Entity Name: | UNITED STEEL PRODUCTS COMPANY, INC. |
Jurisdiction: | FLORIDA |
Filing Type: | Foreign Profit |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 06 Mar 2000 (25 years ago) |
Branch of: | UNITED STEEL PRODUCTS COMPANY, INC., MINNESOTA (Company Number b1d6b7a1-a7d4-e011-a886-001ec94ffe7f) |
Date of dissolution: | 21 Dec 2012 (12 years ago) |
Last Event: | WITHDRAWAL |
Event Date Filed: | 21 Dec 2012 (12 years ago) |
Document Number: | F00000001203 |
FEI/EIN Number |
410914525
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 14515 NORTH OUTER FORTY DRIVE, SUITE 300, CHESTERFIELD, MO, 63017, US |
Mail Address: | 14515 NORTH OUTER FORTY DRIVE, SUITE 300, CHESTERFIELD, MO, 63017, US |
Place of Formation: | MINNESOTA |
Name | Role | Address |
---|---|---|
C T CORPORATION SYSTEM | Agent | - |
DIAB MAGED | President | 14515 NORTH OUTER FORTY DRIVE, SUITE 300, CHESTERFIELD, MO, 63017 |
CARR JOSEPH C | Secretary | 14515 NORTH OUTER FORTY DRIVE, SUITE 300, CHESTERFIELD, MO, 63017 |
BURKHARDT RONALD S | Chief Financial Officer | 14515 NORTH OUTER FORTY DRIVE, SUITE 300, CHESTERFIELD, MO, 63017 |
MANENTI THOMAS J | Director | 14515 NORTH OUTER FORTY DRIVE, SUITE 300, CHESTERFIELD, MO, 63017 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
WITHDRAWAL | 2012-12-21 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2012-02-08 | 14515 NORTH OUTER FORTY DRIVE, SUITE 300, CHESTERFIELD, MO 63017 | - |
CHANGE OF MAILING ADDRESS | 2012-02-08 | 14515 NORTH OUTER FORTY DRIVE, SUITE 300, CHESTERFIELD, MO 63017 | - |
NAME CHANGE AMENDMENT | 2006-08-23 | UNITED STEEL PRODUCTS COMPANY, INC. | - |
Name | Date |
---|---|
Withdrawal | 2012-12-21 |
ANNUAL REPORT | 2012-02-08 |
ANNUAL REPORT | 2011-03-17 |
ANNUAL REPORT | 2010-04-09 |
ANNUAL REPORT | 2009-03-20 |
ANNUAL REPORT | 2008-04-18 |
ANNUAL REPORT | 2007-04-18 |
Name Change | 2006-08-23 |
ANNUAL REPORT | 2006-08-08 |
ANNUAL REPORT | 2006-04-26 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339335044 | 0420600 | 2013-08-21 | 11910 62ND STREET NORTH, LARGO, FL, 33773 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 840459 |
Health | Yes |
Inspection Type | Fat/Cat |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2013-07-11 |
Emphasis | L: FORKLIFT |
Related Activity
Type | Accident |
Activity Nr | 825929 |
Type | Inspection |
Activity Nr | 948234 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 5A0001 |
Issuance Date | 2013-12-20 |
Abatement Due Date | 2013-12-31 |
Current Penalty | 7000.0 |
Initial Penalty | 7000.0 |
Contest Date | 2014-01-14 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazard while offloading vertically loaded steel coils with weights greater than 4000 pounds that were insufficiently cribbed and unsafely positioned on the flatbed of a trailer. a. On or about 06/25/2013, steel coil offload area - employees were exposed to struck-by and caught-in hazards when using a forklift to offload vertically loaded steel coils with weights greater than 4000 pounds from a flatbed trailer, which were insufficiently cribbed and unsafely postioned. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100106 E09 III |
Issuance Date | 2013-12-20 |
Abatement Due Date | 2013-12-31 |
Current Penalty | 3000.0 |
Initial Penalty | 3000.0 |
Contest Date | 2014-01-14 |
Nr Instances | 1 |
Nr Exposed | 20 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: a. On or about 06/25/2013, press room #2 - the container used for the disposal of flammable waste material such as WD-40, CRC Brakleen brake parts cleaner and other combustible products was not covered. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2013-12-20 |
Abatement Due Date | 2014-01-08 |
Current Penalty | 3000.0 |
Initial Penalty | 3000.0 |
Contest Date | 2014-01-14 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about 06/25/2013, press room # 2 - pinch points on powered label conveyors were not guarded. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100303 B02 |
Issuance Date | 2013-12-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2014-01-14 |
Nr Instances | 1 |
Nr Exposed | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. On or about 06/25/2013, press room # 2 - the non-metallic sheath cable used to energize a receptacle was not enclosed in conduit. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19100305 G02 II |
Issuance Date | 2013-12-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2014-01-14 |
Nr Instances | 1 |
Nr Exposed | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.305(g)(2)(ii): Flexible cords were not used in continuous lengths without splice or tap: a. On or about 06/25/2013, press room #2 - the flexible cord connected to the pedal switch on press #18 was repaired with electrical tape. |
Date of last update: 01 Apr 2025