Entity Name: | SWISHER HYGIENE INTERNATIONAL, INC. |
Jurisdiction: | FLORIDA |
Filing Type: | Foreign Profit |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 28 Feb 2012 (13 years ago) |
Date of dissolution: | 09 Feb 2017 (8 years ago) |
Last Event: | WITHDRAWAL |
Event Date Filed: | 09 Feb 2017 (8 years ago) |
Document Number: | F12000000933 |
FEI/EIN Number |
561541396
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 370 N. Wabasha St., St. Paul, MN, 55102-2233, US |
Mail Address: | 370 N. Wabasha St., St. Paul, MN, 55102-2233, US |
Place of Formation: | NEVADA |
Name | Role | Address |
---|---|---|
HICKEY MICHAEL A | President | 370 N. Wabasha St., St. Paul, MN, 551022233 |
CHEW CHING-MENG | Treasurer | 370 N. Wabasha St., St. Paul, MN, 551022233 |
SEIFERT JAMES J | Secretary | 370 N. Wabasha St., St. Paul, MN, 551022233 |
HICKEY MICHAEL A | Director | 370 N. Wabasha St., St. Paul, MN, 551022233 |
KIRKLAND SCOTT D | Director | 370 N. Wabasha St., St. Paul, MN, 551022233 |
SHERWOOD ROBERT AJr. | Director | 370 N. Wabasha St., St. Paul, MN, 551022233 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
WITHDRAWAL | 2017-02-09 | - | - |
REGISTERED AGENT CHANGED | 2017-02-09 | REGISTERED AGENT REVOKED | - |
CHANGE OF PRINCIPAL ADDRESS | 2016-03-07 | 370 N. Wabasha St., St. Paul, MN 55102-2233 | - |
CHANGE OF MAILING ADDRESS | 2016-03-07 | 370 N. Wabasha St., St. Paul, MN 55102-2233 | - |
Name | Date |
---|---|
Withdrawal | 2017-02-09 |
ANNUAL REPORT | 2016-03-07 |
ANNUAL REPORT | 2015-01-07 |
AMENDED ANNUAL REPORT | 2014-11-04 |
ANNUAL REPORT | 2014-04-02 |
ANNUAL REPORT | 2013-01-04 |
Foreign Profit | 2012-02-28 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
335607594 | 0418800 | 2012-08-06 | 7495 W 2ND COURT, HIALEAH, FL, 33014 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 477950 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100030 A04 |
Issuance Date | 2012-08-30 |
Current Penalty | 3060.0 |
Initial Penalty | 5100.0 |
Final Order | 2012-09-12 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.30(a)(4): Handholds, or other effective means, shall be provided on portable dockboards to permit safe handling. On or about 07/25/2012, the employer did not provide a handlle for the dockboard. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100303 G02 I |
Issuance Date | 2012-08-30 |
Current Penalty | 3780.0 |
Initial Penalty | 6300.0 |
Final Order | 2012-09-12 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On or about 08/06/2012, at 7495 W 2nd Court, Hialeah, Florida. Live parts of electrical equipment were not covered to protect the employees from accidental contact with them on the Jensen Jenroll EXG12. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100178 L06 |
Issuance Date | 2012-08-30 |
Abatement Due Date | 2012-08-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-09-12 |
Nr Instances | 1 |
Nr Exposed | 4 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l) On or about 08/06/12, at 9495 W 2nd Court, Hialeah, Florida, the employees were operating Powered Industrial Truck, for which they had not been trained and certified by the employer in the use and operation of Powered Industrial Truck. |