Entity Name: | GORDON FOOD SERVICE, INC. |
Jurisdiction: | FLORIDA |
Filing Type: | Foreign Profit |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 21 Dec 2015 (9 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 01 Oct 2020 (5 years ago) |
Document Number: | F15000005625 |
FEI/EIN Number |
381249848
Federal Employer Identification (FEI) Number assigned by the IRS. |
Mail Address: | PO BOX 2992, GRAND RAPIDS, MI, 49501, US |
Address: | 1300 GEZON PARKWAY SW, WYOMING, MI, 49509, US |
Place of Formation: | MICHIGAN |
Name | Role | Address |
---|---|---|
GORDON DANIEL A | Chairman | 1300 GEZON PARKWAY SW, WYOMING, MI, 49509 |
GORDON JAMES D | Vice Chairman | 1300 GEZON PARKWAY SW, WYOMING, MI, 49509 |
Wolowski Richard J | President | 1300 GEZON PARKWAY SW, WYOMING, MI, 49509 |
SCHMIDT TRACY G | Director | 1300 GEZON PARKWAY SW, WYOMING, MI, 49509 |
GEIER FRANK J | Director | 1300 GEZON PARKWAY SW, WYOMING, MI, 49509 |
Cieslak Alisha A | Secretary | 1300 Gezon Parkway SW, Wyoming, MI, 49509 |
CORPORATION SERVICE COMPANY | Agent | - |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G22000115437 | MEASUR'D | ACTIVE | 2022-09-14 | 2027-12-31 | - | 1300 GEZON PARKWAY SW, WYOMING, MI, 49509 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF MAILING ADDRESS | 2022-04-27 | 1300 GEZON PARKWAY SW, WYOMING, MI 49509 | - |
REINSTATEMENT | 2020-10-01 | - | - |
REGISTERED AGENT NAME CHANGED | 2020-10-01 | CORPORATION SERVICE COMPANY | - |
REVOKED FOR ANNUAL REPORT | 2020-09-25 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2025-01-08 |
ANNUAL REPORT | 2024-01-31 |
ANNUAL REPORT | 2023-04-26 |
ANNUAL REPORT | 2022-04-27 |
ANNUAL REPORT | 2021-04-27 |
REINSTATEMENT | 2020-10-01 |
ANNUAL REPORT | 2019-03-28 |
ANNUAL REPORT | 2018-01-18 |
ANNUAL REPORT | 2017-02-15 |
Foreign Profit | 2015-12-21 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347938979 | 0419730 | 2024-12-17 | FL | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
344346739 | 0420600 | 2019-09-25 | 1410 GORDON FOOD SERVICE DRIVE, PLANT CITY, FL, 33563 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19100025 C01 |
Issuance Date | 2020-03-13 |
Abatement Due Date | 2020-05-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2020-04-01 |
Nr Instances | 1 |
Nr Exposed | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.25(c)(1): The employer did not ensure that standard stairs were installed at angles between 30 to 50 degrees from the horizontal: a. On or about 09/25/2019, at the compressor room, employees were exposed to fall hazards, in that, a stairway leading to the roof had an angle of 60.3 degrees to the horizontal. |
Citation ID | 01002 |
Citaton Type | Other |
Standard Cited | 19100119 D03 II |
Issuance Date | 2020-03-13 |
Abatement Due Date | 2020-05-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2020-04-01 |
Nr Instances | 1 |
Nr Exposed | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices. a. On or about 09/25/2019, at the compressor room, employees were exposed to ammonia, in that, a determination was not made to assure that the exhaust ventilation system in the compressor room was in compliance with recognized and generally accepted good engineering practices after a change was made to the machine room by adding two compressors and a machine room tool vestibule which was separated from the machine room by a wall with an opening of 12 feet high by 22 feet long. |
Citation ID | 01003 |
Citaton Type | Other |
Standard Cited | 19100119 J04 II |
Issuance Date | 2020-03-13 |
Abatement Due Date | 2020-04-29 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2020-04-01 |
Nr Instances | 1 |
Nr Exposed | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.119(j)(4)(ii): Inspections and testing procedures performed on process equipment to maintain its mechanical integrity did not follow recognized and generally accepted good engineering practices (RAGAGEP): a. On or about 9/25/2019, at the ammonia refrigeration process, employees were exposed to ammonia, in that, a corrosion under insulation program was not developed and implemented for insulated equipment and piping. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2018-04-04 |
Emphasis | L: FORKLIFT |
Case Closed | 2018-04-05 |
Related Activity
Type | Referral |
Activity Nr | 1320133 |
Safety | Yes |