Search icon

J.L.M. MACHINE COMPANY, INC. - Florida Company Profile

Company Details

Entity Name: J.L.M. MACHINE COMPANY, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

J.L.M. MACHINE COMPANY, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 19 Apr 1982 (43 years ago)
Last Event: NAME CHANGE AMENDMENT
Event Date Filed: 09 Jul 1982 (43 years ago)
Document Number: F76735
FEI/EIN Number 592209234

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2704-29TH AVE., E., BRADENTON, FL, 34208
Mail Address: 2704-29TH AVE., E., BRADENTON, FL, 34208
ZIP code: 34208
County: Manatee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
Curls Natasha K Chief Operating Officer 2704-29TH AVE., E., BRADENTON, FL, 34208
GRAHAM KELLEY B Agent 2704-29TH AVE., E., BRADENTON, FL, 34208
GRAHAM, KELLEY B President 2704-29TH AVE., E., BRADENTON, FL, 34208

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2000-06-05 2704-29TH AVE., E., BRADENTON, FL 34208 -
REGISTERED AGENT NAME CHANGED 1999-03-03 GRAHAM, KELLEY B -
CHANGE OF PRINCIPAL ADDRESS 1988-03-04 2704-29TH AVE., E., BRADENTON, FL 34208 -
CHANGE OF MAILING ADDRESS 1988-03-04 2704-29TH AVE., E., BRADENTON, FL 34208 -
NAME CHANGE AMENDMENT 1982-07-09 J.L.M. MACHINE COMPANY, INC. -

Documents

Name Date
ANNUAL REPORT 2024-03-06
ANNUAL REPORT 2023-03-20
ANNUAL REPORT 2022-02-08
ANNUAL REPORT 2021-04-02
ANNUAL REPORT 2020-01-15
ANNUAL REPORT 2019-01-28
ANNUAL REPORT 2018-03-07
ANNUAL REPORT 2017-01-19
ANNUAL REPORT 2016-01-22
ANNUAL REPORT 2015-04-06

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344567441 0420600 2020-01-13 2704-29TH AVENUE EAST, BRADENTON, FL, 34208
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2020-03-23
Emphasis L: HINOISE, N: AMPUTATE
Case Closed 2021-08-11

Related Activity

Type Complaint
Activity Nr 1531461
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2020-05-11
Abatement Due Date 2020-07-31
Current Penalty 1735.2
Initial Penalty 2892.0
Final Order 2020-06-11
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, employees were exposed to the hazards of being struck-by fragments of Thermoplastic Polyvinyl Chloride (PVC) plastic pipe in the event of rupture. a) On or about January 13, 2020, at the machine shop, PVC plastic piping was used in exposed above ground locations to transport compressed air at 80 psi for the operation of air operated machines and tools, exposing employees to struck-by hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100022 A01
Issuance Date 2020-05-11
Abatement Due Date 2020-06-26
Current Penalty 1041.0
Initial Penalty 1735.0
Final Order 2020-06-11
Nr Instances 1
Nr Exposed 8
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition. a) On or about January 13, 2020, at the machine shop, the employer did not keep the shop floor orderly, in that flexible cord was used as a substitute for the fixed wiring, exposing employees to trip and fall hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 2020-05-11
Abatement Due Date 2020-06-26
Current Penalty 1735.2
Initial Penalty 2892.0
Final Order 2020-06-11
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about January 13, 2020, at the machine shop, the employer had no established a program consisting of energy control procedures, employee training and inspections to ensure the startup or release of stored energy could not occur while servicing or maintenance on machinery such as, but not limited to; bandsaws, milling and lathe CNC machines among other equipment with potential to store energy, exposing employees to caught-in, struck-by and electrical hazards.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2020-05-11
Abatement Due Date 2020-06-26
Current Penalty 1735.2
Initial Penalty 2892.0
Final Order 2020-06-11
Nr Instances 9
Nr Exposed 8
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about January 13, 2020, at the machine shop, the DAKE metal cutting horizontal band saw - Model SE912 was missing the motor pulley cover, exposing employees to struck-by hazards created by rotating parts and ingoing nip points. b) On or about January 13, 2020, at the machine shop, the enclosure of the HAAS tool room mill (CNC)  Model TM1 was inadequate, in that, the enclosure design allowed access to the point of operation and other rotating parts from the top and sides, while it was not equipped with safeguarding devices such as presence sensing device. In addition, there was no hazard awareness devices around the table, exposing employees to struck-by and crush-by hazards created by the point of operation, moving table and rotating parts. c) On or about January 13, 2020, at the machine shop, the enclosure of the Mori-Seiki FM2 Vertical Machining Center was not equipped with safeguarding devices such as presence sensing device, exposing employees to stuck-by hazards created by the point of operation and rotating parts. d) On or about January 13, 2020, at the machine shop, the enclosure of the Tsugami BE20-V was not equipped with safeguarding devices such as presence sensing device, exposing employees to stuck-by hazards created by the point of operation and rotating parts. e) On or about January 13, 2020, at the machine shop, the enclosure of the Mori Seiki SL-2HS  2416 (MV Junior X/Y/Z axis) was inadequate, in that, the enclosure design allowed access to the point of operation and other rotating parts from the top and sides, while it was not equipped with safeguarding devices such as presence sensing device. In addition there was no awareness device around the table, exposing employees to struck-by and crush-by hazards created by the point of operation, moving table and rotating parts. f) On or about January 13, 2020, at the machine shop, the enclosure of the FADAL VMC-4020 CNC-88HS was not equipped with safeguarding devices such as presence sensing device, exposing employees to stuck-by hazards created by the point of operation and rotating parts. g) On or about January 13, 2020, at the machine shop, the enclosure of the MORI SEIKI NL 1500 CNC Lathe was not equipped with safeguarding devices such as presence sensing device, exposing employees to stuck-by hazards created by the point of operation and rotating parts. h) On or about January 13, 2020, at the machine shop, the enclosure of the MORI SEIKI CL-150 CNC Lathe was not equipped with safeguarding devices such as presence sensing device, exposing employees to stuck-by hazards created by the point of operation and rotating parts.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2020-05-11
Abatement Due Date 2020-06-26
Current Penalty 1735.2
Initial Penalty 2892.0
Final Order 2020-06-11
Nr Instances 1
Nr Exposed 8
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: a) On or about January 13, 2020, at the machine shop, employees were exposed to struck-by hazard when operating machines such as the Bridgeport J head milling machine (S/N: J-121067), Roll-In band saw EF1459 and SHARP 2050 Heavy Duty Metal Lathe (Model-1250), without a point of operation guard.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100215 A02
Issuance Date 2020-05-11
Abatement Due Date 2020-06-26
Current Penalty 1735.2
Initial Penalty 2892.0
Final Order 2020-06-11
Nr Instances 1
Nr Exposed 8
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: a) On or about February 26, 2020, at the machine shop, the employer does not ensure that grinding machinery such as Craftsman 6-inch and Task Force bench grinders were provided with safety guard(s) which covered the spindle end, nut, and flange, exposing employees to a struck-by hazard.
Citation ID 01007
Citaton Type Serious
Standard Cited 19100242 B
Issuance Date 2020-05-11
Abatement Due Date 2020-06-26
Current Penalty 1735.2
Initial Penalty 2892.0
Final Order 2020-06-11
Nr Instances 9
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about January 13, 2020, at the machine shop, compressed air lines used for cleaning parts and equipment were not reduced to less than 30 PSI, such as but not limited to the compressed air line at the Mori-Seiki FM2 Vertical Machining Center, which had a pressure per square inch of 80.
Citation ID 01008
Citaton Type Serious
Standard Cited 19100305 B02 I
Issuance Date 2020-05-11
Current Penalty 1735.2
Initial Penalty 2892.0
Final Order 2020-06-11
Nr Instances 2
Nr Exposed 8
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) On or about January 13, 2020, at the break area of the machine shop, employees were exposed to an electrical shock hazard, in that the 3-phase, 480-V electrical panel located on the west side wall did not have a faceplate cover. b) On or about January 13, 2020, at the break area of the machine shop, employees were exposed to an electrical hazard, in that the junction box located on the west side wall had no cover.
Citation ID 01009
Citaton Type Serious
Standard Cited 19100334 A02 I
Issuance Date 2020-05-11
Abatement Due Date 2020-06-26
Current Penalty 1387.8
Initial Penalty 2313.0
Final Order 2020-06-11
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) On or about January 13, 2020, at the machine shop, the employer failed to ensure that flexible cords were inspected before use for external defects. In that, the flexible cord used as a substitute for the fixed wiring of a DAKE Horizontal Band Saw (110V) had external signs of overheating.
Citation ID 01010A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2020-05-11
Abatement Due Date 2020-06-26
Current Penalty 1041.0
Initial Penalty 1735.0
Final Order 2020-06-11
Nr Instances 1
Nr Exposed 8
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On January 13, 2020, at the machine shop, the employer did not develop, implement, and/or maintain at the workplace a written hazard communication program for employees handling hazardous materials such as but not limited to acetone, muriatic acid, thinner and Xylol among others, exposing employees to health hazards.
Citation ID 01010B
Citaton Type Serious
Standard Cited 19101200 F06 II
Issuance Date 2020-05-11
Abatement Due Date 2020-06-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-11
Nr Instances 1
Nr Exposed 8
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(f)(6)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals: a) On February 26, 2020, at the east side of the machine shop, the employer did not ensure that two secondary containers of chemicals used by employees were labeled or marked with a product identifier and words, pictures, symbols, or combination thereof with general information about the hazards of the chemical. One container had no identification what so ever while the other had only the words CLEANER and CL-150.
Citation ID 01010C
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2020-05-11
Abatement Due Date 2020-06-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-11
Nr Instances 1
Nr Exposed 8
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) On January 13, 2020, at the machine shop, the employer had not trained employees on the hazards of the chemicals they used, such as but not limited to acetone, muriatic acid, thinner and Xylol, among others, exposing employees to health hazards.
Citation ID 02001
Citaton Type Other
Standard Cited 19100036 D01
Issuance Date 2020-05-11
Abatement Due Date 2020-06-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-11
Nr Instances 1
Nr Exposed 8
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) On or about January 13, 2020, at the machine shop, the south-west and north emergency exit doors were observed to be locked from the inside with doorknob locks.
Citation ID 02002
Citaton Type Other
Standard Cited 19100037 A03
Issuance Date 2020-05-11
Abatement Due Date 2020-06-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-11
Nr Instances 1
Nr Exposed 8
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) On or about January 13, 2020, at the machine shop, the south-west emergency exit route was obstructed by lawncare machines, tools and products, preventing prompt access to the emergency exit door.
Citation ID 02003
Citaton Type Other
Standard Cited 19100305 G01 IV A
Issuance Date 2020-05-11
Abatement Due Date 2020-06-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-06-11
Nr Instances 1
Nr Exposed 8
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure; a) On or about January 13, 2020, at the machine shop, employees were exposed to an electrical hazard, in that, a flexible cord was used as a substitute for the fixed wiring of a DAKE Horizontal Band Saw (110V).