Search icon

PENSACOLA ROOFING COMPANY, INC. - Florida Company Profile

Company Details

Entity Name: PENSACOLA ROOFING COMPANY, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

PENSACOLA ROOFING COMPANY, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 01 Jan 1977 (48 years ago)
Date of dissolution: 25 Aug 1995 (30 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Aug 1995 (30 years ago)
Document Number: 521675
FEI/EIN Number 591736330

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 8115 MOBILE HWY, PENSACOLA, FL, 32526
Mail Address: 8115 MOBILE HWY, PENSACOLA, FL, 32526
ZIP code: 32526
County: Escambia
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
GUY, ROBERT President 218 HEWITT ST., PENSACOLA FL
GUY, PAMELA Vice President 218 HEWITT ST., PENSACOLA FL
GUY, JAMES EARL Secretary 2303 W. JORDAN ST., PENSACOLA, FL
GUY, JAMES EARL Treasurer 2303 W. JORDAN ST., PENSACOLA, FL
GUY, ROBERT Agent 8115 MOBILE HWY, PENSACOLA, FL, 32526

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 1995-08-25 - -
CHANGE OF PRINCIPAL ADDRESS 1992-09-14 8115 MOBILE HWY, PENSACOLA, FL 32526 -
CHANGE OF MAILING ADDRESS 1992-09-14 8115 MOBILE HWY, PENSACOLA, FL 32526 -
REGISTERED AGENT ADDRESS CHANGED 1992-09-14 8115 MOBILE HWY, PENSACOLA, FL 32526 -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J17000626053 LAPSED 17-225-CI-8 PINELLAS COUNTY CIRCUIT CIVIL 2017-09-28 2022-11-10 $34,004.96 GULFSIDE SUPPLY, INC. D/B/A GULFEAGLE SUPPLY, 2900 EAST 7TH AVE, TAMPA, FL 33605
J05900003385 LAPSED 04-15889-CA-27 MIAMI-DADE CIRCUIT COURT 2004-12-16 2010-02-15 $19141.24 GULFSIDE SUPPLY, INC., 501N. REO STREET, TAMPA, FL 33605
J04900000540 LAPSED 2003 CC 002608 ESCAMBIA CO CT ESCAMBIA CO FL 2003-09-29 2009-01-16 $14692.17 KAYCAN LTD., 402 BOYER CIRCLE, WILLISTON, VT 05495
J03900014132 LAPSED 2002 SC 005840 CNTY CT IN/FOR ESCAMBIA CNTY 2002-12-20 2008-10-29 $3517.50 MICHAEL SALVATORE, JR., 88 POST OFFICE BOX 4499, PENSACOLA, FL 32507

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341490563 0419700 2016-05-19 4690 ANCHOR LANE, PENSACOLA, FL, 32514
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-05-19
Emphasis L: FALL, P: FALL
Case Closed 2020-08-19

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2016-05-25
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2016-06-21
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about May 19, 2016, an employee at the jobsite was exposed to an overhead hazard, in that the employee was underneath two employees who were performing re-roofing operations without a protective helmet, exposing himself to being hit by falling debris.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2016-05-25
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2016-06-21
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about may 19, 2016, on a 4:12 pitch roof, two employees performing roofing operations were not protected from a 9-foot 6-inch fall hazard by use of a guardrail system, safety net system, personal arrest system or any alternative fall protection.
340605690 0419700 2015-05-04 1411 WILSON AVE, PENSACOLA, FL, 32503
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-05-04
Emphasis L: FALL, P: FALL
Case Closed 2020-08-19

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2015-06-12
Current Penalty 2142.0
Initial Penalty 3570.0
Final Order 2015-07-07
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about May 4, 2015, on the north side of the house, employees working on a roof installing asphalt shingles were using pneumatic nail guns and did not wear eye protection, exposing themselves to the hazard of being struck in the eye or face by flying debris.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2015-06-12
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2015-07-07
Nr Instances 2
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a. On or about May 5, 2015, on north side of a residential house on a 5/12 pitch roof, three employees installing asphalt shingles to the roof were not protected from a 8 feet 8 inch fall hazard by the use of a personal fall protection system. b. On or about May 5, 2015, on west side of a residential house on a 5/12 pitch roof, an employee installing flashing was not protected from a 10 feet fall hazard by the use of a personal fall protection system.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2015-06-12
Current Penalty 2100.0
Initial Penalty 3500.0
Final Order 2015-07-07
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. On or about May 4, 2015, on the west side of the house, the ladder used to access the porch roof did not extend 3 feet above the upper landing surface, exposing an employee to an 10 feet fall hazard.

Date of last update: 02 Apr 2025