Search icon

DIXON INDUSTRIAL GROUP, (INC.) - Florida Company Profile

Company Details

Entity Name: DIXON INDUSTRIAL GROUP, (INC.)
Jurisdiction: FLORIDA
Filing Type: Foreign Profit
Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 13 Apr 2021 (4 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 18 Nov 2024 (5 months ago)
Document Number: F21000002024
FEI/EIN Number 843567208

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 7891 US HWY 84, PATTERSON, GA, 31557, US
Mail Address: 7891 US HWY 84, PATTERSON, GA, 31557, US
Place of Formation: GEORGIA

Key Officers & Management

Name Role Address
DIXON ROBERT L President 7891 HWY 84, PATTERSON, GA, 31557
DIXON FOSTER L Vice President 7891 HWY 84, PATTERSON, GA, 31557
DIXON KATHRYN Secretary 7891 HWY 84, PATTERSON, GA, 31557
DIXON BRENDA Treasurer 7891 HWY 84, PATTERSON, GA, 31557
API PROCESSING - LICENSING, INC. Agent -

Events

Event Type Filed Date Value Description
REINSTATEMENT 2024-11-18 - -
REGISTERED AGENT NAME CHANGED 2024-11-18 API PROCESSING - LICENSING INC -
REVOKED FOR ANNUAL REPORT 2024-09-27 - -

Documents

Name Date
ANNUAL REPORT 2025-01-30
REINSTATEMENT 2024-11-18
ANNUAL REPORT 2023-02-03
ANNUAL REPORT 2022-03-02
Foreign Profit 2021-04-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347373326 0419700 2024-03-27 1915 WIGMORE STREET, JACKSONVILLE, FL, 32206
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2024-03-27
Emphasis N: CHROME6
Case Closed 2024-09-18

Related Activity

Type Complaint
Activity Nr 2143193
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2024-08-13
Abatement Due Date 2024-09-30
Current Penalty 2350.0
Initial Penalty 2350.0
Final Order 2024-09-12
Nr Instances 1
Nr Exposed 12
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer: a. Production area: On or about March 27, 2024, and times prior, the employer exposed employees to respiratory hazards, in that employees were required to wear respirators while welding or fixing conveyor belts, but the employer failed to establish and implement a written respiratory protection program with worksite-specific procedures.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2024-08-13
Abatement Due Date 2024-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-12
Nr Instances 1
Nr Exposed 12
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. Production area: On or about March 27, 2024, and times prior, the employer exposed employees to respiratory hazards, in that the employer required the use of a respirator by employees without first providing a medical evaluation to determine if the employees were able to wear a respirator or not.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100134 F01
Issuance Date 2024-08-13
Abatement Due Date 2024-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-12
Nr Instances 1
Nr Exposed 12
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a. Production area: On or about March 27, 2024, and times prior, the employer exposed employees to respiratory hazards, in that employees were required to wear a tight-fitting half-face respirator without first being fit tested.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100134 K03
Issuance Date 2024-08-13
Abatement Due Date 2024-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-12
Nr Instances 1
Nr Exposed 12
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: a. Production area: On or about March 27, 2024, and times prior, the employer exposed employees to potential respiratory hazards, in that employees were required to wear a tight-fitting half-face respirator without first being provided training as required by the standard.
Citation ID 02001
Citaton Type Other
Standard Cited 19101026 D01
Issuance Date 2024-08-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-12
Nr Instances 1
Nr Exposed 12
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): a. Welding area: On July 1, 2024 and times prior, the employer did not perform initial exposure monitoring for chromium (VI) for an employee who welded with stainless steel.
Citation ID 02002A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2024-08-13
Abatement Due Date 2024-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-12
Nr Instances 1
Nr Exposed 12
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. Production area: On or about March 27, 2024, the employer exposed employees to hazardous materials such as but not limited to Excalibur 7018, Washington Alloy E7018 and acetone, in that a written hazard communication program was not developed and implemented.
Citation ID 02002B
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2024-08-13
Abatement Due Date 2024-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-12
Nr Instances 1
Nr Exposed 12
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. Production area: On or about March 27, 2024, the employer exposed employees to hazardous materials such as but not limited to Excalibur 7018, Washington Alloy E7018 and acetone without providing effective training on these hazardous materials.