Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-05-18
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2023-01-13
|
Related Activity
Type |
Referral |
Activity Nr |
1894406 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2022-05-23 |
Abatement Due Date |
2022-06-17 |
Current Penalty |
0.0 |
Initial Penalty |
14502.0 |
Contest Date |
2022-06-24 |
Final Order |
2023-01-04 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. On or about May 13, 2022, at the facility, employees were changing-out rotary die cutting boards on a rotary die cutter machine, during which time the employer failed to ensure that an energy control procedure was utilized; therefore, exposing the employees to amputation hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 II |
Issuance Date |
2022-05-23 |
Abatement Due Date |
2022-06-17 |
Current Penalty |
7251.0 |
Initial Penalty |
14502.0 |
Contest Date |
2022-06-24 |
Final Order |
2023-01-04 |
Nr Instances |
2 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: a. On or about May 13, 2022, at the facility, employees were changing-out rotary die cutting boards on a rotary die cutter machine, during which time the energy control procedure (Intermediate Energy State/ IES procedure) did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy; therefore, exposing the employees to amputation hazards. b. On or about May 13, 2022, at the facility, employees were conducting weekly Preventative Maintenance/ PM, such as weekly cleaning of the rotary die cutter machine, during which time the energy control procedure (Zero Energy State/ ZES procedure) did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy; therefore, exposing the employees to amputation hazards. |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19100147 C06 I |
Issuance Date |
2022-05-23 |
Abatement Due Date |
2022-06-17 |
Current Penalty |
14502.0 |
Initial Penalty |
14502.0 |
Contest Date |
2022-06-24 |
Final Order |
2023-01-04 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. On or about May 13, 2022, at the facility, employees were changing-out rotary die cutting boards on a rotary die cutter machine, during which time the employer failed to ensure that a periodic inspection of the energy control procedure had been conducted at least annually to ensure that the procedure and the requirement of this standard were being followed; therefore, exposing the employees to amputation hazards. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2022-05-23 |
Abatement Due Date |
2022-06-17 |
Current Penalty |
14502.0 |
Initial Penalty |
14502.0 |
Contest Date |
2022-06-24 |
Final Order |
2023-01-04 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a. On or about May 13, 2022, at the facility, employees were changing-out rotary die cutting boards on a rotary die cutter machine, during which time Lock-out or Tag-out devices were not affixed by the authorized employees to the energy isolating device for the Die Cut Section of the machine; therefore, exposing the employees to amputation hazards. |
|
|