343626719
|
0420600
|
2018-11-28
|
10223 WOODBERRY RD, TAMPA, FL, 33619
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-11-29
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2018-11-29
|
Related Activity
Type |
Referral |
Activity Nr |
1399775 |
Safety |
Yes |
|
|
339668311
|
0420600
|
2014-04-09
|
12490 49TH STREET NORTH, CLEARWATER, FL, 33762
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-04-09
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2015-03-10
|
Related Activity
Type |
Inspection |
Activity Nr |
877039 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2014-05-13 |
Abatement Due Date |
2014-06-09 |
Current Penalty |
12750.0 |
Initial Penalty |
15000.0 |
Contest Date |
2014-05-13 |
Final Order |
2014-11-10 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: For the Alro Metal Service Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 04/09/2014. Employees operating a horizontal metal band saws were exposed to laceration hazards due to blade guards which did not cover the bottom cutting section of the blade. As observed, an employees' hands could contact the unused section of the cutting blade, and the blade was observed to extend below the guard. a) for band saw near the front, customer service section of the shop; and, b) for the band saw in the back section of the shop near the shear. Alro Metal Services Center was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1910.212(a)(1)), which was contained in OSHA inspection number 877039, citation number 1, item number 4a, and was affirmed as a final order on 08/12/2013 with respect to a workplace located at 12490 49th St. N, Clearwater, FL 33762. |
|
Citation ID |
01002 |
Citaton Type |
Repeat |
Standard Cited |
19100178 A04 |
Issuance Date |
2014-05-13 |
Abatement Due Date |
2014-06-09 |
Current Penalty |
5000.0 |
Initial Penalty |
5000.0 |
Final Order |
2014-06-09 |
Nr Instances |
2 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 04/09/2014: a) Front end attachments such as man-lifts were used with forklifts and manufacturers' approval was not obtained for their use; and, b) Slings were used with forklifts to elevate/lift material like a crane with and without an attachment present on the forks. The manufacturer's approval was not obtained for this type of usage. Alro Metal Services Center was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1910.178(a)(4)), which was contained in OSHA inspection number 877039, citation number 2, item number 1, and was affirmed as a final order on 08/12/2013 with respect to a workplace located at 12490 49th St. N, Clearwater, FL 33762. |
|
|
339667040
|
0420600
|
2014-04-08
|
10223 WOODBERRY RD., TAMPA, FL, 33619
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-04-08
|
Emphasis |
L: FORKLIFT, L: EISAX, L: EISAOF, N: SSTARG14, P: SSTARG14
|
Case Closed |
2014-09-29
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 E01 |
Issuance Date |
2014-09-03 |
Abatement Due Date |
2014-09-15 |
Current Penalty |
1800.0 |
Initial Penalty |
3000.0 |
Final Order |
2014-09-23 |
Nr Instances |
4 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(e)(1): The railing did not have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level and the intermediate rail was not approximately halfway between the top rail and the floor, platform, runway, or ramp: a) for the establishment doing business as Alro Metals Service Center located at 10223 Woodberry Rd. Tampa (FL) where a guard railing system designed by the employer for the Raymond Order Selector platform that had a top rail measuring 42.5" and a mid rail near the operations panel area measuring 18", as observed on or about April 8, 2014. b) for the establishment doing business as Alro Metals Service Center located at 10223 Woodberry Rd. Tampa (FL) where a guard railing system designed by the employer for the Raymond Order Selector platform section had top rails measuring 42.5" and a mid rail measuring 24.5", as observed on or about April 8, 2014. c) for the establishment doing business as Alro Metals Service Center located at 10223 Woodberry Rd. Tampa (FL) where a guard railing system designed by the employer for the Raymond Order Selector platform had top rails measuring 42.5" and a mid rail section measuring 30.75", as observed on or about April 8, 2014. d) for the establishment doing business as Alro Metals Service Center located at 10223 Woodberry Rd. Tampa (FL) where a guard railing system designed by the employer for the Raymond Order Selector platform section with missing mid rails, as observed on or about April 8, 2014. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100132 F01 III |
Issuance Date |
2014-09-03 |
Abatement Due Date |
2014-09-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-09-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(f)(1)(iii): Employee(s) required to use PPE by this section were not trained to know how to don, doff, adjust, and wear PPE: a) for the employer doing business as Alro Metals Service Center located at 10223 Woodberry Rd. Tampa (FL) where an order selecting employee that was required to utilize a fall arrest harness and lanyard while operating a Raymond Order Picker had attempted to don the harness incorrectly. The employee was observed stepping into the harness backward to where the D ring was in the front of their torso, on or about April 8, 2014. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100178 A04 |
Issuance Date |
2014-09-03 |
Abatement Due Date |
2014-09-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-09-23 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: (a) for the employer doing business as Alro Metals Service Center located at 10223 Woodberry Rd. Tampa (FL) where modifications were made to Raymond Order Selector, Model 560, Serial #: 560-08-A07237 by fabricating a metal guardrail system, as observed on or about April 8, 2014. |
|
|
338770399
|
0420600
|
2013-02-09
|
12490 49TH STREET NORTH, CLEARWATER, FL, 33762
|
|
Inspection Type |
Fat/Cat
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-02-09
|
Case Closed |
2015-03-10
|
Related Activity
Type |
Accident |
Activity Nr |
792336 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100132 D01 I |
Issuance Date |
2013-07-18 |
Abatement Due Date |
2013-07-26 |
Current Penalty |
4000.0 |
Initial Penalty |
4000.0 |
Final Order |
2013-08-12 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, employees operating forklifts did not wear seat belts. The available seat belts were too small to fit some employees, and the practive of wearing seat belts while driving forklifts was not enforced for all employees. Or in the alternative: Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of falling out of forklifts due to seat belts not being worn. a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, employees operating forklifts did not wear seat belts. The available seat belts were too small to fit some employees, and the practice of wearing seat belts while driving forklifts was not enforced for all employees. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100178 L04 III |
Issuance Date |
2013-07-18 |
Abatement Due Date |
2013-07-30 |
Current Penalty |
7000.0 |
Initial Penalty |
7000.0 |
Final Order |
2013-08-12 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, forklift operators had not received any training or evaluation of their performance in the last three years. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100178 Q07 |
Issuance Date |
2013-07-18 |
Abatement Due Date |
2013-07-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-12 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013: forklifts used at the facility were not inspected/examined before being used. Employees simply started up the forklift and drove off without any safety inspection/examination. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100178 M05 III |
Issuance Date |
2013-07-18 |
Abatement Due Date |
2013-07-24 |
Current Penalty |
7000.0 |
Initial Penalty |
7000.0 |
Final Order |
2013-08-12 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(m)(5)(iii): When the operator of an industrial truck is dismounted and within 25 ft. of the truck still in his view, the load engaging means shall be fully lowered, controls neutralized, and the brakes set to prevent movement: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, an employee dismounted a forklift without fully lowering the load engaging means; a storage rack was being elevated/held in place by the forks of the forklift. Sometime between 02/08/2013 and 02/09/2013, the storage rack fell from the forklift resulting in the employee below being crushed to death. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2013-07-18 |
Abatement Due Date |
2013-07-30 |
Current Penalty |
4000.0 |
Initial Penalty |
4000.0 |
Final Order |
2013-08-12 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, employees operating a horizontal metal bandsaw were exposed to laceration and amputation hazards associated with a 9 inch, unused section of the bandsaw that was unguarded. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2013-07-18 |
Abatement Due Date |
2013-08-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-12 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, employees operating and walking by a horizontal metal band saw were exposed to an unguarded, driven belt and pulley. There was no guard on the belt and pulley, and the saw was used in its condition and observed to be plugged in. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100303 G02 I |
Issuance Date |
2013-07-18 |
Abatement Due Date |
2013-07-25 |
Current Penalty |
5000.0 |
Initial Penalty |
5000.0 |
Final Order |
2013-08-12 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013: an extension cord in the warehouse had damaged insulation resulting in exposed live conductors. The cord was observed to be plugged into an electrical outlet. |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2013-07-18 |
Abatement Due Date |
2013-07-26 |
Current Penalty |
4000.0 |
Initial Penalty |
4000.0 |
Final Order |
2013-08-12 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords were used as a substitute for the fixed wiring of a structure: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013: an extension cord was attached to the wall in the Industrial side of the building and used as fixed wiring. This resulted in a potential fire hazard for employees of the Metals division who walked through the area or worked in the warehouse or other locations of the connected buildings. |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 III |
Issuance Date |
2013-07-18 |
Abatement Due Date |
2013-07-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-12 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, an extension cord plugged into an outlet had a strain relief problem in that the outer insulation had pulled away from the plug placing tension on the inner terminal screws. This resulted in a potential electric shock or fire hazard for Alro Metal's employees on site or walking through the area. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100178 A04 |
Issuance Date |
2013-07-18 |
Abatement Due Date |
2013-07-30 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Final Order |
2013-08-12 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013: a) Front end attachments were used with forklifts and manufacturer's approval was not obtained for their use. b) Slings were used with forklifts to elevate/lift material like a crane. Manufacturer's approval was not obtained for this type of usage. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100303 B02 |
Issuance Date |
2013-07-18 |
Abatement Due Date |
2013-07-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-12 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, a portable power strip, designed for non-industrial use, was used on the fabrication floor, and an industrial band saw was plugged into it. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100303 B07 I |
Issuance Date |
2013-07-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-12 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment. a) For the Alro Metal Services Center facility at 12490 49th St. N, Clearwater, FL 33762, as observed on or about 02/11/2013, multiple breakers slots in cabinets were observed to be open and unguarded. |
|
|
106110216
|
0418800
|
1991-05-24
|
6200 PARK OF COMMERCE, BOCA RATON, FL, 33487
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
1991-05-24
|
Case Closed |
1991-05-24
|
|