Entity Name: | JOHN MICHAEL MILLER CONSTRUCTION, INC |
Jurisdiction: | FLORIDA |
Filing Type: | Foreign Profit |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 12 Nov 2008 (16 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 21 Nov 2024 (4 months ago) |
Document Number: | F08000004877 |
FEI/EIN Number |
582435632
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 1425 Morgan Dr, Buckhead, GA, 30625, US |
Mail Address: | PO Box 125, Buckhead, GA, 30625, US |
Place of Formation: | GEORGIA |
Name | Role | Address |
---|---|---|
Miller John M | President | PO Box 125, Buckhead, GA, 30625 |
Miller Laura | Secretary | PO Box 125, Buckhead, GA, 30625 |
Miller Laura | Agent | 7901 4TH STREET N,, ST.PETERSBURG, FL, 33702 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2024-11-21 | 1425 Morgan Dr, Buckhead, GA 30625 | - |
CHANGE OF MAILING ADDRESS | 2024-11-21 | 1425 Morgan Dr, Buckhead, GA 30625 | - |
REVOKED FOR ANNUAL REPORT | 2024-09-27 | - | - |
REGISTERED AGENT NAME CHANGED | 2023-10-03 | Miller, Laura | - |
REINSTATEMENT | 2023-10-03 | - | - |
REVOKED FOR ANNUAL REPORT | 2023-09-22 | - | - |
REGISTERED AGENT ADDRESS CHANGED | 2019-01-28 | 7901 4TH STREET N,, SUITE 300, ST.PETERSBURG, FL 33702 | - |
Name | Date |
---|---|
REINSTATEMENT | 2024-11-21 |
REINSTATEMENT | 2023-10-03 |
ANNUAL REPORT | 2022-04-28 |
ANNUAL REPORT | 2021-02-04 |
ANNUAL REPORT | 2020-07-14 |
ANNUAL REPORT | 2019-04-01 |
ANNUAL REPORT | 2018-03-28 |
ANNUAL REPORT | 2017-01-11 |
ANNUAL REPORT | 2016-01-22 |
ANNUAL REPORT | 2015-01-28 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344122759 | 0420600 | 2019-06-20 | 7920 W. IRLO BRONSON MEMORIAL HWY., KISSIMMEE, FL, 34747 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Repeat |
Standard Cited | 19260453 B02 V |
Issuance Date | 2019-08-14 |
Current Penalty | 0.0 |
Initial Penalty | 8752.0 |
Final Order | 2019-09-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt with lanyard in a fall restrain system or a fall arrest harness attached to the boom or basket was not worn by employee(s) working from an aerial lift: a. On or about 06/20/2019, at the front of the building, an employee was exposed to 13 foot 10 inches fall hazard, in that, a JLG 400S aerial lift was used to gain access to the roof without any type of fall protection. John Michael Miller Construction, Inc. was previously cited for a violation of this Occupational Safety and Health Standard 1926.453(b)(2)(v) which was contained in OSHA inspection number 1073021 citation number 1, item number 4 and was affirmed as a final order on 07/22/2015, with respect to a workplace located at 6476 Strip Ave NW, Canton, OH. |
Citation ID | 01002 |
Citaton Type | Repeat |
Standard Cited | 19260501 B01 |
Issuance Date | 2019-08-14 |
Current Penalty | 0.0 |
Initial Penalty | 8752.0 |
Final Order | 2019-09-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about 06/20/2019, at the front roof area over the entrance to the building, an employee working on a 7.5 to 12 pitch roof was exposed to a 13 foot 10 inches fall hazard while building a dormer window on the roof of the building, without utilizing any type of fall protection. John Michael Miller Construction, Inc. was previously cited for a violation of this Occupational Safety and Health Standard 1926.501(b)(1), which was contained in OSHA inspection number 1299907 citation number 1, item number 1 and was affirmed as a final order on 08/01/2018, with respect to a workplace located at 25830 Sierra Center Blvd, Lutz, FL. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2018-08-22 |
Emphasis | L: FALL |
Case Closed | 2018-11-21 |
Related Activity
Type | Referral |
Activity Nr | 1375157 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 IV |
Issuance Date | 2018-10-09 |
Abatement Due Date | 2018-10-15 |
Current Penalty | 3414.6 |
Initial Penalty | 5691.0 |
Final Order | 2018-11-08 |
Nr Instances | 2 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(iv): Employees did not stand firmly on the floor of the basket, and climbed on the edge of the basket for a work position: On or about 08/22/2018; Location: Front gazebo under construction; 1) Two employees framing the gazebo in front of the construction site climbed over the rails of a scissor lift basket and were exposed to fall hazards approximately 18ft from ground level. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260454 C03 |
Issuance Date | 2018-10-09 |
Abatement Due Date | 2018-10-26 |
Current Penalty | 1951.2 |
Initial Penalty | 3252.0 |
Final Order | 2018-11-08 |
Nr Instances | 2 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(c)(3): When the employer has reason to believe that an employee lacks the skill or understanding needed for safe work, the employer did not retrain each such employee so that the requisite proficiency is regained. Retraining is required because the following situation: Where inadequacies in an affected employee's work involving scaffolds indicate that the employee has not retained the requisite proficiency: On or about 08/22/2018; Location: Front gazebo under construction; 1) Two employees framing the gazebo in front of the construction site climbed over the rails of a scissor lift basket and were exposed to fall hazards approximately 18ft from ground level, were not retrained to demonstrate safety proficiency while working on a scaffold. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2018-03-07 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2018-08-09 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2018-07-05 |
Abatement Due Date | 2018-07-17 |
Current Penalty | 1330.2 |
Initial Penalty | 2217.0 |
Final Order | 2018-08-08 |
Nr Instances | 3 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) The roof in the front entrance of the site - an employee was exposed to a fall of 9 feet while installing trusses, employee was wearing his harness but was not tied off, on or about 3/7/18. b) The roof in the front entrance of the site - an employee was exposed to a fall of 9 feet while cleaning up material on the roof, employee was wearing his harness but was not tied off, on or about 3/7/18. c) The roof in the front entrance of the site - the foreman was exposed to a fall of 9 feet while supervising on the roof, the foreman was wearing his harness but was not tied off, on or about 3/7/18. |
Date of last update: 02 Mar 2025
Sources: Florida Department of State