Search icon

ROSWELL MASONRY, INC. - Florida Company Profile

Company Details

Entity Name: ROSWELL MASONRY, INC.
Jurisdiction: FLORIDA
Filing Type: Foreign Profit
Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 14 May 2007 (18 years ago)
Document Number: F07000002603
FEI/EIN Number 582256901

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 6175 HICKORY FLAT HIGHWAY, SUITE 110, CANTON, GA, 30115
Mail Address: 6175 HICKORY FLAT HIGHWAY, SUITE 110, CANTON, GA, 30115
Place of Formation: GEORGIA

Key Officers & Management

Name Role Address
NEWSOM LARRY President 101 AVERY ESTATES DRIVE, CANTON, GA, 30115
NEWSOM SUSAN Vice President 101 AVERY ESTATES DR, CANTON, GA, 30115
CORPORATION SERVICE COMPANY Agent -

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2013-05-06 CORPORATION SERVICE COMPANY -
REGISTERED AGENT ADDRESS CHANGED 2013-05-06 1201 HAYS STREET, TALLAHASSEE, FL 32301 -

Documents

Name Date
ANNUAL REPORT 2025-01-15
ANNUAL REPORT 2024-01-29
ANNUAL REPORT 2023-01-26
ANNUAL REPORT 2022-01-20
ANNUAL REPORT 2021-02-10
ANNUAL REPORT 2020-01-14
ANNUAL REPORT 2019-02-18
ANNUAL REPORT 2018-01-22
ANNUAL REPORT 2017-01-12
ANNUAL REPORT 2016-01-22

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
337601413 0420600 2012-11-29 750 N. ORANGE AVE, ORLANDO, FL, 32801
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2012-11-29
Emphasis L: EISAOF, L: FALL, P: FALL
Case Closed 2014-09-04

Related Activity

Type Inspection
Activity Nr 760063
Safety Yes
Type Inspection
Activity Nr 760267
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B04
Issuance Date 2012-12-17
Abatement Due Date 2012-12-21
Current Penalty 1800.0
Initial Penalty 2000.0
Final Order 2013-01-11
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(4): Each end of a platform, which was not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches: a. At the north side of the building, employees were exposed to a fall hazard 30 feet high, in that, scaffold platforms extended as little as 2 inches from the scaffold support frames.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 B05 I
Issuance Date 2012-12-17
Abatement Due Date 2012-12-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-01-11
Nr Instances 12
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length, extended over its support more than 12 inches: a. At the north side of the building, employees were exposed to a fall hazard 30 feet high, in that, scaffold platforms extended as much as 3 feet at their scaffold end support frame.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2012-12-17
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2013-01-11
Nr Instances 3
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a. North side of the building, employees were exposed to a 33 feet fall hazard while on a scaffold 5 frames high where guardrails were not installed at the scaffold ends. Employees were standing right at the edge of the scaffold end installing bricks at the exterior of the building without any fall protection. b. East side of the building, employees were exposed to a 33 feet fall hazard while on a scaffold 5 frames high where guardrails were not installed at the scaffold ends. Employees were standing right at the edge of the scaffold end installing bricks at the exterior of the building without any fall protection.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 C01
Issuance Date 2012-12-17
Abatement Due Date 2012-12-21
Current Penalty 2500.0
Initial Penalty 2800.0
Final Order 2013-01-11
Nr Instances 10
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. a. North side of the building, employees were exposed to a 33 feet fall hazard, in that, 10 single standing scaffold towers 5 frames high were not tied to the building at least once to prevent them from tipping over. The scaffold frames were 5 feet wide thus requiring at least one tie off point at 26 feet high.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02 II
Issuance Date 2012-12-17
Abatement Due Date 2012-12-21
Current Penalty 0.0
Initial Penalty 2000.0
Final Order 2013-01-11
Nr Instances 4
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: a. At the north and east side of the building, a tubular welded frame scaffold 5 frames high was used to reach elevations at the exterior of the building during brick wall construction with the scaffold legs supported on cement blocks and boards that could become displaced.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2012-12-17
Current Penalty 2500.0
Initial Penalty 2800.0
Final Order 2013-01-11
Nr Instances 5
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. At the north side of the building, employees were exposed to a 30 feet fall hazards, in that, the railings on 5 balconies were removed during exterior brick installation and not replaced. While on the balconies employees were not protected from falling to the ground.