement of trailers while loading and offloading were not taken while using forklifts to enter tractor trailers, on or about 03/18/2015. |
|
Citation ID |
01008A |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-24 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2015-08-19 |
Nr Instances |
4 |
Nr Exposed |
50 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. Baler area, employees were exposed to a caught in hazard, in that, the front of the baler had a 2 inch opening, on or about 03/18/2015. b. De-stacking area conveyor, employees were exposed to a caught-in hazard, in that, protection was not provided to prevent contact with the live rollers while handling pallets on the conveyor, on or about 03/18/2015. c. Hooker chop saw area, employee were exposed to a caught in hazard, at the "Cutting Machine", in that the left side of the saw's lower portion of the blade was partially exposed, on or about 03/18/2015. d. Stacking area, at the end of the conveyor line, employees were exposed to a caught-in hazard, in that, protection was not provided to prevent contact with the live rollers while handling pallets on the conveyor, on or about 03/18/2015. |
|
Citation ID |
01008B |
Citaton Type |
Serious |
Standard Cited |
19100212 A05 |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
50 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: a. Heat treatment oven, employees were exposed to a struck by hazard, in that, guards were not installed to protect employees from the rotating fan blades used to circulate the air inside the oven after an interlock at the door was broken and disabled, on or about 03/18/2015. |
|
Citation ID |
01008C |
Citaton Type |
Serious |
Standard Cited |
19100213 S06 |
Issuance Date |
2015-07-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
50 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards: a. At the trim saw area, employees were exposed to the point of operation of the saw, in that, the guard was stuck in the up position due to the accumulation of saw dust, on or about 03/18/2015. |
|
Citation ID |
01009 |
Citaton Type |
Serious |
Standard Cited |
19100219 F03 |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2015-08-19 |
Nr Instances |
10 |
Nr Exposed |
50 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: a. De-stacking area, employees were exposed to a caught-in hazard, in that, the chain and sprocket wheel at the hydraulic pump on the de-stacker was not guarded, on or about 03/18/2015. b. De-stacking area, employees were exposed to a caught-in hazard, in that, the chain and sprocket wheel at both sides of the de-stacker were not guarded, on or about 03/18/2015. c. Stacking area at the west side of the de-stacker, employees were exposed to a caught-in hazard, in that, four chains and sprocket wheels used to transfer the pallets at the stacking area were not guarded, on or about 03/18/2015. d. Stacking and de-stacking, employees were exposed to a caught-in hazard, in that, two chains and sprocket wheels used to transfer the pallets at the stacking area were not guarded, on or about 03/18/2015. e. At the end of the refurbishing line, employees were exposed to a caught-in hazard, in that, two stacking conveyors had unguarded chain and sprocket wheels on one side, on or about 03/18/2015. f. At the side of the refurbishing conveyor near the middle and over a repair table, employees were exposed to a caught-in hazard, in that, a chain and sprocket wheel were not guarded, on or about 03/18/2015. g. At the trim saw area, employees were exposed to a caught-in hazard, in that, the chain and sprocket wheels were not guarded on both sides of the saw, on or about 03/18/2015. h. At the Stringer trim saw area, employees were exposed to a caught-in hazard, in that, the chain and sprocket wheel was not guarded at the operator's station, on or about 03/18/2015. |
|
Citation ID |
01010 |
Citaton Type |
Serious |
Standard Cited |
19100242 A |
Issuance Date |
2015-07-29 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
50 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition: a. At the pallet refurbishing areas, employees were exposed to a struck by hazard, in that, the safety feature of the nail guns was bypassed, in that, the spring in the safety contact tip of the nail guns were removed, on or about 03/18/21015. |
|
Citation ID |
01011 |
Citaton Type |
Serious |
Standard Cited |
19100303 B01 |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2015-08-19 |
Nr Instances |
4 |
Nr Exposed |
50 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a. De-stacking area , employees were exposed to an electrical hazard, in that, the wiring providing power to the operating console for the de-stacker and for other equipment had the outer insulation cut and frayed, the conduit was disconnected and broken off at the connections and was cut therefore exposing the individual conductors, on or about 03/18/2015. b. At the un-nailer near the stacker area, employees were exposed to an electrical hazard, in that, the wiring to the hydraulic motor for the un-nailer was exposed and was hanging out of the box, on or about 03/18/2015. c. At the band saw area, employees were exposed to an electrical hazard, in that, the wiring to the motor for the saw was exposed and was hanging out of the box, on or about 03/18/2015. d. Stringer Trim saw area, employees were exposed to an electrical hazard, in that, the two wires from the main power panel to the on/off switch for the saw were frayed and the bare conductors were coming in contact with the saw's frame, on or about 03/18/2015. |
|
Citation ID |
01012 |
Citaton Type |
Serious |
Standard Cited |
19100303 B07 IV |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-24 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2015-08-19 |
Nr Instances |
2 |
Nr Exposed |
50 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: a. Board Trim saw area, employees were exposed to an electrical hazard, in that, the 220 volt fuse electrical box for the saw was equipped with a door that was damaged and would not close exposing the live conductors to getting wet and to employee contact, on or about 03/18/2015. b. At the power panel near the band saws, employees were exposed to an electrical hazard, in that, a metal 4-way outlet box had one of the two outlet components pushed in and bent to the side, on or about 03/18/2105. |
|
Citation ID |
01013 |
Citaton Type |
Serious |
Standard Cited |
19100303 F02 |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
2100.0 |
Initial Penalty |
3500.0 |
Final Order |
2015-08-19 |
Nr Instances |
3 |
Nr Exposed |
50 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a. Refurbishing area, at the main breaker power supply panel area, employees were exposed to an electrical hazard as well as mechanical hazards, in that, the three breaker panels had a total of 31 breakers without a label to indicate their purpose, on or about 03/18/2015. b. At the power panel near the band saws, employees were exposed to an electrical hazard, in that, a breaker panel had a total of 6 breakers without a label to indicate their purpose, on or about 03/18/2015. c. Panel Z, near the compressor room, employees were exposed to an electrical hazard, in that, a breaker panel had a total of 6 breakers without a label to indicate their purpose, on or about 03/18/2015. |
|
Citation ID |
01014 |
Citaton Type |
Serious |
Standard Cited |
19100304 G05 |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-24 |
Current Penalty |
2100.0 |
Initial Penalty |
3500.0 |
Final Order |
2015-08-19 |
Nr Instances |
2 |
Nr Exposed |
50 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. Trim saw area, employees were exposed to an electrical hazard, in that, a red extension cord used in the area had the ground prong broken off, on or about 03/18/2015. b. Stringer trim saw, employees were exposed to an electrical hazard, in that, the wiring to the on/off box had the ground disconnected, on or about 03/18/2015. |
|
Citation ID |
01015 |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 III |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-24 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-08-19 |
Nr Instances |
6 |
Nr Exposed |
50 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a. At the table saw area, employees were exposed to an electrical hazard, in that, the flexible cord providing power to the table saw was not connected with strain relief so that pull in not transmitted to the terminals or screws, on or about 03/18/2015. b. Notcher area, employees were exposed to an electrical hazard, in that, the wiring to the exterior light outside the overhung was spliced with electrical wire caps without strain relief, on or about 03/18/2015. c. Trim saw area, employees were exposed to an electrical hazard, in that, the wiring to the trim saw's on/off switch was not connected with strain relief, on or about 03/18/2015. d. Trim saw area, employees were exposed to an electrical hazard, in that, a red extension cord had the outer sheath pulled from the plug thus transmitting pull on the terminals or screws, on or about 03/18/2015. e. Stringer Trim saw area at the side of the box and to the bottom of the box, employees were exposed to an electrical hazard, in that, the wiring to the saw's on/off switch was not connected with strain relief, on or about 03/18/2015. f. Trash conveyor, employees were exposed to an electrical hazard, in that, the wiring to the conveyor was not connected with strain relief, on or about 03/18/2015. |
|
Citation ID |
01016 |
Citaton Type |
Serious |
Standard Cited |
19100305 J04 II |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
2100.0 |
Initial Penalty |
3500.0 |
Final Order |
2015-08-19 |
Nr Instances |
2 |
Nr Exposed |
50 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(j)(4)(ii): An individual disconnecting means was not provided for each motor, motor circuit and controller: a. At the table saw area, employees were exposed to a struck by hazard while operating the Powermatic table saw, in that, a disconnect was not provided that would electrically isolate and deenergize the saw from its power supply, on or about 03/18/2015. b. At the notcher area, employees were exposed to a struck by hazard while operating the notcher, in that, a disconnect was not provided that would electrically isolate and deenergize the equipment from its power supply, on or about 03/18/2015. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100212 B |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a. At the maintenance shop, employees were exposed to a struck by hazard, in that, a bench top Delta drill press was not anchored as required to prevent it from tipping over or moving when in use, on or about 03/18/2015. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100303 B02 |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
3 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. At the table saw area, employees were exposed to an electrical hazard, in that, power to the Powermatic table saw was provided by splicing the saw's power cord using two outlet boxes which were not secured on a surface as required, on or about 03/18/2015. b. At the refurbishing line, employees were exposed to an electrical hazard, in that, a multi outlet computer power strip was used to provide power to equipment such as floor fans and radios, on or about 03/18/2015. c. At the time clock room, employees were exposed to an electrical hazards, in that, the lighting fixture in the room was not mounted on the ceiling and was allowed to be suspended from the wiring, on or about 03/18/2015. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100304 F01 VIII |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD": a. Refurbishing area main power panels, employees were exposed to an electrical hazard, in that, the breaker used as a switch to control the lighting was not of the SWD type, on or about 03/18/2015. |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100305 B01 II |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
4 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. Refurbishing area, at the main breaker power supply panel area, employees were exposed to an electrical hazard, in that, the power box below the breaker panels had a knockout without a cover, on or about 03/18/2015. b. Baler area, employees were exposed to an electrical hazard, in that, a power box at the side of the baler had a knockout without a cover, on or about 03/18/2015. c. Refurbishing area main breaker panel, employees were exposed to an electrical hazard, in that, a breaker opening was not provided with a cover, on or about 03/18/2015. d. Stringer trim saw area, employees were exposed to an electrical hazard, in that, the electrical box to the saw's power panel had two knockouts without a cover in an area where the equipment was subject to getting wet, on or about 03/18/2015. |
|
Citation ID |
02005 |
Citaton Type |
Other |
Standard Cited |
19100305 B02 I |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a. At the time clock room, employees were exposed to an electrical hazard, in that, an outlet receptacle was not provided with a cover, on or about 03/18/2015. |
|
Citation ID |
02006 |
Citaton Type |
Other |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
2 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. At the time clock room, employees were exposed to an electrical hazard, in that, an extension cord was used in place of fixed wiring and was run through the wall to provide power to the beverage machine located outside the room, on about 03/18/2015. b. Trim saw area, employees were exposed to an electrical hazard, in that, a red extension cord was used in place of fixed wiring to provide power for tools and equipment near the saw, on or about 03/18/2015. |
|
Citation ID |
02007 |
Citaton Type |
Other |
Standard Cited |
19100305 G01 IV B |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
2 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(B): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used when run through holes in walls, ceilings, or floors: a. Compressor area, employees were exposed to an electrical hazard, in that, the wiring to the compressor air tank water separator was passed through a hole on the metal exterior maintenance shop wall, on or about 03/18/2015. b. At the time clock room, employees were exposed to an electrical hazard, in that, an extension cord was run through the wall to provide power to the beverage machine located outside the room, on about 03/18/2015. |
|
Citation ID |
02008 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 II |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
3 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: a. Compressor area, employees were exposed to an electrical hazard, in that, the wiring to the compressor air tank water separator was spliced with electrical tape and wire caps, on or about 03/18/2015. b. Notcher area, employees were exposed to an electrical hazard, in that, the wiring to the exterior light outside the overhang was spliced with electrical wire caps, on or about 03/18/2015. c. At the catwalk after the de-stacking area, employees were exposed to an electrical hazard, in that, the wiring to the light mounted around the catwalk was spliced with electrical wire caps only, on or about 03/18/2015. |
|
Citation ID |
02009 |
Citaton Type |
Other |
Standard Cited |
19100305 J02 VII |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
2 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(j)(2)(vii): A receptacle installed in a wet location where the product intended to be plugged into it was to be attended while in use (for example, portable tools) did not have an enclosure that was weatherproof when the attachment plug cap was removed: a. Refurbishing area, at the main breaker power supply panel area, employees were exposed to an electrical hazard, in that, a 4-way outlet box installed below the power panels which was subject to getting wet did not have a cover, on or about 03/18/2015. b. Pallet repair tables at the east side of the refurbishing area, employees were exposed to an electrical hazard, in that, a 2-way outlet box installed at the exterior wall of the building which was subject to getting wet did not have a cover, on or about 03/18/2015. |
|
Citation ID |
02010 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. At the site, employees were exposed to chemicals such as, but not limited to, compressed gases (oxygen, acetylene and propane), mineral spirits, shop supplies such as WD-40 and spray paint, PVC glue and primer and various types of oils. A written hazard communication program was not developed and implemented as required, on or about 03/18/2015. |
|
Citation ID |
02011 |
Citaton Type |
Other |
Standard Cited |
19101200 G08 |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required safety data sheets for each hazardous chemical in the workplace: a. At the site, employees were exposed to chemicals such as, but not limited to, compressed gases (oxygen, acetylene, propane), mineral spirits, shop supplies and spray paint, PVC glue and primer and various types of oils, on or about 03/18/2015. |
|
Citation ID |
02012 |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2015-07-29 |
Abatement Due Date |
2015-08-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-19 |
Nr Instances |
1 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. On site, employees were exposed to chemicals such as, but not limited to, compressed gases oxygen, acetylene, propane, mineral spirits, shop supplies and spray paint, PVC glue and primer and various types of oils. The employees were not provided training and education on the hazardous chemicals at the workplace, on or about 03/18/2015. |
|
|