346956287
|
0418800
|
2023-09-05
|
246 SW 4TH AVE., HOMESTEAD, FL, 33030
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-09-05
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2023-10-31
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2023-09-29 |
Abatement Due Date |
2023-10-12 |
Current Penalty |
3984.6 |
Initial Penalty |
6641.0 |
Final Order |
2023-11-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: On or about 9/5/2023, at the jobsite located at 246 SW 4th Ave, Homestead, FL 33030, an employee was exposed to struck by and caught by hazards while working with a lathe ( i.e. Lansing Model T, Serial Number Not available) that lacked a guard on its point of operation. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2023-09-29 |
Current Penalty |
3984.6 |
Initial Penalty |
6641.0 |
Final Order |
2023-11-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: On or about 9/5/2023, at the jobsite located at 246 SW 4th Ave, Homestead, FL 33030, an employee was exposed to a struck by hazard while operating a drill press without wearing safety glasses. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
2023-09-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-11-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: On or about 9/5/2023 and at times prior, at 246 SW 4th Ave, Homestead Florida 33030, a press brake lacked of strain relief where its cord entered into the pedal, exposing an employee to an electrical hazard. |
|
|
341394674
|
0418800
|
2016-04-13
|
246 SW 4TH AVE, HOMESTEAD, FL, 33030
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-05-23
|
Emphasis |
P: AMPUTATE, N: AMPUTATE
|
Case Closed |
2017-01-18
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-18 |
Current Penalty |
2291.1 |
Initial Penalty |
3273.0 |
Final Order |
2016-07-12 |
Nr Instances |
3 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about May 23, 2016, at the interior sheet metal area of above addressed jobsite, an employee was exposed to caught and struck by hazards while working with a drill press (i.e. Northern Industrial, #066-DP06) that lacked a point of operation guard. b. On or about May 23, 2016, at the interior sheet metal area of above addressed jobsite, an employee was exposed to caught and struck by hazards while working with a drill press (i.e. RDM-100, Serial #195392) that lacked a point of operation guard. c. On or about May 23, 2016, at the interior sheet metal area of above addressed jobsite, an employee was exposed to caught and struck by hazards while working with a milling machine (i.e. Millport MP2-026) that lacked a point of operation guard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
2016-07-01 |
Current Penalty |
1124.9 |
Initial Penalty |
1607.0 |
Final Order |
2016-07-12 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving a. On or about May 23, 2016, at the interior sheet metal area of above addressed jobsite, an employee was exposed to a struck by hazard while working with a drill press (i.e. Northern Industrial, #066-DP06) which was not anchored. b. On or about May 23, 2016, at the interior sheet metal area of above addressed jobsite, an employee was exposed to a struck by hazard while working with a drill press (i.e. RDM-100, Serial #195392) which was not anchored. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100303 B02 |
Issuance Date |
2016-07-01 |
Current Penalty |
1499.4 |
Initial Penalty |
2142.0 |
Final Order |
2016-07-12 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about April 13, 2016, at the exterior welding area of above addressed jobsite, an electrical metal junction box (i.e. 4" x 4") was used as part of a job made extension cord, exposing an employee to an electrical hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100252 A01 II |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-12 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.252(a)(1)(ii): When the object to be welded or cut could not be moved and all the fire hazards could not be removed, guards were not used to confine the heat, sparks, and slag to protect the immovable fire hazards On or about May 2, 2016, at the robot welding area of the above addressed jobsite, an employee was exposed to a fire hazard while working in an area next to unguarded (i.e. cardboard boxes, wood, lubricants), located within 13 to 60 inches of a welding area. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
2016-07-01 |
Current Penalty |
375.2 |
Initial Penalty |
536.0 |
Final Order |
2016-07-12 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: On or about May 2, 2016, at the exterior sheet metal area of above addressed jobsite, an employee was exposed to an electrical hazard while operating an Ironworker (i.e. Model IW-65, #6509-24M, 2.0" punch stroke) whose foot pedal lacked strain relief, exposing interior current carrying conductors to employee contact. |
|
|
341394922
|
0418800
|
2016-04-13
|
246 SW 4TH AVE, HOMESTEAD, FL, 33030
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2016-04-13
|
Emphasis |
L: HINOISE, N: CHROME6, P: CHROME6
|
Case Closed |
2016-08-15
|
Related Activity
Type |
Referral |
Activity Nr |
1081109 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100095 C |
Issuance Date |
2016-07-27 |
Abatement Due Date |
2016-08-03 |
Current Penalty |
1260.0 |
Initial Penalty |
2100.0 |
Final Order |
2016-08-10 |
Nr Instances |
1 |
Nr Exposed |
8 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: On or about April 13th, 2016, at the jobsite located at 246 SW 4th Ave. Homestead, FL 33030, the employer did not implement an effective hearing conservation program for employees who were exposed to noise levels of 76.71% dose or an equivalent sound level of 88.0 dBA. The sampling was performed for 476 minutes and zero exposure was assumed for the un-sampled time of 4 minutes. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100095 D01 |
Issuance Date |
2016-07-27 |
Abatement Due Date |
2016-08-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-10 |
Nr Instances |
1 |
Nr Exposed |
18 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: On or about April 13th, 2016, at the jobsite located at 246 SW 4th Ave. Homestead, FL 33030, the employer did not implement a monitoring program for employees who were exposed to noise levels of 76.71% dose or an equivalent sound level of 88.0 dBA. The sampling was performed for 476 minutes and zero exposure was assumed for the un-sampled time of 4 minutes. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100095 G05 I |
Issuance Date |
2016-07-27 |
Abatement Due Date |
2016-08-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-10 |
Nr Instances |
1 |
Nr Exposed |
8 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(g)(5)(i): The employer did not establish, within 6 months of an employee's first exposure at or above the action level, a valid baseline audiogram against which subsequent audiograms can be compared: On or about April 13th, 2016, at the jobsite located at 246 SW 4th Ave. Homestead, FL 33030, the employer did not implement an effective hearing conservation program while not providing a baseline audiogram for employees who were exposed to noise levels up to 76.71% dose or an equivalent sound level of 88.0 dBA. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100132 H01 |
Issuance Date |
2016-07-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-10 |
Nr Instances |
1 |
Nr Exposed |
18 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(h)(1): Except as provided by paragraphs (h)(2) through (h)(6) of this section, the protective equipment, including personal protective equipment (PPE), used to comply with this part, was not provided by the employer at no cost to employees. On or about April 13th, 2016, at the jobsite located at 246 SW 4th Ave. Homestead, FL 33030, employer did not ensure that the required safety equipment was provided at no cost for the employees. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100134 C02 I |
Issuance Date |
2016-07-27 |
Abatement Due Date |
2016-08-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-10 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(i): The employer did not determine if the voluntary use of a respirator did not in itself create a hazard: On or about April 13th, 2016, at the jobsite located at 246 SW 4th Ave. Homestead, FL 33030, The employer did not establish and implement a written respiratory protection program using the guidance of Appendix D, and required of the employees assigned to cutting and painting operations in the warehouse to wear respiratory protection such as NIOSH approved filtering N95 facepiece Moldex respirator. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2016-07-27 |
Abatement Due Date |
2016-08-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-10 |
Nr Instances |
1 |
Nr Exposed |
18 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about April 13th, 2016, at the jobsite located at 246 SW 4th Ave. Homestead, FL 33030, the employer did not provide training for employees who are exposed to hazardous chemicals such as, but not limited to welding fumes, chromium and oxygen when performing different activities like welding and other related process, neither the information according with the Globally Harmonized System of Classification and Labeling of Chemicals with pictograms or representations as a part of the new SDS and label format. |
|
|
315354704
|
0418800
|
2011-07-12
|
246 SW 4TH AVE., HOMESTEAD, FL, 33030
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-07-12
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2012-02-01
|
Related Activity
Type |
Complaint |
Activity Nr |
207786088 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100178 P01 |
Issuance Date |
2011-09-09 |
Abatement Due Date |
2011-09-28 |
Current Penalty |
2100.0 |
Initial Penalty |
2100.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100178 Q01 |
Issuance Date |
2011-09-09 |
Abatement Due Date |
2011-09-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
|
314263419
|
0418800
|
2010-06-24
|
246 SW 4TH AVENUE, HOMESTEAD, FL, 33030
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2010-11-19
|
Case Closed |
2012-02-01
|
Related Activity
Type |
Complaint |
Activity Nr |
207777822 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2010-12-08 |
Abatement Due Date |
2011-02-21 |
Current Penalty |
875.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
25 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2010-12-08 |
Abatement Due Date |
2010-12-30 |
Current Penalty |
875.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2010-12-08 |
Abatement Due Date |
2010-12-20 |
Current Penalty |
875.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2010-12-08 |
Abatement Due Date |
2010-12-13 |
Current Penalty |
875.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100157 C01 |
Issuance Date |
2010-12-08 |
Abatement Due Date |
2010-12-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2010-12-08 |
Abatement Due Date |
2011-02-21 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
01 |
|
|