Search icon

THE BRUSS COMPANY - Florida Company Profile

Branch

Company Details

Entity Name: THE BRUSS COMPANY
Jurisdiction: FLORIDA
Filing Type: Foreign Profit
Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 23 Feb 2012 (13 years ago)
Branch of: THE BRUSS COMPANY, ILLINOIS (Company Number CORP_36270926)
Document Number: F12000000813
FEI/EIN Number 362338268

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2200 W. Don Tyson Parkway, SPRINGDALE, AR, 72762, US
Mail Address: 2200 W. Don Tyson Parkway, SPRINGDALE, AR, 72762, US
Place of Formation: ILLINOIS

Key Officers & Management

Name Role Address
Boulden Melanie President 2200 W. Don Tyson Parkway, SPRINGDALE, AR, 72762
Calaway Curt Director 2200 W. Don Tyson Parkway, SPRINGDALE, AR, 72762
Savells Marissa Secretary 2200 W. Don Tyson Parkway, SPRINGDALE, AR, 72762
McGrath Gordon Director 2200 W. Don Tyson Parkway, SPRINGDALE, AR, 72762
UNITED AGENT GROUP INC. Agent -

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-04-24 2200 W. Don Tyson Parkway, SPRINGDALE, AR 72762 -
CHANGE OF MAILING ADDRESS 2024-04-24 2200 W. Don Tyson Parkway, SPRINGDALE, AR 72762 -
REGISTERED AGENT NAME CHANGED 2023-12-27 UNITED AGENT GROUP INC -
REGISTERED AGENT ADDRESS CHANGED 2023-12-27 801 US HIGHWAY 1, NORTH PALM BEACH, FL 33408 -

Documents

Name Date
ANNUAL REPORT 2024-04-24
Reg. Agent Change 2023-12-27
ANNUAL REPORT 2023-04-28
ANNUAL REPORT 2022-04-28
ANNUAL REPORT 2021-04-30
ANNUAL REPORT 2020-05-27
ANNUAL REPORT 2019-05-01
ANNUAL REPORT 2018-05-01
ANNUAL REPORT 2017-04-27
ANNUAL REPORT 2016-04-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343541421 0419700 2018-10-18 5441 WEST 5TH STREET, JACKSONVILLE, FL, 32254
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-11-06
Case Closed 2018-12-27

Related Activity

Type Referral
Activity Nr 1392315
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100147 D05 I
Issuance Date 2018-11-19
Current Penalty 5543.0
Initial Penalty 5543.0
Final Order 2018-12-05
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: a. On October 16, 2018, the employer's specific procedures for lock out tag out on the Weiler meat grinder did not include a step about waiting for the blade to stop spinning or energy should be at zero state before taking the guard off, exposing employees to an amputation hazard.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100147 C07 I A
Issuance Date 2018-11-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-12-05
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: a. On October 16, 2018, the employer lock out tag out training did not include a verify step about waiting at least 15 to 30 seconds to ensure the blade was completely stopped before removing the guard.