Search icon

CHRISTMAS DESIGNERS, INC. - Florida Company Profile

Company Details

Entity Name: CHRISTMAS DESIGNERS, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

CHRISTMAS DESIGNERS, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 01 Nov 1979 (45 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 02 Oct 2017 (8 years ago)
Document Number: 643766
FEI/EIN Number 592013988

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2651 NE 4th Street, POMPANO BCH., FL, 33062, US
Mail Address: 2651 NE 4th Street, POMPANO BCH., FL, 33062, US
ZIP code: 33062
County: Broward
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
KEVIN LONG, LLC Agent -
LONG KEVIN President 2651 NE 4th Street, POMPANO BEACH, FL, 33062

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-02-03 2651 NE 4th Street, POMPANO BCH., FL 33062 -
CHANGE OF MAILING ADDRESS 2024-02-03 2651 NE 4th Street, POMPANO BCH., FL 33062 -
REGISTERED AGENT ADDRESS CHANGED 2024-02-03 2651 NE 4th Street, POMPANO BEACH, FL 33062 -
REINSTATEMENT 2017-10-02 - -
REGISTERED AGENT NAME CHANGED 2017-10-02 KEVIN LONG -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2017-09-22 - -

Documents

Name Date
ANNUAL REPORT 2025-02-04
ANNUAL REPORT 2024-02-03
ANNUAL REPORT 2023-02-15
ANNUAL REPORT 2022-04-04
ANNUAL REPORT 2021-02-10
ANNUAL REPORT 2020-03-12
ANNUAL REPORT 2019-04-10
ANNUAL REPORT 2018-02-16
REINSTATEMENT 2017-10-02
ANNUAL REPORT 2016-03-02

USAspending Awards. Contracts

Contract Type Award or IDV Flag PIID Start Date Current End Date Potential End Date
PO AWARD V688A01514 2010-09-15 2010-10-29 2010-10-29
Unique Award Key CONT_AWD_V688A01514_3600_-NONE-_-NONE-
Awarding Agency Department of Veterans Affairs
Link View Page

Description

Title PURCHASE OF GIFTS AND NOVELTIES
NAICS Code 453220: GIFT, NOVELTY, AND SOUVENIR STORES
Product and Service Codes 6515: MED & SURGICAL INSTRUMENTS,EQ & SUP

Recipient Details

Recipient CHRISTMAS DESIGNERS, INC.
UEI K5F3J9MDMBP9
Legacy DUNS 038076287
Recipient Address 3124 NW 16TH TER, POMPANO BEACH, 330641409, UNITED STATES
PURCHASE ORDER AWARD FA481409P0035 2008-12-08 2008-12-12 2008-12-12
Unique Award Key CONT_AWD_FA481409P0035_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 7506.00
Current Award Amount 7506.00
Potential Award Amount 7506.00

Description

Title ORNAMENTAL CANDY CANE
NAICS Code 453220: GIFT, NOVELTY, AND SOUVENIR STORES
Product and Service Codes 8345: FLAGS AND PENNANTS

Recipient Details

Recipient CHRISTMAS DESIGNERS, INC.
UEI K5F3J9MDMBP9
Legacy DUNS 038076287
Recipient Address 3124 NW 16TH TER, POMPANO BEACH, BROWARD, FLORIDA, 330641409, UNITED STATES

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342065604 0420600 2017-01-25 8551 COOPER CREEK BLVD., BRADENTON, FL, 34201
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-01-25
Emphasis L: OHPWRLNE
Case Closed 2018-05-22

Related Activity

Type Referral
Activity Nr 1176246
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100138 A
Issuance Date 2017-07-17
Abatement Due Date 2017-08-18
Current Penalty 4563.2
Initial Penalty 11408.0
Final Order 2017-08-07
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes: (a) For employees using Altec bucket trucks while removing light strands from bottle brush trees located next to 138 kV overhead power lines while using rubber gloves, on or about January 25, 2017.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100333 C03 I A 2
Issuance Date 2017-07-17
Abatement Due Date 2017-08-31
Current Penalty 4563.2
Initial Penalty 11408.0
Final Order 2017-08-07
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.333(c)(3)(i)(A)(2): When an unqualified person was working in an elevated position near overhead lines with voltages to ground rated over 50 kv, the location was not such that the person and the longest conductive object he or she could contact would not come closer to any unguarded, energized overhead line than 10 feet (305 cm) plus 4 inches (10 cm) for every 10 kV over 50 kV: (a) For employees removing Christmas lighting displays while using an Altec Aerial Bucket Truck set up near 138kv overhead power lines, on or about January 25, 2017.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100333 C03 III B
Issuance Date 2017-07-17
Abatement Due Date 2017-08-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-07
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.333(c)(3)(iii)(B): Employees standing on the ground may not contact the vehicle or mechanical equipment or any of its attachments, unless: (1) the employees are using protective equipment rated for the voltage; or (2) the equipment is located so that no uninsulated part of its structure (that portion of the structure that provides a conductive path to employees on the ground) can come closer to the line than permitted in paragraph (c)(3)(iii) of this section: (A) For employees collecting light strands on the ground below two Altec T40 Aerial Bucket Trucks that were set up by 138kv overhead power lines, on or about January 25, 2017.
Citation ID 02001
Citaton Type Other
Standard Cited 19100132 D02
Issuance Date 2017-07-17
Abatement Due Date 2017-08-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-07
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done: a) For employees removing Christmas lighting displays, on or about January 25, 2017.
341014132 0420600 2015-10-26 SHOPPES AT UNIVERSITY CENTER, UNIVERSITY PARK, FL, 34201
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2015-10-26
Emphasis L: FALL, P: FALL
Case Closed 2016-02-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2016-01-25
Current Penalty 2100.0
Initial Penalty 3500.0
Final Order 2016-02-04
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: (a) At the Shoppes at University Center where the employees that were under installing a decorative Christmas tree that was being installed were exposed to struck by hazards had no hard hats as observed on or about 10/26/2015.
312151665 0418800 2008-11-26 670 LINCOLN ROAD, MIAMI, FL, 33140
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2008-11-26
Case Closed 2009-01-13

Related Activity

Type Referral
Activity Nr 202878682
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100023 C01
Issuance Date 2008-12-19
Abatement Due Date 2008-12-24
Current Penalty 1125.0
Initial Penalty 1500.0
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
Citation ID 01002
Citaton Type Serious
Standard Cited 19100026 C03 III
Issuance Date 2008-12-19
Abatement Due Date 2008-12-24
Current Penalty 225.0
Initial Penalty 300.0
Nr Instances 1
Nr Exposed 2
Gravity 02

Date of last update: 02 Apr 2025

Sources: Florida Department of State