Entity Name: | INVACARE CORPORATION |
Jurisdiction: | FLORIDA |
Filing Type: | Foreign Profit |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 14 Jan 1994 (31 years ago) |
Last Event: | CORPORATE MERGER |
Event Date Filed: | 28 Aug 2001 (24 years ago) |
Document Number: | F94000000218 |
FEI/EIN Number |
95-2680965
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | One Invacare Way, Elyria, OH, 44035, US |
Mail Address: | One Invacare Way, Elyria, OH, 44035, US |
Place of Formation: | OHIO |
Name | Role | Address |
---|---|---|
C T CORPORATION SYSTEM | Agent | - |
LaPlaca Anthony C | Seni | One Invacare Way, Elyria, OH, 44035 |
Zhu Kai P | Seni | One Invacare Way, Elyria, OH, 44035 |
Purtill Geoff P | President | One Invacare Way, Elyria, OH, 44035 |
Purtill Geoff P | Director | One Invacare Way, Elyria, OH, 44035 |
LaPlaca Anthony C | Director | One Invacare Way, Elyria, OH, 44035 |
Zhu Kai | Director | One Invacare Way, Elyria, OH, 44035 |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G17000127777 | TOP END | ACTIVE | 2017-11-21 | 2027-12-31 | - | ONE INVACARE WAY, LEGAL DEPARTMENT, ELYRIA, OH, 44035 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2024-04-10 | One Invacare Way, Elyria, OH 44035 | - |
CHANGE OF MAILING ADDRESS | 2024-04-10 | One Invacare Way, Elyria, OH 44035 | - |
MERGER | 2001-08-28 | - | CORPORATION WAS A MERGER RESULT. TOTAL NUMBER OF QUALIFIED CORPORATION(S) INVOLVED WAS 1. MERGER NUMBER 300000038313 |
REGISTERED AGENT NAME CHANGED | 1999-08-05 | C T CORPORATION SYSTEM | - |
REGISTERED AGENT ADDRESS CHANGED | 1999-08-05 | 1200 SOUTH PINE ISLAND ROAD, PLANTATION, FL 33324 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-10 |
ANNUAL REPORT | 2023-02-27 |
ANNUAL REPORT | 2022-03-30 |
ANNUAL REPORT | 2021-04-24 |
ANNUAL REPORT | 2020-05-28 |
ANNUAL REPORT | 2019-03-19 |
ANNUAL REPORT | 2018-04-04 |
ANNUAL REPORT | 2017-04-15 |
ANNUAL REPORT | 2016-04-02 |
ANNUAL REPORT | 2015-04-15 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343268421 | 0420600 | 2018-06-20 | 2101 E. LAKE MARY BLVD., SANFORD, FL, 32773 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1347703 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2018-09-12 |
Current Penalty | 3957.6 |
Initial Penalty | 6596.0 |
Final Order | 2018-10-10 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: (a) At the IVC Assembly J-Box area - the two finger control box was 3 inches from the point of operation, exposing employees to a crushing hazard, on or about June 12, 2018. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2017-02-27 |
Emphasis | L: FORKLIFT, N: AMPUTATE |
Case Closed | 2017-05-18 |
Related Activity
Type | Referral |
Activity Nr | 1184458 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19100037 B06 |
Issuance Date | 2017-04-26 |
Current Penalty | 0.0 |
Initial Penalty | 5541.0 |
Final Order | 2017-05-16 |
Nr Instances | 1 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.37(b)(6): Each exit sign must be illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. Self-luminous or electroluminescent signs that have a minimum luminance surface value of at least .06 footlamberts (0.21 cd/m2) are permitted. In the Production Area - the exit sign over the north front door was not illuminated for employees working in the production area, on or about 2/17/2017 |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2017-04-26 |
Current Penalty | 6926.0 |
Initial Penalty | 6926.0 |
Final Order | 2017-05-16 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: (a) In the production area, there was over no guard on the pinch roller machine exposing employees to a caught in hazard, on or about 2/17ex/2017. |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Health |
Close Conference | 2013-02-05 |
Emphasis | L: EISAX, L: EISAOF |
Case Closed | 2013-05-22 |
Related Activity
Type | Complaint |
Activity Nr | 778791 |
Safety | Yes |
Health | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100252 B03 |
Issuance Date | 2013-04-11 |
Abatement Due Date | 2013-05-07 |
Current Penalty | 1530.0 |
Initial Penalty | 2550.0 |
Final Order | 2013-04-24 |
Nr Instances | 1 |
Nr Exposed | 27 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.252(b)(3): Employees exposed to the hazards created by welding, cutting, or brazing operations were not protected by personal protective equipment in accordance with the requirements of 29 CFR 1910.132: a) for employees fabricating wheelchair parts at the welding shop located at 4501 63rd Circle North Pinellas Park (FL), as observed on or about 3/13/2013. Employees were observed welding without the use of welding jackets or sleeves to protect their exposed skin from burns and harmful UV rays. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100132 D01 |
Issuance Date | 2013-04-11 |
Abatement Due Date | 2013-05-07 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-04-24 |
Nr Instances | 1 |
Nr Exposed | 27 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): a) for employees fabricating wheelchairs parts at the welding shop located at 4501 63rd Circle North Pinellas Park (FL) as observed on or about 3/13/2013. In that the employer's assessment did not require employees to use welding jackets or sleeves to protect their exposed skin from burns and harmful UV rays. |