Search icon

MAP INDUSTRIES LF, INC. - Florida Company Profile

Company Details

Entity Name: MAP INDUSTRIES LF, INC.
Jurisdiction: FLORIDA
Filing Type: Foreign Profit
Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 21 Mar 2006 (19 years ago)
Document Number: F06000001871
FEI/EIN Number 621608135

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 987 Industrial Drive, Bldg # 1, Chipley, FL, 32428, US
Mail Address: P.O. BOX 30458, CLARKSVILLE, TN, 37040
ZIP code: 32428
County: Washington
Place of Formation: TENNESSEE

Key Officers & Management

Name Role Address
Patton Christopher Chief Financial Officer P.O. BOX 30458, CLARKSVILLE, TN, 37040
BRADLEY III EARL Secretary P.O. BOX 30458, CLARKSVILLE, TN, 37040
BRADLEY III EARL Director P.O. BOX 30458, CLARKSVILLE, TN, 37040
Bradley IV Earl President P.O. BOX 30458, CLARKSVILLE, TN, 37040
Youngquest Glenda Agent 987 Industrial Drive, Chipley, FL, 32428

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G07346900023 OEM TUBE ASSEMBLIES ACTIVE 2007-12-10 2027-12-31 - 987 INDUSTRAIL DRIVE,BLDG #1, CHIPLEY, FL, 32428

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2021-07-27 Youngquest, Glenda -
REGISTERED AGENT ADDRESS CHANGED 2021-07-27 987 Industrial Drive, Bldg # 1, Chipley, FL 32428 -
CHANGE OF PRINCIPAL ADDRESS 2019-06-21 987 Industrial Drive, Bldg # 1, Chipley, FL 32428 -

Documents

Name Date
ANNUAL REPORT 2024-03-26
ANNUAL REPORT 2023-02-15
ANNUAL REPORT 2022-01-24
ANNUAL REPORT 2021-07-27
ANNUAL REPORT 2020-04-29
ANNUAL REPORT 2019-06-21
ANNUAL REPORT 2018-04-02
ANNUAL REPORT 2017-04-12
ANNUAL REPORT 2016-03-15
ANNUAL REPORT 2015-04-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341668036 0419700 2016-08-02 700 ABERDEEN LOOP SUITE A-B, PANAMA CITY, FL, 32405
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2016-08-03
Emphasis N: AMPUTATE
Case Closed 2017-01-13

Related Activity

Type Complaint
Activity Nr 1119588
Safety Yes
Type Inspection
Activity Nr 1166819
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100147 C04 I
Issuance Date 2016-11-17
Current Penalty 4489.2
Initial Penalty 7482.0
Final Order 2016-12-14
Nr Instances 4
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. On or about August 2, 2016, at MAP Industries LF, Inc., the employer did not develop and utilize energy control procedures for their employees while they were required to perform maintenance by changing hose fittings and changing out the tooling and blades on the Burr Oak cut to length machine Model STC08. Employees are exposed to pinching, crushing and amputations. b. On or about August 2, 2016, at MAP Industries LF, Inc., the employer did not develop and utilize energy control procedures for their employees while they were required to perform maintenance by changing hose fittings and changing out the tooling and blades on the Burr Oak cut to length machine Model STC0. Employees are exposed to pinching, crushing and amputations. c. On or about August 2, 2016, at MAP Industries LF, Inc., the employer did not develop and utilize energy control procedures for their employees while they were required to perform maintenance by changing hose fittings and changing out the tooling and blades on the T-Drill cut to length machine Model TCC-45. Employees are exposed to pinching, crushing and amputations. d. On or about August 2, 2016, at MAP Industries LF, Inc., the employer did not develop and utilize energy control procedures for their employees while they were required to perform maintenance by changing hose fittings and changing out the tooling and blades on the T-Drill cut to length machine Model 311-36. Employees are exposed to pinching, crushing and amputations.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2016-11-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-12-14
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. On or about August 2, 2016 at MAP Industries LF, Inc., the employer did not conduct periodic inspections at least annually on lockout/tagout (LOTO) procedures and requirements. Employees were not locking out machines when changing tooling and blades and did not have record of periodic inspections for the machines they operated. Employees are exposed to pinching, crushing, amputations and permanent disabling injuries.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100147 C07 I
Issuance Date 2016-11-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-12-14
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a. On or about August 2, 2016, at MAP Industries, LF, Inc. the employer did not provide training to employees servicing the cut to length machines about the hazards and procedures to minimize those hazards. Employees were exposed to crushing, amputations and disabiliting injuries.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2016-11-17
Current Penalty 4489.2
Initial Penalty 7482.0
Final Order 2016-12-14
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about August 2, 2016, at MAP Industries LF, Inc., the employer by-passed a safety lock disconnect switch while operating the Burr Oak cut to length machine Model STC0. Employees are exposed to pinching, crushing and amputations.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100212 A02
Issuance Date 2016-11-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-12-14
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: a. On or about August 2, 2016 on the east side of the facility, employees were using a T-Drill cut to length machine Model # 215.that was not guarded by a barrier around the feeding rollers, exposing employees to cuts, bruises, and amputation hazards.