Search icon

ALRO STEEL CORPORATION - Florida Company Profile

Company Details

Entity Name: ALRO STEEL CORPORATION
Jurisdiction: FLORIDA
Filing Type: Foreign Profit
Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 16 Apr 2012 (13 years ago)
Last Event: CORPORATE MERGER
Event Date Filed: 01 Jul 2020 (5 years ago)
Document Number: F12000001610
FEI/EIN Number 38-1300597

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3100 E. High Street, Jackson, MI, 49203, US
Mail Address: 3100 E. High Street, Jackson, MI, 49203, US
Place of Formation: MICHIGAN

Key Officers & Management

Name Role Address
Pastor Frank Vice President 3100 E. High Street, Jackson, MI, 49203
Rauh James Vice President 3100 E. High Street, Jackson, MI, 49203
Rumler John Vice President 3100 E. High Street, Jackson, MI, 49203
Rumler Todd Vice President 3100 E. High Street, Jackson, MI, 49203
Smith Joe Vice President 3100 E. High Street, Jackson, MI, 49203
Timberlake Mark Vice President 3100 E. High Street, Jackson, MI, 49203
CT Corporation System Agent 1200 South Pine Island Road, Plantation, FL, 33324

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-04-08 3100 E. High Street, Jackson, MI 49203 -
CHANGE OF MAILING ADDRESS 2024-04-08 3100 E. High Street, Jackson, MI 49203 -
REGISTERED AGENT NAME CHANGED 2022-04-28 CT Corporation System -
REGISTERED AGENT ADDRESS CHANGED 2022-04-28 1200 South Pine Island Road, Plantation, FL 33324 -
MERGER 2020-07-01 - CORPORATION WAS A MERGER RESULT. TOTAL NUMBER OF QUALIFIED CORPORATION(S) INVOLVED WAS 1. MERGER NUMBER 700000204567

Documents

Name Date
ANNUAL REPORT 2024-04-08
ANNUAL REPORT 2023-02-25
ANNUAL REPORT 2022-04-28
ANNUAL REPORT 2021-03-20
Merger 2020-07-01
ANNUAL REPORT 2020-04-15
ANNUAL REPORT 2019-04-01
ANNUAL REPORT 2018-04-05
ANNUAL REPORT 2017-04-06
ANNUAL REPORT 2016-04-26

USAspending Awards. Contracts

Contract Type Award or IDV Flag PIID Start Date Current End Date Potential End Date
PURCHASE ORDER AWARD N6883612P1882 2012-07-17 2012-07-27 2012-07-27
Unique Award Key CONT_AWD_N6883612P1882_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 85.80
Current Award Amount 85.80
Potential Award Amount 85.80

Description

Title ALUMINUM BAR
NAICS Code 331312: PRIMARY ALUMINUM PRODUCTION
Product and Service Codes 9510: BARS AND RODS

Recipient Details

Recipient ALRO STEEL CORPORATION
UEI M435DP2XEWG6
Legacy DUNS 063501969
Recipient Address 2505 FORSYTHE RD, ORLANDO, ORANGE, FLORIDA, 328076431, UNITED STATES
PURCHASE ORDER AWARD N6883612P1708 2012-06-26 2012-07-06 2012-07-06
Unique Award Key CONT_AWD_N6883612P1708_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 729.12
Current Award Amount 729.12
Potential Award Amount 729.12

Description

Title ALUMINUM SHEET
NAICS Code 331315: ALUMINUM SHEET, PLATE, AND FOIL MANUFACTURING
Product and Service Codes 9515: PLATE, SHEET, STRIP, FOIL, AND LEAF

Recipient Details

Recipient ALRO STEEL CORPORATION
UEI M435DP2XEWG6
Legacy DUNS 063501969
Recipient Address 2505 FORSYTHE RD, ORLANDO, ORANGE, FLORIDA, 328076431, UNITED STATES
PURCHASE ORDER AWARD N6883612P1637 2012-06-19 2012-07-03 2012-07-03
Unique Award Key CONT_AWD_N6883612P1637_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 189.00
Current Award Amount 189.00
Potential Award Amount 189.00

Description

Title ALUM FLAT BAR
NAICS Code 332999: ALL OTHER MISCELLANEOUS FABRICATED METAL PRODUCT MANUFACTURING
Product and Service Codes 9530: BARS AND RODS, NONFERROUS BASE METAL

Recipient Details

Recipient ALRO STEEL CORPORATION
UEI M435DP2XEWG6
Legacy DUNS 063501969
Recipient Address 2505 FORSYTHE RD, ORLANDO, ORANGE, FLORIDA, 328076431, UNITED STATES
PURCHASE ORDER AWARD N6883612P1304 2012-05-02 2012-05-09 2012-05-09
Unique Award Key CONT_AWD_N6883612P1304_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 1198.55
Current Award Amount 1198.55
Potential Award Amount 1198.55

Description

Title PLATE, ALUMINUM
NAICS Code 332999: ALL OTHER MISCELLANEOUS FABRICATED METAL PRODUCT MANUFACTURING
Product and Service Codes 9535: PLATE, SHEET, STRIP, AND FOIL; NONFERROUS BASE METAL

Recipient Details

Recipient ALRO STEEL CORPORATION
UEI M435DP2XEWG6
Legacy DUNS 063501969
Recipient Address 2505 FORSYTHE RD, ORLANDO, ORANGE, FLORIDA, 328076431, UNITED STATES
PURCHASE ORDER AWARD N6883612P1175 2012-04-17 2012-05-03 2012-05-03
Unique Award Key CONT_AWD_N6883612P1175_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 13286.01
Current Award Amount 13286.01
Potential Award Amount 13286.01

Description

Title SQUARE GA WALL TUBING 2 X 2 X 11
NAICS Code 332999: ALL OTHER MISCELLANEOUS FABRICATED METAL PRODUCT MANUFACTURING
Product and Service Codes 9515: PLATE, SHEET, STRIP, FOIL, AND LEAF

Recipient Details

Recipient ALRO STEEL CORPORATION
UEI M435DP2XEWG6
Legacy DUNS 063501969
Recipient Address 2505 FORSYTHE RD, ORLANDO, ORANGE, FLORIDA, 328076431, UNITED STATES
PURCHASE ORDER AWARD FA282312P8015 2012-03-06 2012-04-06 2012-04-06
Unique Award Key CONT_AWD_FA282312P8015_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 15408.62
Current Award Amount 15408.62
Potential Award Amount 15408.62

Description

Title 4140 STEEL PLATES (24' X 95'), 1045 STEEL PLATES (12-1/8 X 66')
NAICS Code 423510: METAL SERVICE CENTERS AND OTHER METAL MERCHANT WHOLESALERS
Product and Service Codes 9510: BARS AND RODS

Recipient Details

Recipient ALRO STEEL CORPORATION
UEI M435DP2XEWG6
Legacy DUNS 063501969
Recipient Address 2505 FORSYTHE RD, ORLANDO, ORANGE, FLORIDA, 328076431, UNITED STATES
PURCHASE ORDER AWARD N6883611P2544 2011-09-07 2011-09-14 2011-09-14
Unique Award Key CONT_AWD_N6883611P2544_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 273.16
Current Award Amount 273.16
Potential Award Amount 273.16

Description

Title ALUM BAR
NAICS Code 331221: ROLLED STEEL SHAPE MANUFACTURING
Product and Service Codes 9530: BARS & RODS NONFERROUS BASE METAL

Recipient Details

Recipient ALRO STEEL CORPORATION
UEI M435DP2XEWG6
Legacy DUNS 063501969
Recipient Address 2505 FORSYTHE RD, ORLANDO, ORANGE, FLORIDA, 328076431, UNITED STATES
PURCHASE ORDER AWARD N6883611P2180 2011-08-05 2011-08-15 2011-08-15
Unique Award Key CONT_AWD_N6883611P2180_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 206.56
Current Award Amount 206.56
Potential Award Amount 206.56

Description

Title ALUM TUBE
NAICS Code 423510: METAL SERVICE CENTERS AND OTHER METAL MERCHANT WHOLESALERS
Product and Service Codes 9530: BARS & RODS NONFERROUS BASE METAL

Recipient Details

Recipient ALRO STEEL CORPORATION
UEI M435DP2XEWG6
Legacy DUNS 063501969
Recipient Address 2505 FORSYTHE RD, ORLANDO, ORANGE, FLORIDA, 328076431, UNITED STATES
PURCHASE ORDER AWARD N6883611P1353 2011-04-28 2011-05-13 2011-05-13
Unique Award Key CONT_AWD_N6883611P1353_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 797.04
Current Award Amount 797.04
Potential Award Amount 797.04

Description

Title QQ-A-200/8 6061-T6 ALUM TUBE 5" OD X 4"
NAICS Code 331312: PRIMARY ALUMINUM PRODUCTION
Product and Service Codes 9530: BARS & RODS NONFERROUS BASE METAL

Recipient Details

Recipient ALRO STEEL CORPORATION
UEI M435DP2XEWG6
Legacy DUNS 063501969
Recipient Address 2505 FORSYTHE RD, ORLANDO, ORANGE, FLORIDA, 328076431, UNITED STATES
PURCHASE ORDER AWARD N6883611P1279 2011-04-18 2011-04-29 2011-04-29
Unique Award Key CONT_AWD_N6883611P1279_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 1329.35
Current Award Amount 1329.35
Potential Award Amount 1329.35

Description

Title ALUM BAR
NAICS Code 331221: ROLLED STEEL SHAPE MANUFACTURING
Product and Service Codes 9510: BARS AND RODS

Recipient Details

Recipient ALRO STEEL CORPORATION
UEI M435DP2XEWG6
Legacy DUNS 063501969
Recipient Address 2505 FORSYTHE RD, ORLANDO, ORANGE, FLORIDA, 328076431, UNITED STATES

USAspending Awards. Financial Assistance

FAIN Awarding Agency Assistance Listings Start Date End Date Description
09475587ST1002 Export-Import Bank of the United States 31.007 - EXPORT - LOAN GUARANTEE/INSURED LOANS 2011-05-01 2012-05-01 EXPORT INSURANCE COVERED PRODUCTS: INDUSTRIAL SUPPLIES MERCHANT WHOLESALERS
Recipient ALRO STEEL CORP
Recipient Name Raw ALRO METALS SERVICE CENTER CORPORATION
Recipient UEI JS7UCD2CKM75
Recipient DUNS 041182767
Recipient Address 6200 PARK OF COMMERCE BLVD, BOCA RATON, PALM BEACH, FLORIDA, 33487-8201, UNITED STATES
Obligated Amount 950000.00
Non-Federal Funding 0.00
Original Subsidy Cost 0.00
Face Value of Direct Loan 0.00
Link View Page
09475587ST1001 Export-Import Bank of the United States 31.007 - EXPORT - LOAN GUARANTEE/INSURED LOANS 2010-05-01 2011-05-01 EXPORT INSURANCE COVERED PRODUCTS: INDUSTRIAL SUPPLIES MERCHANT WHOLESALERS
Recipient ALRO STEEL CORP
Recipient Name Raw ALRO METALS SERVICE CENTER CORPORATION
Recipient UEI JS7UCD2CKM75
Recipient DUNS 041182767
Recipient Address 6200 PARK OF COMMERCE BLVD, BOCA RATON, PALM BEACH, FLORIDA, 33487-8201, UNITED STATES
Obligated Amount 950000.00
Non-Federal Funding 0.00
Original Subsidy Cost 0.00
Face Value of Direct Loan 0.00
Link View Page

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343626719 0420600 2018-11-28 10223 WOODBERRY RD, TAMPA, FL, 33619
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-11-29
Emphasis L: FORKLIFT
Case Closed 2018-11-29

Related Activity

Type Referral
Activity Nr 1399775
Safety Yes
339668311 0420600 2014-04-09 12490 49TH STREET NORTH, CLEARWATER, FL, 33762
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2014-04-09
Emphasis L: FORKLIFT
Case Closed 2015-03-10

Related Activity

Type Inspection
Activity Nr 877039
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2014-05-13
Abatement Due Date 2014-06-09
Current Penalty 12750.0
Initial Penalty 15000.0
Contest Date 2014-05-13
Final Order 2014-11-10
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: For the Alro Metal Service Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 04/09/2014. Employees operating a horizontal metal band saws were exposed to laceration hazards due to blade guards which did not cover the bottom cutting section of the blade. As observed, an employees' hands could contact the unused section of the cutting blade, and the blade was observed to extend below the guard. a) for band saw near the front, customer service section of the shop; and, b) for the band saw in the back section of the shop near the shear. Alro Metal Services Center was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1910.212(a)(1)), which was contained in OSHA inspection number 877039, citation number 1, item number 4a, and was affirmed as a final order on 08/12/2013 with respect to a workplace located at 12490 49th St. N, Clearwater, FL 33762.
Citation ID 01002
Citaton Type Repeat
Standard Cited 19100178 A04
Issuance Date 2014-05-13
Abatement Due Date 2014-06-09
Current Penalty 5000.0
Initial Penalty 5000.0
Final Order 2014-06-09
Nr Instances 2
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 04/09/2014: a) Front end attachments such as man-lifts were used with forklifts and manufacturers' approval was not obtained for their use; and, b) Slings were used with forklifts to elevate/lift material like a crane with and without an attachment present on the forks. The manufacturer's approval was not obtained for this type of usage. Alro Metal Services Center was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1910.178(a)(4)), which was contained in OSHA inspection number 877039, citation number 2, item number 1, and was affirmed as a final order on 08/12/2013 with respect to a workplace located at 12490 49th St. N, Clearwater, FL 33762.
339667040 0420600 2014-04-08 10223 WOODBERRY RD., TAMPA, FL, 33619
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-04-08
Emphasis L: FORKLIFT, L: EISAX, L: EISAOF, N: SSTARG14, P: SSTARG14
Case Closed 2014-09-29

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100023 E01
Issuance Date 2014-09-03
Abatement Due Date 2014-09-15
Current Penalty 1800.0
Initial Penalty 3000.0
Final Order 2014-09-23
Nr Instances 4
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(e)(1): The railing did not have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level and the intermediate rail was not approximately halfway between the top rail and the floor, platform, runway, or ramp: a) for the establishment doing business as Alro Metals Service Center located at 10223 Woodberry Rd. Tampa (FL) where a guard railing system designed by the employer for the Raymond Order Selector platform that had a top rail measuring 42.5" and a mid rail near the operations panel area measuring 18", as observed on or about April 8, 2014. b) for the establishment doing business as Alro Metals Service Center located at 10223 Woodberry Rd. Tampa (FL) where a guard railing system designed by the employer for the Raymond Order Selector platform section had top rails measuring 42.5" and a mid rail measuring 24.5", as observed on or about April 8, 2014. c) for the establishment doing business as Alro Metals Service Center located at 10223 Woodberry Rd. Tampa (FL) where a guard railing system designed by the employer for the Raymond Order Selector platform had top rails measuring 42.5" and a mid rail section measuring 30.75", as observed on or about April 8, 2014. d) for the establishment doing business as Alro Metals Service Center located at 10223 Woodberry Rd. Tampa (FL) where a guard railing system designed by the employer for the Raymond Order Selector platform section with missing mid rails, as observed on or about April 8, 2014.
Citation ID 02001
Citaton Type Other
Standard Cited 19100132 F01 III
Issuance Date 2014-09-03
Abatement Due Date 2014-09-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-09-23
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(f)(1)(iii): Employee(s) required to use PPE by this section were not trained to know how to don, doff, adjust, and wear PPE: a) for the employer doing business as Alro Metals Service Center located at 10223 Woodberry Rd. Tampa (FL) where an order selecting employee that was required to utilize a fall arrest harness and lanyard while operating a Raymond Order Picker had attempted to don the harness incorrectly. The employee was observed stepping into the harness backward to where the D ring was in the front of their torso, on or about April 8, 2014.
Citation ID 02002
Citaton Type Other
Standard Cited 19100178 A04
Issuance Date 2014-09-03
Abatement Due Date 2014-09-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-09-23
Nr Instances 2
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: (a) for the employer doing business as Alro Metals Service Center located at 10223 Woodberry Rd. Tampa (FL) where modifications were made to Raymond Order Selector, Model 560, Serial #: 560-08-A07237 by fabricating a metal guardrail system, as observed on or about April 8, 2014.
338770399 0420600 2013-02-09 12490 49TH STREET NORTH, CLEARWATER, FL, 33762
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2013-02-09
Case Closed 2015-03-10

Related Activity

Type Accident
Activity Nr 792336

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100132 D01 I
Issuance Date 2013-07-18
Abatement Due Date 2013-07-26
Current Penalty 4000.0
Initial Penalty 4000.0
Final Order 2013-08-12
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, employees operating forklifts did not wear seat belts. The available seat belts were too small to fit some employees, and the practive of wearing seat belts while driving forklifts was not enforced for all employees. Or in the alternative: Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of falling out of forklifts due to seat belts not being worn. a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, employees operating forklifts did not wear seat belts. The available seat belts were too small to fit some employees, and the practice of wearing seat belts while driving forklifts was not enforced for all employees.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100178 L04 III
Issuance Date 2013-07-18
Abatement Due Date 2013-07-30
Current Penalty 7000.0
Initial Penalty 7000.0
Final Order 2013-08-12
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, forklift operators had not received any training or evaluation of their performance in the last three years.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100178 Q07
Issuance Date 2013-07-18
Abatement Due Date 2013-07-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-12
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013: forklifts used at the facility were not inspected/examined before being used. Employees simply started up the forklift and drove off without any safety inspection/examination.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100178 M05 III
Issuance Date 2013-07-18
Abatement Due Date 2013-07-24
Current Penalty 7000.0
Initial Penalty 7000.0
Final Order 2013-08-12
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(m)(5)(iii): When the operator of an industrial truck is dismounted and within 25 ft. of the truck still in his view, the load engaging means shall be fully lowered, controls neutralized, and the brakes set to prevent movement: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, an employee dismounted a forklift without fully lowering the load engaging means; a storage rack was being elevated/held in place by the forks of the forklift. Sometime between 02/08/2013 and 02/09/2013, the storage rack fell from the forklift resulting in the employee below being crushed to death.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2013-07-18
Abatement Due Date 2013-07-30
Current Penalty 4000.0
Initial Penalty 4000.0
Final Order 2013-08-12
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, employees operating a horizontal metal bandsaw were exposed to laceration and amputation hazards associated with a 9 inch, unused section of the bandsaw that was unguarded.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100219 D01
Issuance Date 2013-07-18
Abatement Due Date 2013-08-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-12
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, employees operating and walking by a horizontal metal band saw were exposed to an unguarded, driven belt and pulley. There was no guard on the belt and pulley, and the saw was used in its condition and observed to be plugged in.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100303 G02 I
Issuance Date 2013-07-18
Abatement Due Date 2013-07-25
Current Penalty 5000.0
Initial Penalty 5000.0
Final Order 2013-08-12
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013: an extension cord in the warehouse had damaged insulation resulting in exposed live conductors. The cord was observed to be plugged into an electrical outlet.
Citation ID 01006A
Citaton Type Serious
Standard Cited 19100305 G01 IV A
Issuance Date 2013-07-18
Abatement Due Date 2013-07-26
Current Penalty 4000.0
Initial Penalty 4000.0
Final Order 2013-08-12
Nr Instances 1
Nr Exposed 9
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords were used as a substitute for the fixed wiring of a structure: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013: an extension cord was attached to the wall in the Industrial side of the building and used as fixed wiring. This resulted in a potential fire hazard for employees of the Metals division who walked through the area or worked in the warehouse or other locations of the connected buildings.
Citation ID 01006B
Citaton Type Serious
Standard Cited 19100305 G02 III
Issuance Date 2013-07-18
Abatement Due Date 2013-07-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-12
Nr Instances 1
Nr Exposed 9
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, an extension cord plugged into an outlet had a strain relief problem in that the outer insulation had pulled away from the plug placing tension on the inner terminal screws. This resulted in a potential electric shock or fire hazard for Alro Metal's employees on site or walking through the area.
Citation ID 02001
Citaton Type Other
Standard Cited 19100178 A04
Issuance Date 2013-07-18
Abatement Due Date 2013-07-30
Current Penalty 1000.0
Initial Penalty 1000.0
Final Order 2013-08-12
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013: a) Front end attachments were used with forklifts and manufacturer's approval was not obtained for their use. b) Slings were used with forklifts to elevate/lift material like a crane. Manufacturer's approval was not obtained for this type of usage.
Citation ID 02002
Citaton Type Other
Standard Cited 19100303 B02
Issuance Date 2013-07-18
Abatement Due Date 2013-07-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-12
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, a portable power strip, designed for non-industrial use, was used on the fabrication floor, and an industrial band saw was plugged into it.
Citation ID 02003
Citaton Type Other
Standard Cited 19100303 B07 I
Issuance Date 2013-07-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-12
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment. a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, multiple breakers slots in cabinets were observed to be open and unguarded.
106110216 0418800 1991-05-24 6200 PARK OF COMMERCE, BOCA RATON, FL, 33487
Inspection Type Planned
Scope NoInspection
Safety/Health Safety
Close Conference 1991-05-24
Case Closed 1991-05-24

Date of last update: 01 Apr 2025