Search icon

INTERNATIONAL SHIP REPAIR COMPANY, INC. - Florida Company Profile

Company Details

Entity Name: INTERNATIONAL SHIP REPAIR COMPANY, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

INTERNATIONAL SHIP REPAIR COMPANY, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 22 Aug 1977 (48 years ago)
Date of dissolution: 10 Nov 1983 (41 years ago)
Last Event: INVOLUNTARILY DISSOLVED
Event Date Filed: 10 Nov 1983 (41 years ago)
Document Number: 546756
FEI/EIN Number 000000000

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 712 NORTHEAST SECOND AVENUE, MIAMI, FL
Mail Address: 712 NORTHEAST SECOND AVENUE, MIAMI, FL
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
HERMAN, HARRY President 712 N.E. 2ND AVENUE, MIAMI, FL
HERMAN, HARRY Director 712 N.E. 2ND AVENUE, MIAMI, FL
POLIADIS, IONNIS Vice President 712 N.E. 2ND AVENUE, MIAMI, FL
POLIADIS, IONNIS Secretary 712 N.E. 2ND AVENUE, MIAMI, FL
POLIADIS, IONNIS Director 712 N.E. 2ND AVENUE, MIAMI, FL
PEREZ, ELIZABETH Agent 712 NORTHEAST SECOND AVENUE, MIAMI, FL, 33132

Events

Event Type Filed Date Value Description
INVOLUNTARILY DISSOLVED 1983-11-10 - -

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339983850 0420600 2014-10-06 1616 PENNY STREET, TAMPA, FL, 33605
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2014-10-06
Emphasis L: EISAOF, L: EISAX
Case Closed 2015-02-06

Related Activity

Type Referral
Activity Nr 912748
Health Yes
Type Inspection
Activity Nr 996814
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19150073 C
Issuance Date 2014-11-14
Abatement Due Date 2014-11-29
Current Penalty 2700.0
Initial Penalty 4500.0
Final Order 2014-12-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1915.73(c): 29 CFR 1917.73(c): When employees were working around open hatches not protected by coamings to a height of 24 inches, or around other large openings, the edge of an opening was not guarded in the working area to a height of 36 to 42 inches. (a) At the site, on the Roll on Roll off Barge, employees were exposed to a 7 foot deep fall hazard in that the 36" x 30" floor opening was not guarded on or about 10/6/2014.
Citation ID 02001
Citaton Type Other
Standard Cited 19100134 A02
Issuance Date 2014-12-05
Abatement Due Date 2015-01-02
Current Penalty 540.0
Initial Penalty 900.0
Final Order 2014-12-15
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(a)(2): The employer did not establish and maintain a respiratory protection program which included the requirements outlined in 29 CFR 1910.134(c): (a)At facility employees perform duties, such as but not limited to MIG welding , painting and blasting and while wearing tight fitting respirators provided by employer, to protect against hazards such as but not limited to fumes, where employer does not have a respiratory protection program.
339968141 0420600 2014-09-24 1616 PENNY STREET, TAMPA, FL, 33605
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-10-06
Emphasis N: SSTARG12, P: SSTARG12, L: EISAOF, L: EISAX
Case Closed 2014-11-25

Related Activity

Type Inspection
Activity Nr 998385
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100304 E01 I
Issuance Date 2014-10-31
Current Penalty 1620.0
Initial Penalty 2700.0
Final Order 2014-11-25
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.304(e)(1)(i): Means was not provided to disconnect all conductors in a building or other structure from the service-entrance conductors. The service disconnecting means was not plainly indicated and was not readily accessible nearest the point of entrance of the service-entrance conductors: (a). At the South Slab maintenance location the 480 Volt power disconnect was blocked by the welding rod storage box preventing it from being readily accessible for emergency disconnect, on or about 25 September 2014.
Citation ID 01002
Citaton Type Serious
Standard Cited 19150159 C05
Issuance Date 2014-10-31
Current Penalty 2160.0
Initial Penalty 3600.0
Final Order 2014-11-25
Nr Instances 1
Nr Exposed 15
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1915.159(c)(5): personal fall arrest systems were not inspected prior to each use for mildew, wear, damage, and other deterioration: (a). In the equipment supply room where personal fall arrest equipment was stored and issued no inspection of the equipment harnesses was being conducted prior to use, on or about September 29, 2014.
Citation ID 02001
Citaton Type Other
Standard Cited 19100022 B01
Issuance Date 2014-10-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-11-25
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. (a). In the Maintenance Shop area a power cord used to power the shop fan laid across the walkway presenting a trip hazard where employees caring material traveled, on or about September 29, 2014.
Citation ID 02002
Citaton Type Other
Standard Cited 19100179 B05
Issuance Date 2014-10-31
Current Penalty 540.0
Initial Penalty 900.0
Final Order 2014-11-25
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.179(b)(5): Rated load marking. The rated load of the crane was not plainly marked on each side of the crane, and if the crane had more than one hoisting unit, each hoist did not have its rated load marked on it or its load block and this marking shall be clearly legible from the ground or floor. (a). At the Dry-Dock North Slab shop area, a load rate limit was not identified for the overhead crane that was being used to move small parts around the shop area at an elevated height no more than 6 feet, on or about September 29, 2014.

Date of last update: 02 Apr 2025