Entity Name: | GIBRALTAR CONSTRUCTION COMPANY, INC. |
Jurisdiction: | FLORIDA |
Filing Type: | Foreign Profit |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 03 Feb 1993 (32 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 22 Apr 2002 (23 years ago) |
Document Number: | F93000000814 |
FEI/EIN Number |
520982154
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 42 HUDSON ST., STE. 107, ANNAPOLIS, MD, 21401 |
Mail Address: | 42 HUDSON ST., STE. 107, ANNAPOLIS, MD, 21401 |
Place of Formation: | MARYLAND |
Name | Role | Address |
---|---|---|
REGISTERED AGENTS LEGAL SERVICES, INC. | Agent | - |
BERNHARDT PHILLIP | Chief Executive Officer | 304 LOCUST THORN COURT, MILLERSVILLE, MD, 21108 |
FORMAN STEVEN | Vice President | 202 ROCK RIDGE ROAD, MILLERSVILLE, MD, 21108 |
GARRIS SHIRLEY | Secretary | 42 HUDSON ST., ANNAPOLIS, MD, 21401 |
MITCHELL MATTHEW T | President | 206 Holland Road, Severna Park, MD, 21146 |
Gordy Roxanne | Secretary | 42 HUDSON ST, ANNAPOLIS, MD, 21401 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT ADDRESS CHANGED | 2006-11-09 | 155 OFFICE PLAZA DR., SUITE A, TALLAHASSEE, FL 32301 | - |
REINSTATEMENT | 2002-04-22 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2002-04-22 | 42 HUDSON ST., STE. 107, ANNAPOLIS, MD 21401 | - |
CHANGE OF MAILING ADDRESS | 2002-04-22 | 42 HUDSON ST., STE. 107, ANNAPOLIS, MD 21401 | - |
REGISTERED AGENT NAME CHANGED | 2002-04-22 | REGISTERED AGENTS LEGAL SERVICES, INC. | - |
REVOKED FOR ANNUAL REPORT | 1996-08-23 | - | - |
Document Number | Status | Case Number | Name of Court | Date of Entry | Expiration Date | Amount Due | Plaintiff |
---|---|---|---|---|---|---|---|
J13000300468 | TERMINATED | 1000000395284 | LEON | 2013-01-29 | 2033-02-06 | $ 330.00 | STATE OF FLORIDA, DEPARTMENT OF REVENUE, OUT OF STATE COLLECTIONS UNIT, 1401 W US HIGHWAY 90 STE 100, LAKE CITY FL320556123 |
Name | Date |
---|---|
ANNUAL REPORT | 2024-01-25 |
ANNUAL REPORT | 2023-02-14 |
ANNUAL REPORT | 2022-04-04 |
ANNUAL REPORT | 2021-03-17 |
ANNUAL REPORT | 2020-02-18 |
ANNUAL REPORT | 2019-03-15 |
ANNUAL REPORT | 2018-02-28 |
ANNUAL REPORT | 2017-02-15 |
ANNUAL REPORT | 2016-03-02 |
ANNUAL REPORT | 2015-01-21 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345128888 | 0420600 | 2021-02-02 | 10750 ULMERTON RD PINELLAS COUNTY SHERIFF'S OFFICE, LARGO, FL, 33778 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1512886 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2021-04-09 |
Current Penalty | 5250.0 |
Initial Penalty | 6827.0 |
Final Order | 2021-05-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1):Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about 2/2/2021, near the entrance of the Sheriff's office, employees were not protected from falling 11 feet while installing tarps on scaffolding being used to create a wind-debris barrier. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260451 F03 |
Issuance Date | 2021-04-09 |
Current Penalty | 0.0 |
Initial Penalty | 6827.0 |
Final Order | 2021-05-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(f)(3):Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a. On or about 2/2/2021, near the entrance of the Sheriff's office, two employees were directed to secure tarps that were acting as a wind-debris barrier along a walkway that was enclosed by scaffolding. The scaffolding had not been inspected by a competent person before the start of the workday and the scaffold did not have guardrails installed or a safe means of access, thus exposing the employee to a 11 foot fall hazard. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2021-04-09 |
Abatement Due Date | 2021-05-05 |
Current Penalty | 0.0 |
Initial Penalty | 6827.0 |
Final Order | 2021-05-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a):The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a. On or about 2/2/2021, near the entrance of the Sheriff's office, employees were directed to secure tarps that were acting as a wind barrier along a walkway that was enclosed by scaffolding. The exposed employees had not been trained on the hazards of working on and from scaffolding and were not protected from falling 11 feet to ground below. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2021-04-09 |
Current Penalty | 5250.0 |
Initial Penalty | 6827.0 |
Final Order | 2021-05-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: a. On or about 2/2/2021, near the entrance of the Sheriff's office, employees used a portable 10-foot platform ladder to access the top of level of scaffolding, which measured 10 feet 7 inches high itself. The ladder was not secured in place and the employees were not provided a safe method of mounting and dismounting the ladder. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19261060 A01 |
Issuance Date | 2021-04-09 |
Abatement Due Date | 2021-05-05 |
Current Penalty | 0.0 |
Initial Penalty | 6827.0 |
Final Order | 2021-05-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1060(a)(1):The employer did not provide a training program for each employee using ladders as necessary, enabling each employee to recognize hazards related to ladders and the procedures to be followed to minimize these hazards: a. On or about 2/2/2021, near the entrance of the Sheriff's office, untrained employees used a portable 10-foot platform ladder to access the top of scaffolding that measured 10 feet 7 inches high, thus exposing the employees to a fall hazard. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19040040 A |
Issuance Date | 2021-04-09 |
Abatement Due Date | 2021-04-15 |
Current Penalty | 0.0 |
Initial Penalty | 1366.0 |
Final Order | 2021-05-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1904.40(a):The employer did not provide an authorized government representative the records within the four business hours: a. On or about 2/2/2021, at the jobsite, the employer failed to provide the OSHA 300 and 300A's for the years 2018 through 2021. |