Entity Name: | SOUTHERN PRE-ENGINEERED BUILDERS, INC. |
Jurisdiction: | FLORIDA |
Filing Type: | Foreign Profit |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 30 Nov 2011 (13 years ago) |
Branch of: | SOUTHERN PRE-ENGINEERED BUILDERS, INC., MISSISSIPPI (Company Number 521856) |
Date of dissolution: | 09 Dec 2024 (4 months ago) |
Last Event: | WITHDRAWAL |
Event Date Filed: | 09 Dec 2024 (4 months ago) |
Document Number: | F11000004812 |
FEI/EIN Number |
640707597
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 40 DEEP SOUTH LANE, PURVIS, MS, 39475 |
Mail Address: | P.O. BOX 1207, PURVIS, MS, 39475 |
Place of Formation: | MISSISSIPPI |
Name | Role | Address |
---|---|---|
GRAHAM ROBERT J | President | 40 DEEP SOUTH LANE, PURVIS, MS, 39475 |
Williamson Vickie | Secretary | 40 DEEP SOUTH LANE, PURVIS, MS, 39475 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
WITHDRAWAL | 2024-12-09 | - | - |
CHANGE OF MAILING ADDRESS | 2024-12-09 | 40 DEEP SOUTH LANE, PURVIS, MS 39475 | - |
REGISTERED AGENT CHANGED | 2024-12-09 | REGISTERED AGENT REVOKED | - |
Name | Date |
---|---|
WITHDRAWAL | 2024-12-09 |
ANNUAL REPORT | 2024-01-31 |
ANNUAL REPORT | 2023-01-19 |
ANNUAL REPORT | 2022-01-21 |
ANNUAL REPORT | 2021-01-29 |
ANNUAL REPORT | 2020-01-31 |
ANNUAL REPORT | 2019-02-01 |
ANNUAL REPORT | 2018-01-29 |
ANNUAL REPORT | 2017-01-30 |
ANNUAL REPORT | 2016-01-20 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
337969612 | 0419700 | 2012-12-19 | 9950 HUTCHINSON BLVD, PANAMA CITY BEACH, FL, 32408 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2013-01-17 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-02-01 |
Nr Instances | 1 |
Nr Exposed | 8 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about December 19, 2012, employees erecting a steel prefabricated building were not wearing hard hats, exposing themselves to struck by hazards. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 IV |
Issuance Date | 2013-01-17 |
Current Penalty | 1680.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-02-01 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were not standing firmly on the floor of the basket: a. On or about December 19, 2012, on the south side of the building, an employee was observed standing on the mid-rail of a scissor lift, exposing himself to a 15-foot fall hazard. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260251 E08 |
Issuance Date | 2013-01-17 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-02-01 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.251(e)(8): Synthetic web slings were not immediately removed from service if any of the following conditions specified in 1926.251(e)(8)(i) through (e)(8)(v) were present: (i) Acid or caustic burns; (ii) Melting or charring of any part of the sling surface; (iii) snags, punctures, tears, or cuts; (iv) broken or worn stitches; or (v) distortion of fittings. a. On or about December 19, 2012, on the south side of the building, the sling used to lift steel roofing stiffeners had snags, rips, tears, cuts, and broken or worn stitching, exposing employees to being struck by suspended loads. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19100178 L01 I |
Issuance Date | 2013-01-17 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-02-01 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a. On or about December 19, 2012, the operator of the Skytrack forklift was not trained. |
Date of last update: 01 Apr 2025
Sources: Florida Department of State