Search icon

INTERPLEX SUN BELT, INC. - Florida Company Profile

Company Details

Entity Name: INTERPLEX SUN BELT, INC.
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation

INTERPLEX SUN BELT, INC. is structured as a Profit Corporation, also known as a C-Corporation, a business structure recognized as a separate legal entity from its owners. This structure offers the benefit of potential tax advantages and ease of raising capital through the issuance of stock.
In Florida, Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 07 Aug 1979 (46 years ago)
Last Event: CANCEL ADM DISS/REV
Event Date Filed: 10 Oct 2007 (17 years ago)
Document Number: 632170
FEI/EIN Number 20-4142319

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 6690 Hiatus Road, Tamarac, FL 33321
Mail Address: 6690 Hiatus Road, Tamarac, FL 33321
ZIP code: 33321
County: Broward
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
Swee Har Soon, Jocelin Director 232 Pegasus Avenue, Northvale, NJ 07647
McMurray, Justin Director 6690 Hiatus Road, Tamarac, FL 33321
Sivaram, Ranjith Secretary 6690 Hiatus Road, Tamarac, FL 33321
Jeroense, Fatima Director 232 Pegasus Avenue, Northvale, NJ 07647
CORPORATION SERVICE COMPANY Agent -

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-01-30 6690 Hiatus Road, Tamarac, FL 33321 -
CHANGE OF MAILING ADDRESS 2024-01-30 6690 Hiatus Road, Tamarac, FL 33321 -
REGISTERED AGENT NAME CHANGED 2023-10-12 CORPORATION SERVICE COMPANY -
REGISTERED AGENT ADDRESS CHANGED 2023-10-12 1201 HAYS STREET, TALLAHASSEE, FL 32301 -
CANCEL ADM DISS/REV 2007-10-10 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2007-09-14 - -
CANCEL ADM DISS/REV 2006-12-19 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2006-09-15 - -
NAME CHANGE AMENDMENT 2002-06-10 INTERPLEX SUN BELT, INC. -
NAME CHANGE AMENDMENT 1997-09-15 SUN BELT INTERPLEX, INC. -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J17000180564 TERMINATED 1000000739140 BROWARD 2017-03-27 2037-03-30 $ 3,464.64 STATE OF FLORIDA, DEPARTMENT OF REVENUE, OUT OF STATE COLLECTIONS UNIT, 1415 W US HIGHWAY 90 STE 115, LAKE CITY FL320556156

Documents

Name Date
ANNUAL REPORT 2025-01-07
ANNUAL REPORT 2024-01-30
Reg. Agent Change 2023-10-12
ANNUAL REPORT 2023-04-27
ANNUAL REPORT 2022-04-14
AMENDED ANNUAL REPORT 2021-07-14
ANNUAL REPORT 2021-03-19
AMENDED ANNUAL REPORT 2020-04-20
ANNUAL REPORT 2020-03-30
AMENDED ANNUAL REPORT 2019-06-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344398615 0418800 2019-10-24 6690 HIATUS RD, TAMARAC, FL, 33321
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2020-01-29
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2020-04-20

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C05 I
Issuance Date 2020-02-26
Abatement Due Date 2020-03-04
Current Penalty 4915.8
Initial Penalty 8193.0
Final Order 2020-03-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing, or blocking of machines or equipment from energy sources: a. On or about 1/29/2020, at Interplex Sun Belt Inc., 6690 Hiatus Rd, Tamarac FL 33321. Molding department - An employee was not provided with hardware for controlling hydraulic energy while setting up and/or servicing a molding press (i.e. M-18, Nissei Model TH40-54SE), which exposed employee to a caught by hazard. b. On or about 1/29/2020, at Interplex Sun Belt Inc., 6690 Hiatus Rd, Tamarac FL 33321. Production Area - An employee was not provided with hardware for controlling energy while servicing pneumatic cylinders, which exposed employee to a caught by hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100147 C07 I A
Issuance Date 2020-02-26
Abatement Due Date 2020-03-11
Current Penalty 4915.8
Initial Penalty 8193.0
Final Order 2020-03-16
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: On or about 1/29/2020, at Interplex Sun Belt Inc., 6690 Hiatus Rd, Tamarac FL 33321. An authorized employee was not trained prior to perform servicing of pneumatic cylinders, which exposed employee to a caught by hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2020-02-26
Abatement Due Date 2020-03-20
Current Penalty 8096.4
Initial Penalty 13494.0
Final Order 2020-03-16
Nr Instances 5
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): Employees were exposed to caught by hazards where the point of operation was not guarded on machinery including but not limited to: a. On or about 10/24/2019, at Interplex Sun Belt Inc., 6690 Hiatus Rd, Tamarac FL 33321. Tool room - Employees were exposed to a caught by hazard while working with a drill press (i.e. Clausing #3, Model 2286, Serial No. 522924) that lacked a guard on its point of operation. b. On or about 10/24/2019, at Interplex Sun Belt Inc., 6690 Hiatus Rd, Tamarac FL 33321. Tool room - Employees were exposed to a caught by hazard while working with a lathe (i.e. Victor 1630, Asset M0057) that lacked a guard on its point of operation. c. On or about 1/29/2020, at Interplex Sun Belt Inc., 6690 Hiatus Rd, Tamarac FL 33321. Molding department - Employees were exposed to a caught by hazard while working with a molding press (i.e. M-14, Nissei Model TH40-54SE) whose guard did not prevent employee from reaching into the point of operation. d. On or about 1/29/2020, at Interplex Sunbelt Inc., 6690 Hiatus Rd, Tamarac FL 33321. Molding department - Employees were exposed to a caught by hazard while working with a molding press (i.e. M-19, Nissei Model TH60-2VSE, Serial No. T06V022) whose guard did not prevent employee from reaching into the point of operation. e. On or about 1/29/2020, at Interplex Sun Belt Inc., 6690 Hiatus Rd, Tamarac FL 33321. Molding department - Employees were exposed to a caught by hazard while working with a molding press (i.e. M-5, Nissei Model TH60-2VSE, Serial No. T06U011) whose guard did not prevent employee from reaching into the point of operation.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100219 C03
Issuance Date 2020-02-26
Abatement Due Date 2020-03-11
Current Penalty 2949.6
Initial Penalty 4916.0
Final Order 2020-03-16
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(c)(3): Vertical or inclined shafting seven -7 feet or less from floor or working platform was not enclosed with stationary casing(s): On or about 1/29/2020, at Interplex Sun Belt Inc., 6690 Hiatus Rd, Tamarac FL 33321. Stamping department - An employee was exposed to a caught by hazard while working in the proximity of a rewinder which had unguarded shafts.
Citation ID 02001A
Citaton Type Other
Standard Cited 19100184 C01
Issuance Date 2020-02-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-03-16
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.184(c)(1): Sling(s) that were damaged or defective were used: On or about 1/29/2020, at Interplex Sun Belt Inc., 6690 Hiatus Rd, Tamarac FL 33321. Stamping department - A worn sling used for lifting steel reels were damaged, exposing employees to a potential struck by hazard.
Citation ID 02001B
Citaton Type Other
Standard Cited 19100184 I01
Issuance Date 2020-02-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-03-16
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.184(i)(1): Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material: On or about 1/29/2020, at Interplex Sun Belt Inc., 6690 Hiatus Rd, Tamarac FL 33321. Stamping department - A worn sling used for lifting steel reels had marked rated capacities non-legible, exposing employees to a potential struck by hazard.