Search icon

JOHN MICHAEL MILLER CONSTRUCTION, INC - Florida Company Profile

Company Details

Entity Name: JOHN MICHAEL MILLER CONSTRUCTION, INC
Jurisdiction: FLORIDA
Filing Type: Foreign Profit
Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 12 Nov 2008 (16 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 21 Nov 2024 (4 months ago)
Document Number: F08000004877
FEI/EIN Number 582435632

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1425 Morgan Dr, Buckhead, GA, 30625, US
Mail Address: PO Box 125, Buckhead, GA, 30625, US
Place of Formation: GEORGIA

Key Officers & Management

Name Role Address
Miller John M President PO Box 125, Buckhead, GA, 30625
Miller Laura Secretary PO Box 125, Buckhead, GA, 30625
Miller Laura Agent 7901 4TH STREET N,, ST.PETERSBURG, FL, 33702

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-11-21 1425 Morgan Dr, Buckhead, GA 30625 -
CHANGE OF MAILING ADDRESS 2024-11-21 1425 Morgan Dr, Buckhead, GA 30625 -
REVOKED FOR ANNUAL REPORT 2024-09-27 - -
REGISTERED AGENT NAME CHANGED 2023-10-03 Miller, Laura -
REINSTATEMENT 2023-10-03 - -
REVOKED FOR ANNUAL REPORT 2023-09-22 - -
REGISTERED AGENT ADDRESS CHANGED 2019-01-28 7901 4TH STREET N,, SUITE 300, ST.PETERSBURG, FL 33702 -

Documents

Name Date
REINSTATEMENT 2024-11-21
REINSTATEMENT 2023-10-03
ANNUAL REPORT 2022-04-28
ANNUAL REPORT 2021-02-04
ANNUAL REPORT 2020-07-14
ANNUAL REPORT 2019-04-01
ANNUAL REPORT 2018-03-28
ANNUAL REPORT 2017-01-11
ANNUAL REPORT 2016-01-22
ANNUAL REPORT 2015-01-28

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344122759 0420600 2019-06-20 7920 W. IRLO BRONSON MEMORIAL HWY., KISSIMMEE, FL, 34747
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-06-20
Emphasis L: FALL, P: FALL
Case Closed 2019-09-24

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260453 B02 V
Issuance Date 2019-08-14
Current Penalty 0.0
Initial Penalty 8752.0
Final Order 2019-09-24
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt with lanyard in a fall restrain system or a fall arrest harness attached to the boom or basket was not worn by employee(s) working from an aerial lift: a. On or about 06/20/2019, at the front of the building, an employee was exposed to 13 foot 10 inches fall hazard, in that, a JLG 400S aerial lift was used to gain access to the roof without any type of fall protection. John Michael Miller Construction, Inc. was previously cited for a violation of this Occupational Safety and Health Standard 1926.453(b)(2)(v) which was contained in OSHA inspection number 1073021 citation number 1, item number 4 and was affirmed as a final order on 07/22/2015, with respect to a workplace located at 6476 Strip Ave NW, Canton, OH.
Citation ID 01002
Citaton Type Repeat
Standard Cited 19260501 B01
Issuance Date 2019-08-14
Current Penalty 0.0
Initial Penalty 8752.0
Final Order 2019-09-24
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about 06/20/2019, at the front roof area over the entrance to the building, an employee working on a 7.5 to 12 pitch roof was exposed to a 13 foot 10 inches fall hazard while building a dormer window on the roof of the building, without utilizing any type of fall protection. John Michael Miller Construction, Inc. was previously cited for a violation of this Occupational Safety and Health Standard 1926.501(b)(1), which was contained in OSHA inspection number 1299907 citation number 1, item number 1 and was affirmed as a final order on 08/01/2018, with respect to a workplace located at 25830 Sierra Center Blvd, Lutz, FL.
343417879 0418800 2018-08-22 3339 NORTH FEDERAL HIGHWAY, OAKLAND PARK, FL, 33306
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-08-22
Emphasis L: FALL
Case Closed 2018-11-21

Related Activity

Type Referral
Activity Nr 1375157
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 IV
Issuance Date 2018-10-09
Abatement Due Date 2018-10-15
Current Penalty 3414.6
Initial Penalty 5691.0
Final Order 2018-11-08
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(iv): Employees did not stand firmly on the floor of the basket, and climbed on the edge of the basket for a work position: On or about 08/22/2018; Location: Front gazebo under construction; 1) Two employees framing the gazebo in front of the construction site climbed over the rails of a scissor lift basket and were exposed to fall hazards approximately 18ft from ground level.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260454 C03
Issuance Date 2018-10-09
Abatement Due Date 2018-10-26
Current Penalty 1951.2
Initial Penalty 3252.0
Final Order 2018-11-08
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(c)(3): When the employer has reason to believe that an employee lacks the skill or understanding needed for safe work, the employer did not retrain each such employee so that the requisite proficiency is regained. Retraining is required because the following situation: Where inadequacies in an affected employee's work involving scaffolds indicate that the employee has not retained the requisite proficiency: On or about 08/22/2018; Location: Front gazebo under construction; 1) Two employees framing the gazebo in front of the construction site climbed over the rails of a scissor lift basket and were exposed to fall hazards approximately 18ft from ground level, were not retrained to demonstrate safety proficiency while working on a scaffold.
342999075 0420600 2018-03-07 25830 SIERRA CENTER BLVD, LUTZ, FL, 33559
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-03-07
Emphasis L: FALL, P: FALL
Case Closed 2018-08-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2018-07-05
Abatement Due Date 2018-07-17
Current Penalty 1330.2
Initial Penalty 2217.0
Final Order 2018-08-08
Nr Instances 3
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) The roof in the front entrance of the site - an employee was exposed to a fall of 9 feet while installing trusses, employee was wearing his harness but was not tied off, on or about 3/7/18. b) The roof in the front entrance of the site - an employee was exposed to a fall of 9 feet while cleaning up material on the roof, employee was wearing his harness but was not tied off, on or about 3/7/18. c) The roof in the front entrance of the site - the foreman was exposed to a fall of 9 feet while supervising on the roof, the foreman was wearing his harness but was not tied off, on or about 3/7/18.