Entity Name: | SCHEER CONSTRUCTION COMPANY, INC. |
Jurisdiction: | FLORIDA |
Filing Type: | Foreign Profit |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 11 Jun 2010 (15 years ago) |
Branch of: | SCHEER CONSTRUCTION COMPANY, INC., ALABAMA (Company Number 000-124-258) |
Date of dissolution: | 22 Sep 2023 (2 years ago) |
Last Event: | REVOKED FOR ANNUAL REPORT |
Event Date Filed: | 22 Sep 2023 (2 years ago) |
Document Number: | F10000002709 |
FEI/EIN Number |
630979025
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 426 COUNTY ROAD 5, BREMEN, AL, 35033, US |
Mail Address: | 426 COUNTY ROAD 5, BREMEN, AL, 35033, US |
Place of Formation: | ALABAMA |
Name | Role | Address |
---|---|---|
SCHEER, JR. KERMIT A | Agent | 426 County Road 5, Bremen, FL, 350335201 |
SCHEER KERMIT A | President | 426 COUNTY ROAD 5, BREMEN, AL, 35033 |
SCHEER KERMIT A | Director | 426 COUNTY ROAD 5, BREMEN, AL, 35033 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REVOKED FOR ANNUAL REPORT | 2023-09-22 | - | - |
REGISTERED AGENT NAME CHANGED | 2018-01-12 | SCHEER, JR., KERMIT A. | - |
REGISTERED AGENT ADDRESS CHANGED | 2018-01-12 | 426 County Road 5, Bremen, FL 35033-5201 | - |
CHANGE OF MAILING ADDRESS | 2017-01-08 | 426 COUNTY ROAD 5, BREMEN, AL 35033 | - |
CHANGE OF PRINCIPAL ADDRESS | 2011-07-18 | 426 COUNTY ROAD 5, BREMEN, AL 35033 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2022-04-22 |
ANNUAL REPORT | 2021-03-12 |
ANNUAL REPORT | 2020-02-01 |
ANNUAL REPORT | 2019-02-06 |
ANNUAL REPORT | 2018-01-12 |
ANNUAL REPORT | 2017-01-08 |
ANNUAL REPORT | 2016-01-21 |
ANNUAL REPORT | 2015-02-21 |
ANNUAL REPORT | 2014-01-08 |
ANNUAL REPORT | 2013-02-07 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339363780 | 0418800 | 2013-08-27 | 4975 E. SABAL PALM BLVD BLDG 5 UNIT 101, TAMARAC, FL, 33309 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 848269 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 E08 |
Issuance Date | 2013-10-28 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-11-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(8): Direct access to or from another surface was used when the scaffold was more than 14 inches (36 cm) horizontally and/or 24 inches (61 cm) vertically from the other surface: a. On or about August 27, 2013, at the above addressed job site, employees were exposed to a fall hazard while accessing a scaffold from a second floor balcony which exceeded a veritical distance of 24 inches. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 VII |
Issuance Date | 2013-10-28 |
Abatement Due Date | 2013-11-07 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-11-25 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a. On or about August 27, 2013, at the above addressed job site, employees were exposed to a fall hazard while walking/working on a scaffold without using a means of conventional fall protection system. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2013-10-28 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-11-25 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about August 27, 2013, at the above addressed job site, employees were exposed to a fall hazard while painting on the third floor of an open sided balcony without using a means of conventional fall protection. b. On or about August 27, 2013, at the above addressed job site, employees were exposed to a fall hazard while painting on a second floor of an open sided balcony without using a means of conventional fall protection. |
Date of last update: 03 Apr 2025