346570245
|
0420600
|
2023-03-16
|
705 MAIN STREET, AUBURNDALE, FL, 33823
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-03-16
|
Emphasis |
N: CHEMNEP
|
Case Closed |
2023-08-23
|
Related Activity
Type |
Referral |
Activity Nr |
2010508 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1657028 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1657031 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100119 D03 I B |
Issuance Date |
2023-07-13 |
Abatement Due Date |
2023-08-15 |
Current Penalty |
15625.0 |
Initial Penalty |
15625.0 |
Final Order |
2023-08-07 |
Nr Instances |
6 |
Nr Exposed |
625 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.119(d)(3)(i)(B): The employer's piping and instrument diagrams were not accurate and did not represent equipment that was existing and was part of the process. a) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/23, a ? inch Hansen HGV1 Long Neck Service/Gauge Valve located on piping associated with suction accumulator V-33 and downstream of an 8-inch isolation/stop valve, RL-1, was not depicted on the employer?s piping and instrumentation diagrams. b) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/23, pressure gauge at a ? inch service/gauge valve on piping associated with suction accumulator V-33 and downstream of an 8-inch isolation/stop valve, RL-1, was not depicted on the employer?s piping and instrumentation diagrams. c) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/23, valve RL-1/CH-31 was incorrectly field-labeled with respect to piping and instrumentation drawing number V-33A. d) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/23, five valves at high pressure receiver V23 had illegible valve tags for valves depicted on piping and instrumentation drawing number V-23. e) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/23, chiller CH-31 and isolation/stop valve RL-1/V-33 were located on the wrong side of the suction accumulator V-33 with respect to the level column on the piping and instrumentation drawing number V-33A. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100119 D03 II |
Issuance Date |
2023-07-13 |
Abatement Due Date |
2023-08-15 |
Current Penalty |
0.0 |
Initial Penalty |
15625.0 |
Final Order |
2023-08-07 |
Nr Instances |
6 |
Nr Exposed |
625 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices. a) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 03/15/2023, the employer exposed employees to inhalation and skin contact hazards associated with a catastrophic release of pressurized liquid anhydrous ammonia, in that, a pressure gauge and its 1/4 inch service/gauge valve on a 25,000 lb. approximate ammonia suction accumulator vessel V-33 was inoperable and not able to be read. Line breaking activities were commencing at/near the gauge location, and contractors involved were unable to get an accurate read of the pressure inside the pipe where line breaking was going to commence. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100119 J04 I |
Issuance Date |
2023-07-13 |
Abatement Due Date |
2023-08-15 |
Current Penalty |
15625.0 |
Initial Penalty |
15625.0 |
Final Order |
2023-08-07 |
Nr Instances |
3 |
Nr Exposed |
625 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.119(j)(4)(i): The employer did not perform inspection and tests on process equipment. a) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/2023, the employer failed to perform inspections and tests on isolation/stop valve RL-1/V-33. b) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/2023, the employer failed to perform inspections and tests on a Hansen HGV1 Long Neck ?? gauge/service valve which was installed downstream of isolation/stop valve RL-1/V-33 on suction accumulator 33. A Gritty material had accumulated in the gauge/service valve. c) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/2023, the employer failed to perform inspections and tests on a Hansen HGV1 Long Neck ?? gauge/service valve which was installed downstream of isolation/stop valve RL-1/V-33 on suction accumulator 33. The gauge was inoperable and unable to be read. |
|
|
342110749
|
0420600
|
2017-02-16
|
427 SAN CHRISTOPHER DR., DUNEDIN, FL, 34698
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-02-16
|
Emphasis |
N: AMPUTATE, L: FORKLIFT, P: AMPUTATE
|
Case Closed |
2017-06-16
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100037 B04 |
Issuance Date |
2017-05-19 |
Abatement Due Date |
2017-06-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-06-16 |
Nr Instances |
1 |
Nr Exposed |
100 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: a) On or about 02/16/2017 in building # 427, in the manufacturing/production areas, the employer did not provide directional exit signs that were in line-of-sight for employees possibly exposed to fire hazards. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100303 G01 VII A 1 |
Issuance Date |
2017-05-19 |
Abatement Due Date |
2017-06-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-06-16 |
Nr Instances |
1 |
Nr Exposed |
15 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1)(vii)(A)(1): The space equal to the width and depth of the equipment and extending from the floor to a height of 1.83 m (6.0 ft) above the equipment or to the structural ceiling, whichever is lower, was not dedicated to the electrical installation. a) On or about 02-16-2017 at bldg. 427 in the hallway in front of the filling room, the electrical panels were not protected from industrial vehicles and/or accidental contact by unauthorized personnel, employees were exposed to an electrical shock hazard. |
|
|
342116456
|
0420600
|
2017-02-15
|
5901 EAST FOWLER AVE, TAMPA, FL, 33617
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-02-15
|
Case Closed |
2017-02-22
|
Related Activity
Type |
Complaint |
Activity Nr |
1171496 |
Health |
Yes |
|
|
339798472
|
0420600
|
2014-06-06
|
2501 W. ORANGE AVE., APOPKA, FL, 32703
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2014-09-08
|
Case Closed |
2014-10-07
|
Related Activity
Type |
Complaint |
Activity Nr |
891765 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
979853 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 F03 II D |
Issuance Date |
2014-09-11 |
Abatement Due Date |
2014-10-07 |
Current Penalty |
1980.0 |
Initial Penalty |
3300.0 |
Final Order |
2014-10-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: a) Building C - Operations employees, cleaning out the inside of a tank with a hose, were not qualified to lock out the equipment and maintenance personnel did it for them, on or about July 1, 2014. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260850 E |
Issuance Date |
2014-09-11 |
Current Penalty |
4200.0 |
Initial Penalty |
7000.0 |
Final Order |
2014-10-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.850(e): It had not been determined if any type of hazardous chemicals, gases, explosives, flammable materials or similar dangerous substances had been used in any pipes, tanks, or other equipment, on the property. The presence of such substances were apparent and the hazard was not eliminated before demolition was started: a) Outside Old Production Building - No testing or purging had been completed on a 3 inch pipe, that contained residual flammable citrus oil, prior to the removal of the pipe, on or about May 24, 2014. |
|
|
315037812
|
0420600
|
2010-10-07
|
2950 GANDY BLVD., ST. PETERSBURG, FL, 33702
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2010-10-20
|
Emphasis |
N: SSTARG10, L: FOODPRO, S: ELECTRICAL, S: POWERED IND VEHICLE
|
Case Closed |
2010-10-28
|
|
314912700
|
0420600
|
2010-08-20
|
2950 GANDY BLVD., ST. PETERSBURG, FL, 33702
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2010-08-20
|
Emphasis |
S: ELECTRICAL, S: POWERED IND VEHICLE
|
Case Closed |
2010-11-23
|
Related Activity
Type |
Complaint |
Activity Nr |
207972167 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100036 D01 |
Issuance Date |
2010-08-31 |
Abatement Due Date |
2010-09-10 |
Current Penalty |
1275.0 |
Initial Penalty |
1700.0 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100037 A03 |
Issuance Date |
2010-08-31 |
Abatement Due Date |
2010-09-10 |
Current Penalty |
1275.0 |
Initial Penalty |
1700.0 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
02 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100303 G01 IA |
Issuance Date |
2010-08-31 |
Abatement Due Date |
2010-10-03 |
Current Penalty |
956.25 |
Initial Penalty |
1275.0 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
01 |
|
|
109201087
|
0420600
|
1995-03-24
|
2659 ORANGE AVE., APOPKA, FL, 32703
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1995-03-24
|
Case Closed |
1995-05-03
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100219 C02 I |
Issuance Date |
1995-04-07 |
Abatement Due Date |
1995-04-17 |
Current Penalty |
1300.0 |
Initial Penalty |
1300.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100305 G01 III |
Issuance Date |
1995-04-07 |
Abatement Due Date |
1995-04-12 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
01 |
|
|
18082792
|
0420600
|
1989-04-25
|
COUNTY LINE RD AT COCA COLA GROVE 324 BIKI, AVON PARK, FL, 33825
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1989-04-25
|
Emphasis |
N: FIELDSAN
|
Case Closed |
1989-05-09
|
|
17430315
|
0420600
|
1989-01-18
|
US 27 E. TO US 98 L/4 MI. S. THEN ON TWITTY RD., SEBRING, FL, 33870
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1989-01-18
|
Emphasis |
N: FIELDSAN
|
Case Closed |
1989-03-01
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19030002 A01 |
Issuance Date |
1989-02-13 |
Abatement Due Date |
1989-02-17 |
Nr Instances |
1 |
Nr Exposed |
23 |
|
|