Search icon

VERSA INTEGRITY GROUP, INC. - Florida Company Profile

Company Details

Entity Name: VERSA INTEGRITY GROUP, INC.
Jurisdiction: FLORIDA
Filing Type: Foreign Profit
Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 10 Aug 2015 (10 years ago)
Last Event: CORPORATE MERGER
Event Date Filed: 19 Jul 2017 (8 years ago)
Document Number: F15000003513
FEI/EIN Number 46-1617493

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 30 Main Street, Suite 402, Danbury, CT, 06810, US
Mail Address: 30 Main Street, Suite 402, Danbury, CT, 06810, US
Place of Formation: DELAWARE

Key Officers & Management

Name Role Address
Grigsby Michael Director 14434 Medical Complex Drive, Tomball, TX, 77377
Sutherland Fiona E Director Room 260, 2301 Premier Way, Sherwood Park, AB, T8H 28
Pizzey Talman Director Room 260, 2301 Premier Way, Sherwood Park, AB, T8H 28
Palmieri-Lafferty Gina Asst 30 Main Street, Danbury, CT, 06810
CORPORATION SERVICE COMPANY Agent -

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G22000147422 ACUREN INSPECTION INC ACTIVE 2022-12-01 2027-12-31 - 4301 HWY 27 SOUTH, SULPHUR, LA, 70665
G20000163577 VERSA INTEGRITY GROUP OF MOUNTAIN WEST ACTIVE 2020-12-24 2025-12-31 - 1776 YORKTOWN STREET, HOUSTON, TX, 77056

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-04-23 30 Main Street, Suite 402, Danbury, CT 06810 -
CHANGE OF MAILING ADDRESS 2024-04-23 30 Main Street, Suite 402, Danbury, CT 06810 -
MERGER 2017-07-19 - CORPORATION WAS A MERGER RESULT. TOTAL NUMBER OF QUALIFIED CORPORATION(S) INVOLVED WAS 1. MERGER NUMBER 700000173047
REGISTERED AGENT NAME CHANGED 2016-07-01 CORPORATION SERVICE COMPANY -
REGISTERED AGENT ADDRESS CHANGED 2016-07-01 1201 HAYS STREET, TALLAHASSEE, FL 32301 -

Documents

Name Date
ANNUAL REPORT 2024-04-23
ANNUAL REPORT 2023-04-03
AMENDED ANNUAL REPORT 2022-11-04
ANNUAL REPORT 2022-04-26
ANNUAL REPORT 2021-04-21
ANNUAL REPORT 2020-04-28
ANNUAL REPORT 2019-04-18
ANNUAL REPORT 2018-03-09
Merger 2017-07-19
ANNUAL REPORT 2017-02-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342882701 0420600 2018-01-17 COUNTY ROAD 525 AND US HWY 301, SUMTERVILLE, FL, 33585
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2018-01-17
Emphasis N: TRENCH, P: TRENCH
Case Closed 2024-05-29

Related Activity

Type Inspection
Activity Nr 1288278
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260651 H01
Issuance Date 2018-07-10
Current Penalty 0.0
Initial Penalty 5543.0
Contest Date 2018-08-03
Final Order 2020-03-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation: a. At the intersection of US Hwy 301 and County Road 525 in Sumterville Florida, employees were exposed to a caught in hazard, in that, during non-destructive testing of steel piping in a trench with type "C" soil which was 9 feet deep, 22 feet long and 9 feet wide, water was allowed to accumulate while an employee was conducting non-destructive testing, on or about 01/17/2018.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260651 K01
Issuance Date 2018-07-10
Current Penalty 9239.0
Initial Penalty 9239.0
Contest Date 2018-08-03
Final Order 2020-03-02
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 1926.651(k)(1)An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift. a. At the intersection of US Hwy 301 and County Road 525 in Sumterville Florida, on or aboutr 01/17/2018, a competent person did not conduct inspections of an unprotected trench with type "C" soil which was 9 feet deep, 22 feet long and 9 feet wide prior to an employee entering the trench and as needed throughout the shift while an employee was working in the trench.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2018-07-10
Current Penalty 5543.0
Initial Penalty 5543.0
Contest Date 2018-08-03
Final Order 2020-03-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. a. At the intersection of US Hwy 301 and County Road 525 in Sumterville Florida, employees were exposed to a 6.5 foot fall hazard, in that a ladder used to gain access in and out of the trench at the west wall did not extent three feet above the landing surface, on or about 01/17/2018.

Date of last update: 01 Apr 2025

Sources: Florida Department of State