Entity Name: NATIONAL ENERGY HOLDING COMPANY
Jurisdiction: FLORIDA
Filing Type: Foreign Profit
Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 27 Dec 2011 (13 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 14 Oct 2019 (6 years ago)
Document Number: F11000005191
FEI/EIN Number 550716351

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1737 Jessie Street, Jacksonville, FL, 32206, US
Mail Address: 265 INDUSTRIAL DRIVE, BECKLEY, WV, 25801
ZIP code: 32206
County: Duval
Place of Formation: WEST VIRGINIA

Key Officers & Management

Name Role Address
ZANDLO DONNA Secretary 265 INDUSTRIAL DRIVE, BECKLEY, WV, 25801
SMITH S.R. President 265 INDUSTRIAL DRIVE, BECKLEY, WV, 25801
THOMPSON JON Agent 1737 JESSIE STREET, JACKSONVILLE, FL, 32206

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G11000124032 STEELCON SUPPLY COMPANY EXPIRED 2012-01-24 2017-12-31 - 265 INDUSTRIAL DRIVE, BECKLEY, WV, 25801

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2023-01-30 1737 Jessie Street, Jacksonville, FL 32206 -
REGISTERED AGENT NAME CHANGED 2023-01-30 THOMPSON, JON -
REINSTATEMENT 2019-10-14 - -
REVOKED FOR ANNUAL REPORT 2019-09-27 - -
REINSTATEMENT 2014-01-17 - -
REGISTERED AGENT ADDRESS CHANGED 2014-01-17 1737 JESSIE STREET, JACKSONVILLE, FL 32206 -
REVOKED FOR ANNUAL REPORT 2013-09-27 - -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J21000258214 TERMINATED 1000000888965 DUVAL 2021-05-20 2041-05-26 $ 8,226.36 STATE OF FLORIDA, DEPARTMENT OF REVENUE, OUT OF STATE COLLECTIONS UNIT, 1415 W US HIGHWAY 90 STE 115, LAKE CITY FL320556156
J18000166934 TERMINATED 1000000778922 DUVAL 2018-04-20 2038-04-25 $ 5,112.91 STATE OF FLORIDA, DEPARTMENT OF REVENUE, OUT OF STATE COLLECTIONS UNIT, 1415 W US HIGHWAY 90 STE 115, LAKE CITY FL320556156
J14000815448 ACTIVE 1000000548935 DUVAL 2013-10-23 2034-08-01 $ 821.55 STATE OF FLORIDA, DEPARTMENT OF REVENUE, OUT OF STATE COLLECTIONS UNIT, 1401 W US HIGHWAY 90 STE 100, LAKE CITY FL320556123

Documents

Name Date
ANNUAL REPORT 2025-01-14
ANNUAL REPORT 2024-03-23
ANNUAL REPORT 2023-01-30
ANNUAL REPORT 2022-04-27
ANNUAL REPORT 2021-03-15
ANNUAL REPORT 2020-06-02
REINSTATEMENT 2019-10-14
ANNUAL REPORT 2018-03-30
ANNUAL REPORT 2017-02-10
ANNUAL REPORT 2016-06-03

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347259525 0419700 2024-02-06 1737 JESSIE STREET, JACKSONVILLE, FL, 32206
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2024-02-27
Case Closed 2024-03-12

Related Activity

Type Referral
Activity Nr 2121438
Health Yes
347213803 0419700 2024-01-17 1737 JESSIE STREET, JACKSONVILLE, FL, 32206
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-01-18
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2024-06-03

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100022 A03
Issuance Date 2024-04-29
Abatement Due Date 2024-05-23
Current Penalty 2000.0
Initial Penalty 6453.0
Final Order 2024-05-29
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice: a. At the rebar manufacturing shop, on or about January 17, 2024, on the floor around the RMS Shearline motor, the employer exposed employees to slip, trip, and fire hazards, in that oil was allowed to pool on the floor with a damaged power cord emersed in the oil puddle.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2024-04-29
Current Penalty 8000.0
Initial Penalty 11292.0
Final Order 2024-05-29
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. At the rebar manufacturing shop, on or about January 17, 2024, the employer exposed employees to amputation and crushing injuries from the unexpected release of hazardous energy, in that the employer had not performed periodic reviews at least annually of the written energy control procedures that outlined the scope, rules, and steps for the control of hazardous energy for employees required to perform maintenance and service on RMS Hydraulic Shearline, Model 611, S/N: 306, the RMS Rebar Bender Machine, Model 14, S/N: 14-M-401, and the RMS Radial Bender, S/N: 229 industrial machine.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2024-04-29
Current Penalty 8000.0
Initial Penalty 11292.0
Final Order 2024-05-29
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. At the rebar manufacturing shop, on or about January 17, 2024, the employer exposed employees to an amputation hazard, in that the rebar shear unit of the RMS Shearline machine was missing the output protective guard.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100219 D01
Issuance Date 2024-04-29
Current Penalty 4000.0
Initial Penalty 6453.0
Final Order 2024-05-29
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o)(a): b. At the rebar manufacturing shop, on or about January 17, 2024, the employer exposed employees to caught-in hazards from ingoing nip point and rotating parts, in that the infeed and output conveyors of the RMS Shearline machine were missing protective guards for the belt and pulleys transmitting power to drive the conveyor rollers.
Citation ID 01005
Citaton Type Other
Standard Cited 19100305 G02 II
Issuance Date 2024-04-29
Current Penalty 2000.0
Initial Penalty 8067.0
Final Order 2024-05-29
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: a. At the rebar manufacturing shop, on or about January 17, 2024, the employer exposed employees to electric burns and electric shock hazards, in that a 30-amp flexible power cord on the ground at the shear unit was spliced along the length of the cord.
Citation ID 03001
Citaton Type Other
Standard Cited 19100178 L01 I
Issuance Date 2024-04-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-05-29
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a. At the rebar manufacturing shop, on or about January 17, 2024, the employer exposed employees to a struck-by hazard, in that forklift operators had not been trained and evaluated to ensure that they had the necessary knowledge and skills for the safe operation of the vehicle.
Citation ID 03002
Citaton Type Other
Standard Cited 19100305 B02 I
Issuance Date 2024-04-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-05-29
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a. At the rebar manufacturing shop, on or about January 17, 2024, the employer exposed employees to an electric shock hazard, in that, the RMS Shear machine had two open junction boxes missing protective covers, exposing live conductor wires.