Search icon

SEVERN TRENT SERVICES, INC. - Florida Company Profile

Company Details

Entity Name: SEVERN TRENT SERVICES, INC.
Jurisdiction: FLORIDA
Filing Type: Foreign Profit
Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 04 Aug 2006 (19 years ago)
Date of dissolution: 07 Aug 2017 (8 years ago)
Last Event: WITHDRAWAL
Event Date Filed: 07 Aug 2017 (8 years ago)
Document Number: F06000005147
FEI/EIN Number 232660702

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 220 Gibraltar Road, Horsham, PA, 19044, US
Mail Address: 220 Gibraltar Road, Horsham, PA, 19044, US
Place of Formation: PENNSYLVANIA

Key Officers & Management

Name Role Address
CORPORATION SERVICE COMPANY Agent -
Turnbull Chris Secretary 220 Gibraltar Road, Horsham, PA, 19044
Freebody John Chief Financial Officer 220 Gibraltar Road, Horsham, PA, 19044
Bouvier Stephanie President 220 Gibraltar Road, Horsham, PA, 19044

Events

Event Type Filed Date Value Description
WITHDRAWAL 2017-08-07 - -
CHANGE OF MAILING ADDRESS 2016-04-19 220 Gibraltar Road, Suite 200, Horsham, PA 19044 -
CHANGE OF PRINCIPAL ADDRESS 2016-04-19 220 Gibraltar Road, Suite 200, Horsham, PA 19044 -
REGISTERED AGENT ADDRESS CHANGED 2015-09-16 1201 HAYS STREET, TALLAHASSEE, FL 32301-2525 -
REGISTERED AGENT NAME CHANGED 2015-09-16 CORPORATION SERVICE COMPANY -
CANCEL ADM DISS/REV 2009-10-08 - -
REVOKED FOR ANNUAL REPORT 2009-09-25 - -
REINSTATEMENT 2007-10-29 - -
REVOKED FOR ANNUAL REPORT 2007-09-14 - -

Documents

Name Date
WITHDRAWAL 2017-08-07
ANNUAL REPORT 2017-04-10
ANNUAL REPORT 2016-04-19
Reg. Agent Change 2015-09-16
ANNUAL REPORT 2015-01-12
ANNUAL REPORT 2014-01-07
ANNUAL REPORT 2013-01-24
ANNUAL REPORT 2012-01-04
ANNUAL REPORT 2011-02-15
ANNUAL REPORT 2010-02-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341895878 0418800 2016-11-07 16500 NW 97TH AVE., HIALEAH, FL, 33018
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2016-11-07
Case Closed 2017-02-15

Related Activity

Type Complaint
Activity Nr 1151696
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19100134 C01
Issuance Date 2017-01-23
Abatement Due Date 2017-02-16
Current Penalty 4000.0
Initial Penalty 5432.0
Final Order 2017-02-14
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about November 7th, 2016, at the worksite located at 16500 NW 97th Ave. Hialeah, FL 33018, the employer did not develop and implement a written respiratory protection program for employee(s) who are required to wear respiratory protection such as but not limited to 3M filtering piece-face N-95, MSA elastomeric half mask respirator, SCOTT elastomeric full-face mask, and a MSA self-contained breathing apparatus.
Citation ID 01001B
Citaton Type Other
Standard Cited 19100134 E01
Issuance Date 2017-01-23
Abatement Due Date 2017-02-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-02-14
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about November 7th, 2016, at the worksite located at 16500 NW 97th Ave. Hialeah, FL 33018, the employer did not provide a medical evaluation for employees who use 3M filtering piece-face N-95, MSA elastomeric half mask respirator, SCOTT elastomeric full-face mask , and a MSA self-contained breathing apparatus.
Citation ID 01001C
Citaton Type Other
Standard Cited 19100134 F02
Issuance Date 2017-01-23
Abatement Due Date 2017-02-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-02-14
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: On or about November 7th, 2016, at the worksite located at 16500 NW 97th Ave. Hialeah, FL 33018, the employer did not provide fit test for employees who are using tight-fitting facepiece such as but no limited to MSA elastomeric half mask respirator, 3M elastomeric half mask respirator, SCOTT elastomeric full-face mask , and a MSA self-contained breathing apparatus.
Citation ID 01001D
Citaton Type Other
Standard Cited 19100134 K
Issuance Date 2017-01-23
Abatement Due Date 2017-02-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-02-14
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: On or about November 7th, 2016, at the worksite located at 16500 NW 97th Ave. Hialeah, FL 33018, the employer did not provide respirator information training in the use and care annually, for employees who use 3M filtering piece-face N-95, MSA elastomeric half mask respirator, SCOTT elastomeric full-face mask , and a MSA self-contained breathing apparatus for its use while performing samplings, connections and regular/emergency operations.

Date of last update: 02 Apr 2025

Sources: Florida Department of State